Flomotion Systems, Inc.
  1. Companies & Suppliers
  2. Flomotion Systems, Inc.
  3. Downloads
  4. MS1000 Electromagnetic Flowmeter Data ...

MS1000 Electromagnetic Flowmeter Data Sheet

Combines reliable full-pipe flow measurement with high accuracy, low-cost and ease of installationELECTROMAGNETIC FLOWMETERSMS1000 FEATURESMS1000· Accuracy to ±0.2% of rate from 1 to 33 ft/sec.· Lower cost than flanged units.· Twelve sizes from 1/2" to 16" Pipe Diameters.· Flow ranges from 0.85 to 19,934 GPM.· Standard pressure: 230 PSI. · Volumetric flow rate measurement independent of fluid viscosity, density and temperature.· No moving parts for zero maintenance.· Bi-directional flow measurement.· No pressure drop through sensor.· Optional integral ground electrode eliminates grounding rings with plastic piping systems.· Minimal straight pipe run required.· Every sensor is factory wet-calibrated.ELECTROMAGNETIC FLOWMETERThe MS1000 is available with Polypropylene, Ebonite or PTFE liner and local or remote mounted converter.TYPICAL APPLICATIONS· Water · Polymers· Wastewater· Lime Slurries· Dyes· Process Chemicals· Caustics· Slurries· Acids· StarchesCONTROLLER FEATURESML110 Converter ML210 Converter with Graphics Display (panel mount version)ML110 ML210Mounting Sensor or Wall Sensor, Wall or PanelKeypad 3 Internal Keys 3 KeysLCD Display 2-Line AlphanumericGraphic DisplayBacklight N Y4-20mA Output Y (opt) YPulse/Frequency/Alarm Output2 AssignableOpen Collector2 AssignableEmpty Pipe DetectionY YInterface PC, Hand Terminal RS485, PC, Hand TerminalBatch Function N YPower Supply 90-265 VAC (Std.)10-63VDC15-45VAC90-265 VAC10-35VDC18-63VDC/15-45VACEnclosure PlasticNEMA 4xAluminum or Plastic (panel version).NEMA 6ML210 Converter with Graphics Display(wall mount version)© COPYRIGHT 2012 FLOMOTION SYSTEMS INC. PGS 070112ENGINEERING SPECIFICATIONSDIMENSIONS* Hastelloy C, Platinum-Rhodium or Tantalum electrodes optional (other upon request).· Accuracy: ML210: ±0.2% of rate from 1 to 33 ft/sec. ML110: ±0.4% of rate from 1 to 33 ft/sec.· Repeatability: ±0.1%· Temperature (Process) +32 to 140°F (PP) +23 to 175°F (Ebonite) -4 to 212°F (PTFE Compact) -4 to 302°F (PTFE Remote)MS1000 Flow SensorFLOMOTION SYSTEMS Inc. 165 Creekside Drive, Suite 112Buffalo NY 14228-2103 Tel: 800-909-FLOW (3569)Tel: 716-691-3941Fax: 716-691-1253Email: [email protected] I.D. (in.) 1/2 1 1-1/2 2 3 4 6 8 10 12 14 16Min flow rate (gpm @ 1 ft/sec) 0.85 2.37 6.08 9.49 24.30 37.97 85.44 151.9 237.3 341.8 465.2 607.6Max flow rate (gpm @ 33 ft/sec) 28 77.9 199.3 311.5 797.4 1246 2803 4984 7787 11213 15262 19934Weight (lbs.) 3.5 2.7 4.0 4.4 8.4 11.0 18.1 40.1 52.9 59.5 70.6 86.0Length - L below (in.) 3.94 3.94 3.94 3.94 5.91 5.91 7.09 7.87 9.84 11.81 13.78 15.75Height - H below (in.) 6.25 5.79 6.34 6.97 8.23 9.25 11.46 14.25 16.42 18.39 20.75 22.80Outside Dia. - D below (in.) 2.48 2.21 2.76 3.39 4.65 5.67 7.87 10.67 12.84 14.80 17.17 19.21Lift Ring Distance - G (in.) - - - - - - - 5.67 7.64 9.61 11.58 13.54· Pressure: 230 PSI Std. (higher pressures upon request)· Liner Material: PTFE, Ebonite or Polypropylene· Flow Tube: 304 S.S.· Body Material: Carbon steel with two-part epoxy coating (S.S. optional)· Electrode Material: 316 S.S.*· Number of Electrodes: 2 (3rd grounding electrode optional)· Environmental Rating: NEMA 6· Fluid Conductivity: 5 µS/cm (min)· Connections: Wafer tightening between ANSI 150 flangesMS1000 Sensor
Most popular related searches