Aqualabo

Digital PH/ORP/Redox Temperature Sensor Data Sheet

1 Datasheet : Digital sensor PHEHT Application : wastewater, drinking water, seawater, natural water MAJ : 15/11/2010 PONSEL Mesure – Group Aqualabo35 Rue Michel MARION- 58850 CAUDAN- FranceTél.: +33 (0)2.97.89.25.30- Fax :+33 (0)2.97.76.55.72 www.neotek-ponsel.com DDAATTAASSHHEEEETT Introduction : The PHEH sensor has been designed to perform under hard conditions from pure mountains water with conductivity as low as 20 µS/cm, lakes and rivers (100 – 2000 µS/cm), seawater with conductivities of 50 mS/cm and to wastewater with conductivity higher than 200 mS/cm. This sensor features a “long life” reference. The Plastogel® PONSEL technology increase the lifetime of the probe the need to refill. This sensor has been designed also for handheld and in situ applications which have been the most difficult situations for a pH/ORP sensor in term of sensor resistance, quick time response, minimal flow dependence and low power consumption. Digital Technology The “smart” pH/Redox/Temp sensor stores calibration and history data within the sensor. This allows you a “plug and play” system without re-calibration. Thanks to the Universal Modbus RS485 protocol, the PONSEL pH/Redox/T sensor can be connected to all devices commonly used (Datalogger, Controller, Automat, Remote System…). PPHHEEHHTT :: PPHH,, RREEDDOOXX && TTEEMMPPEERRAATTUURREERRAANNGGEE DDIIGGIISSEENNSS DDiiggiittaall TTeecchhnnoollooggyy ffoorr ooppttiimmiizzeedd mmeeaassuurreess ? Combination pH/Redox/Temp sensor ? Digital Sensor : Modbus RS 485 / SDI-12 ? Calibration data inside ? pH/ORP Cartridge ? Range : • pH : 0 to 14 units • Redox : - 1000 to + 1000 mV ;• T°C : -10°C to +50°C 2 Datasheet : Digital sensor PHEHT Application : wastewater, drinking water, seawater, natural water MAJ : 16/11/2009 PONSEL Mesure – Group Aqualabo35 Rue Michel Marion- 56850 CAUDAN- FranceTél.: +33 (0)2.97.89.25.30- Fax :+33 (0)2.97.76.55.72 www.neotek-ponsel.com Technical features pH Measure principle Combined electrode (pH/ref) : special glass, Ag/AgCI ref. Gelled electrolyte (KCI) Range 0 – 14 pH Resolution 0,01 pH Accuracy +/- 0,1 pH Redox Measure principle Combined electrode (Redox/reference) : Platinum tip, Ag/AgCI AgAgCl. Gelled reference (KCI) Range - 1000 to + 1000 mV Resolution 0,1 mV Accuracy ± 2 mV Temperature Technology CTN Range 0,00 °C à + 50,00°C Resolution 0,01 °C Accuracy ± 0,5 °C Response time < 5 s Storage temperature 0°C to + 60°C Protection IP 68 Interface Modbus RS-485 / SDI-12 (option) Power supply 5 to 12 volts Power consumption Standby : 25µA Average RS485 (1 measure/seconde) : 3,9 mA Average SDI12 (1 measure/seconde) : 6,8 mA Current pulse : 500 mA Sensor Dimensions Diameter : 27 / 21 mm ; Lenght : 207 mm Weight 350 g (sensor + 3 m cable) Material PVC, special pH glass, platinum Pressure 5 bars Cable Coaxial armoured, Polyurethane, bare wire or Fisher connectorProtection IP68 Dimensions Wiring diagram 1 V+ 2 SDI-12 3 V- 4 B « RS-485 » 5 A « RS-485 » 6 Cable shield Cartridge 207 mm115 mm92 mm 55 mm 21 mm 27 mm 3 Datasheet : Digital sensor PHEHT Application : wastewater, drinking water, seawater, natural water MAJ : 16/11/2009 PONSEL Mesure – Group Aqualabo35 Rue Michel Marion- 56850 CAUDAN- FranceTél.: +33 (0)2.97.89.25.30- Fax :+33 (0)2.97.76.55.72 www.neotek-ponsel.com
Most popular related searches