G2205 CRDS Analyzer Data Sheet
?e World's Leading Instruments forCarbon and Water Cycle Measurements©2012 PICARRO, INC. · 3105 Patrick Henry Drive, Santa Clara, CA 95054 · T 408.962.3900 · E [email protected] · W www.picarro.comPICARRO G2205 HF Analyzer• Superb sensitivity, precision & accuracy with virtually no drift• Fast, continuous, real time measurements without interference• Large dynamic range with high linearity• Field and laboratory deployable with no consumables• Installed and operational in minutes• Rugged and insensitive to changes in ambient temperatureAdvantage Note: The Picarro G2205 Hydrogen Fluoride Analyzer is a real time, trace gas monitor capable of measuring HF with parts-per-trillion (ppt) sensitivity. The analyzer is based on Picarro’s unique Cavity Ring Down Spectroscopy (CRDS), a time-based measurement utilizing a near-infrared laser to measure a spectral signature of the molecule. Gas is circulated in an optical measurement cavity with an effective path length of up to 20 kilometers. A patented, high-precision wavelength monitor makes certain that only the spectral feature of interest is being monitored, greatly reducing the analyzer’s sensitivity to interfering gas species, and enabling ultra-trace gas concentration measurements even if there are other gases present. As a result, the analyzer maintains high linearity, precision, and accuracy over changing environmental conditions with minimal calibration required. Precise temperature and pressure control systems designed into the Picarro G2205 ensure accurate measurements over long periods of time with minimal use of calibration gases. The analyzer is exceptionally rugged, essentially drift and maintenance free, and requires no consumables, thereby offering significant ease of use and cost of ownership benefits.Easily transportable from site to site, the analyzer can be set up and running within minutes, and require no sample preparation except drying. The gas concentration is displayed in real-time with no post-processing required, and is continuously archived to the analyzer’s internal hard drive. Designed to operate both in laboratories and in harsh environments, it can operate for many months without user interaction. The analyzer can be configured to automatically send out measurement data at regular intervals via the Ethernet or optional modem and can output real-time data in digital format (via RS-232 interface) and via optional analog outputs. Users can connect remotely with the analyzer’s internal Windows-based PC and control it through a standard Remote Desktop connection or with similar remote login software. The analyzer can also use its modem or Ethernet connection to automatically synchronize with an atomic clock time service. The software includes a valve sequencer, capable of controlling controlling up to six external solenoid valves and a rotary valve.Performance SpecificationsTarget Gas (in air-like matrix)Lower Detectable Limit* (5 min., 3s)*Guaranteed over operating conditions below, after 1-hour equilibration. H2O affects HF precision. Either dry HF or consistent H2O conc required to meet specification.Zero Drift* (24 hrs / 1 month)(peak-to-peak, 5-minute average)*Guaranteed over operating conditions belowHF 30 ppt ± 0.15 / ± 0.5 ppb?e World's Leading Instruments forCarbon and Water Cycle Measurements©2012 PICARRO, INC. · 3105 Patrick Henry Drive, Santa Clara, CA 95054 · T 408.962.3900 · E [email protected] · W www.picarro.comSystem SpecificationsMeasurement Technique CRDSMeasurement Cell Temperature Control± 0.005 °CMeasurement Cell Pressure Control± 0.0002 atmMeasurement range (at higher conc, precision will be approx 30 ppt + 0.5 % of reading)0 - 0.5 ppm specifications guaranteed; 0 - 1.0 ppm operating rangeMeasurement Interval ~ 5 secondsResponse Time 90 - 10% fall time, 0.3 ppm - 0, < 10 mins. 10 - 90% rise time, 0 - 0.3 ppm, < 10 minsSample Temperature -10 to 45 °CSample Flow Rate < 0.6 slm at 760 Torr, no filtration requiredSample Pressure 300 to 1000 Torr (40 to 133 kPa)Sample Humidity < 99% R.H. non-condensing @ 40 °C, no drying required - however, H2O affects HF measurement. Either dry HF or consistent H2O conc required for optimal performanceTemperature 10 to 35 °C (operating) -10 to 50 °C (storage)Humidity (ambient) < 99% R.H. non-condensingOther Gases Measured H2O, O2Accessories Pump (external, included), keyboard (included), mouse (included), LCD monitor (optional)Outputs RS-232, Ethernet, USB, analog (optional) 0 – 10 VFittings ¼” Swagelok® PFA fittingsDimensions Analyzer: 17.6” L x 7” h x 17” w (44.6 x 17.9 x 43.3 cm) not incl. 0.5” feetExternal Pump: 12.8” L x 8.9” h x 6.2” w (32.4 x 22.6 x 15.8 cm)Installation Benchtop or 19” rack mount chassisWeight 70 lbs (31.75 kg) including pumpPower Requirements 100 – 240 VAC, 47 – 63 Hz (auto-sensing), < 260 W start-up (total): 110 W (analyzer), 75 W (pump) at steady stateCalibration Calibration measurements for this instrument are limited by the ability to generate a constant concentration sample. The availability of commercially available standards suitable for your application should be investigated. Please contact Picarro for further information.
Most popular related searches