Global Treat, Inc
Scales
BUL L E T I N204 Hydraulic Chlor-Scale® 150HYDRAULIC SYSTEM REQUIRES NO POWERIT IS VIRTUALLY MAINTENANCE FREE AND IS IMMUNE TO POWER FAILURE, LIGHTNING STRIKES AND RFI/EMI.WALL MOUNTED CHAINING BRACKET INCORPORATES TOOL HOOKS TO STORE CYLINDER CHANGE- OUT TOOLS.+ SAFELY MONITOR AMOUNT USED AND REMAINING CHEMICAL+ PREVENT UNDER AND OVERFEED CONDITIONS + HYDRAULIC –– NO POWER REQUIRED+ NON-CORROSIVE PVC PLATFORM+ OPTIONAL 4-20MA OUTPUTS AND LEVEL ALARMS The CHLOR-SCALE® 150 is designed to monitor 150 lb. chlorine, sulfur dioxide and ammonia cylinders commonly used at water and wastewater treatment plants, well heads, booster stations and industrial plants. A low overall height of only 15/8"allows cylinders to be easily rolled on and off without lifting and a wall mounted chaining bracket provides the safest possible installation by securing the cylinder to the building structure itself. A Large dial indicator with convenient tare adjust knob allows easy operation and provides plant operators with critical information at a glance. Optional remote mounted indicators (up to 25') provide operators with an added level of convenience and safety by preventing unnecessary entry into the chlorine building. Because the CHLOR-SCALE 150 has an all PVC platform with corrosion resistant fasteners and fittings, you can forget about corrosion normally associated with chlorine and sweating cylinders. In addition, our incredibly simple ‘‘pivoted platform’’ design has no moving parts. This means that there are no flexures, levers or mechanical links that are susceptible to corrosion, bending or breaking. A full 5-year warranty backs each and every CHLOR-SCALE 150 including the platform, load cell and dial indicator. Buying a CHLOR-SCALE 150 means buying the bestFor Chlorine, SO2 and Ammonia CylindersWWW.FORCEFLOW.COMPERFORMAN CE G U ARANTEEDNO FINGER POINTING. NO FINE PRINT. ™™SPECIFICATIONS2430 Stanwell Drive, Concord, CA 94520 USA, PHone 925.686.6700 Fax 925.686.6713, [email protected]©2006 Force Flow. All Rights Reserved. 05/11/2006BULLETIN 204Models and Ordering InformationTypical Specification For Hydraulic Chlorine and SO2 150 lb. Cylinder ScaleOptions & Accessories Models include platform assembly, load cell with 6 feet of tubing, chaining bracket /tool rack and dial indicator. For tubing lengths over 6 feet, additional chaining brackets, 4-20ma and low-level alarms please consult factory. Metric models are available at no extra charge.®DIALB C39"to41"(990-1040)60"(1525)10" (255)AD•••PLATFORM MOUNTED LEVEL VIALPLATFORM150 LBCYLINDERSPRINGLOADEDSNAP HOOKPVC COATEDCOPPER TUBINGWALLMOUNTEDCHAININGBRACKETChlor-Scale 150 accommodates most international cylinder sizes. Example: 33kg, 68kg, 70kg, 100kg.Dimensions: Inches (Millimeters) CHLOR-SCALE 150 – FOR 150 LB. CHLORINE, SO2 & AMMONIA CYLINDERSTECHNICAL DATADisplay• 4" Century DialPlatform• Solid PVC with Tuf-Coat FinishInput• Hydraulic Load CellTare Adjustment• Tare Adjust KnobOutputs• Optional 4-20mA Output• Optional Dry Contact Level AlarmRemote Dial Mounting• Optional quick connects with additional tubing for routing through conduit or wallMODEL NUMBER DESCRIPTIONSTANDARD4D150-14D150-24D400AS METRIC4D100K-14D100K-24D200KASSingle 150 lb Cylinder Scale for Chlorine and SO2Dual 150 lb Cylinder Scale for Chlorine and SO2Single 150 lb Cylinder Scale for AmmoniaSCALE DIMENSIONS INCHES (MILLIMETERS)A13.5(345)15.75(400)MODEL NO.4D150-1, -24D100K-1, -24D400AS4D200KASB18.5(470)21.5(546)C16.5(420)18.75(476)D1.625(42)1.625(42)Cylinder scale shall be of the hydraulic cell type. Scale platform shall be constructed of non-corrosive 1inch PVC plastic and sized to accept one (1)150 lb (68kg) cylinder. A total of _____ chlorine/SO2/ammonia cylinders shall be weighed. Platform height shall be no more than 1-5/8" to allow easy loading of cylinder. Platform scale coating system shall be a minimum dry thickness of 80 mils and be resistant to moisture, chemicals, abrasion, impact and UV light.Load cell shall be of the temperature-stable, rolling diaphragm type. Flexible PVC coated copper tubing shall connect dial to load cell for easy placement of the dial and shall be _______ ft. in length (6 ft standard). Load cell system shall require no electric power and shall be immune to all RFI/EMI, power failures and lightning strikes. Cylinder chaining bracket shall be wall mounted and shall use a double coil chain and a spring loaded snap hook to secure cylinder. Chaining bracket shall have an integral tool rack for storing cylinder change-out tools.Dial diameter shall be at least 4-1/2" and read zero to 200 lbs. (100kg) net with provision for tare adjustment. Dial shall be temperature stable with damper installed to prevent shock damage during cylinder loading. Scale shall carry Full Five (5) Year Factory Warranty. “Limited” Warrantiesshall be considered unacceptable.Full scale accuracy shall be better than 1%. Scale shall be CHLOR-SCALE®150 with TUF-COATTM coating and CENTURY® dial indicator, Model 4D_____as manufactured by FORCE FLOW, 2430 Stanwell Drive, Concord, CA 94520 USA (www.forceflow.com).4-20mA TRANSMITTER (MODEL MA150)-LOOP POWERED 4-20mA TRANSMITTER FOR SCADA INTEGRATION (REQUIRES 12-45 VDC) LOW LEVEL ALARM (MODEL RS-150)- ADJUSTABLELOW LEVEL ALARM WITH 10 AMP MANUAL RESET RELAY CHAINING BRACKET (MODEL CB-10)- ADDITIONAL CYLINDER RESTRAINT BRACKETSee Bulletin 514 See Bulletin 513 See Bulletin 407SOLO XT® SOLO 1000® WIZARD 4000®www.forceflow.comSAFETYCHAINH y d r a u l i c C h l o r - S c a l e 1 5 0
Most popular related searches
