HYDRA Nitrate AnalyzerELECTRO-CHEMICAL DEVICESFeatures Benefits• Nitrate ISE electrode • Fast and Accurate NitrateMeasurement NO3- or NO3--N• Cl -and Temp. electrodes • Fully compensated for Cl-interferences & Temperature(Op&onal pH electrode)• Rugged PVC design • Removable electrode guardfor easy maintenance• Integral Spray Head Cleaner • Clean sensor in situ withpressurized water or air• Internal Signal Condi&oning • Amplified signals allow up to200 meters between Sensorand Analyzer HYDRA NO3-NDescrip&onThe HYDRA Nitrate Analyzer measures the concentra0on ofdissolved nitrate as nitrogen (NO3--N) in water. The sensor usestwo electrodes to determine the NO3--N concentra0on, a NitrateIon Electrode and a Chloride Ion Electrode. It is designed for usein all kinds of water. Typical applica0ons include monitoringenvironmental waters, lakes, streams and wells as well aswastewater treatment in aera0on basins and e?uent.Nitrogen primarily enters a municipal wastewater treatmentplant as ammonia/ammonium compounds. Nitri?ca0on oxidizesthe toxic ammonium ion into much less toxic nitrate ion usingan aerobic ac0vated sludge process. De-nitri?ca0on reduces thenitrate ion (NO3-) to nitrogen gas (N2) by an anoxic reac0on inthe same treatment basin or in a separate anaerobic digester.The NO3--N measurement can op0mize the methanol being fedto the digester, minimizing cost, and also provide a trend of thetotal nitrogen (TN) in the e?uent.The Nitrate Ion Electrode provides the primary measurement. Asecond electrode measures the Chloride ions in the sample. Thechloride ion due to its similar size and charge to the nitrate ion,cause a posi0ve interference in the measurement. The ChlorideIon Electrode measures the amount of chloride ion present inthe sample and HYDRA C22 Analyzer subtracts the appropriateamount of signal from the Nitrate Measurement.An op0on pH electrode is also available in the HYDRA-NO3sensor. While not required for the measurement it can providevaluable informa0on about the process. Temperature is alsomeasured and used to compensate each of the measurements.Ion electrodes tend to be less well behaved than pH electrodesso for the best results, calibrate the sensor near the processtemperature.The rugged HYDRA-NO3 sensor has a 1 ¼” NPT rear facing threadfor a1aching an extension/immersion tube for easy installa0onfrom catwalks or handrails. The HYDRA-NO3 sensor issubmersible with an IP68 degree of ingress protec0on. Aremovable electrode guard facilitates easy electrodereplacement when necessary. The HYDRA-NO3 sensor featuresinternal signal condi0oning that allows the sensor to bemounted up to 200 meters from the analyzer.The HYDRA Nitrate Analyzer displays all measurements on theHome Screen. Provides (2) 4-20 mA outputs and two AlarmRelays. It is con?gured to periodically actuate a cleaning cycleusing the integral spray cleaner in the sensor. This minimizes theforma0on of bio?lms and other coa0ngs on the electrodes,keeping maintenance to a minimum. The period and dura0onof the cleaning cycle is user con?gurable. The 4-20 mA output isheld at either the last value or a preset value during the cleaning.The HYDRA Analyzer is also available in an Ammonium, NH4+-N, Analyzer con?gura0on.Electro-Chemical Devices1681 Ke1eringIrvine, California, USA 92614Phone: +1-949-336-6060+1-800-729-1333Fax: +1-949-336-6064email: [email protected]: www.ecdi.comSpecifica?ons subject to change without no?ce.Represented by:Specifica&onsSensorSensorA Three Electrode system with spray cleaner, Nitrate ISE(NO3-- N) is the primary measurement. The Chloride ISEis used to compensate the NO3- signal. An op0onal pHelectrode is available for pH measurement. The Sensor iswaterproof with an ingress ra0ng of IP 68.Measurement RangeNO3-- N: 0.1 to 1000 ppmOpera&ng Temperature0° to 50° C (32° F to 122° F)Min/Max Flow RateMinimum 0.1 m/sMaximum 3.0 m/sWe'ed MaterialsPVC, PES, PVDF, PTFE, Viton, Glass, 316 SSAccuracy± 3% of reading, dependent on Calibra0onResponse TimeT90 1 minuteElectrode LifeISEs: 4- 6 months, typicalpH electrode: 6-12 months, typicalC22 AnalyzerMeasurementsNitrate: 0.01 to 1000 ppm as NO3-- NChloride: 0.01 to 1000 ppmpH: 0 to 14 pHTemperature: 0° to 100° C (32° F to 212° F)Compensa&onChloride: 0.1 to 1000 ppmpH: No pH compensa0onDisplay2.5” X 1.75” backlit LCD, 4 lines of Text & GraphicalEnclosureNEMA 4X, LxWxD: 5.7” x 5.7” x 7Outputs(2) 4-20 mA maximum load 800 ohms @ 24 VDCCon?gured: Ch1- 0.1 to 20 mg/l NO3-- NCh2- 0° to 100° C or 0 - 14 pHOp0onally up to (4) 4-20 mA outputs*Input Power110/220 VAC @ 50/60 HzAlarm Relay Ra&ngs(2) SPDT 230 VAC/5A or 30 VDC/5A resis0ve max.Relay(1) Spray Cleaner, Relay(2) AlarmOp0onally up to (8) Relays*HYDRA Nitrate AnalyzerPart No. Model and Product Descrip0on1290030-3 HYDRA NO3-N Sensor, complete, NO3, Cl-, pH, Temp, Spray Cleaner head and 30 ". cable1290030-4 HYDRA NO3-N Sensor, complete, NO3, Cl-, Temp, Spray Cleaner head and 30 ". cable (No pH Electrode)16LA2221.LA00 HYDRA C22 NO3-N Analyzer, Cl-, pH, (2) 4-20 mA output, 0.1 - 20 ppm NO3-N and (2) relays*16L02221.L000 HYDRA C22 NO3-N Analyzer, Cl-,(2) 4-20 mA output, 0.1 - 20 ppm NO3-N and (2) relays* (No pH Channel)Part No. Spare Parts and Accessories Descrip0on2005085.VIT Nitrate Electrode Cartridge (recommended spare)2005008.VIT Chloride Electrode Cartridge (recommended spare)2005145.VIT pH Electrode Cartridge (recommended spare)3300854-1 Replacement Spray Nozzle3501050-1 PVC Front Sensor Guard2010451 Nitrate Calibra0on solu0on, NO3-N 1 ppm2010452 Nitrate Calibra0on solu0on, NO3-N 100 ppm2010453 Chloride Calibra0on solu0on, 1 ppm2010454 Chloride Calibra0on solu0on, 100 ppm2010100 pH 4 Bu?er Calibra0on solu0on2010101 pH 7 Bu?er Calibra0on solu0onHydra-NO3 B1210HYDRA Dimensions* Consult Factory for Part# and pricing of op0onal con?gura0ons.
Most popular related searches