Ulpatek Air Filter Manufacturing Inc.
- Home
- Companies & Suppliers
- Ulpatek Air Filter Manufacturing Inc.
- Downloads
- Ulpatek Technical Catalogue
Ulpatek Technical Catalogue
Classification Standard EN779:2012www.ulpatek.comFilters found to have an average efficiency of 80 % or more of 0,4 µm particles will be allocated to group F (F7-F9) and the classification is based on their average efficiency (0,4 µm) as in the old system and the minimum efficiency during the test.European Association of Air Handling and Refrigerating Equipment Manufacturers, Eurovent’s certification tells our clients that Ulpatek fine filters are tested by independent research laboratory and that Ulpatek's published product information must be accurate. Ulpatek has also ISO 9001 to ensure quality operations since the day production started.ADVANCED FILTRATION FOR A BETTER FUTUREAIR FILTER TECHNOLOGY Coarse, Medium and Fine FiltersThe EN 779:2002 classification system (comprising groups F and G filters) has been changed to three groups (F-,M- and G-filters).Filters found to have an average efficiency value of less then 40 % of 0,4 µm particles will be allocated to group G and the efficiency reported as “< 40 %”. The classification of G filters (G1 - G4) is based on their average arrestance with the loading dust.Filters found to have an average efficiency value from 40 % to less than 80 % of 0,4 µm particles will be allocated to group M (M5, M6) and the classification is based on their average efficiency (0,4 µm). The filter classes F5 and F6 have changed to M5 and M6, but with same requirements, as in the old classification system.1Specifications• Easily processed • Self-extinguishing• Good uniformity and dimesional stability • Class F1/K1 according to DIN 53438• Environmental friendly • Economical• Thermobonded • SuperiSuperior dust holding capacity• Efficient • Progressive structureFilter Class; G3 - G4 Max. Operating Temperature; 75°CMedia; Synthetic Fibre Final Pressure Drop; 250 PaApplication;Fan coils, ventilation systems, air handling units and painting booths.Prefiltration of fine dust for fine and HEPA filters.Filter Type Thickness:Course (Gross) Roll Filter (mm)Filter Class (EN779)G3 G4www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREGR(g/m²)Weight Thicness 15mm T15Filter Class G3 (EN779) G3Wight (g/m²) 150 150WeightRoll Dimensions (W x L)Filter Class according to EN 779Nominal Face VelocityInitial Pressure Drop at Nominal Air FlowRecommended Final Pressure DropNominal Air Velocitymm82,515Dust Holding CapacityAverage Arrestance (Am)Thickness250137Pag%G4m³/h.m²Pam/sG31,55400581,5540040AIR FILTER TECHNOLOGY (EN779)ROLL FILTER GR-G3 GR-G4ULPATEK ROLL FILTERSGR-G3-150-T15Filter Model Roll Filter150sythetic fibre100GR250GR-G4-250-T20m°C%Temperature Resistance Maximum Relative HumidityFilter Media1489220250up to +1002x20g/m²2Specifications• Open cells polyurethane filter media • Easy to handle and install• Small transport volume • Washable• Grid at bothsides • Various frame depths with any dimensions• Various frame sizes with any dimensions • Low pressure dropStandard depth; 20 - 48mmMax. Operating Temperature; 75°CApplication; Prefilter for HVACFilter Type:Polyurethane Panel Filter:Polyurethane Z-Line FilterFrame Type Frame Depth (mm)G :Galvanized Steel 10 20 48*Other depth sizes are also availablewww.ulpatek.comPZWidht x Height (mm x mm)W x HADVANCED FILTRATION FOR A BETTER FUTUREFilter Model Pol. Panel PPFrame Type Galvanized GFrame Depth 20mm 20Filter Dimensions WxH (mm) 592x592490x592x48 2650 45PZ-G48-592x592PPPZ-G48-592x592 Polyurethane 592x592x48 3200 45PP-G20-287x287 Polyurethane 287x287x20 800 60PP-G20-287x592 Polyurethane 287x592x20 1600 60PP-G20-490x592 Polyurethane 490x592x20 2650 60Initial Pressure Drop (mm) (m³/h) (Pa)PP-G20-592x592 Polyurethane 592x592x20 3200 60Frame type; Galvanized SteelFilter Model Media MaterialDimensions WxHxD Nominal Airflow Filter Class; G2AIR FILTER TECHNOLOGY (EN779)POLYURETHANE FILTER Media; PolyurethanePP-G20-592x592PZ-G48-287x592 Polyurethane 287x592x48 1600 45PZ-G48-287x287 Polyurethane 287x287x48 800 45PZ-G48-490x592 Polyurethane1020304050607080901800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Pol type Filter P20 P483Specifications• Small transport volume• Mechanical strenght• Low pressure drop• Resistance to high temperatures• Various frame sizes with any dimensionsFilter Class; G2,G3 Application; Grease or oil mist seperationStandard depth; 20 - 48mm Frame type; Galvanized, Aluminium, Stainless SteelMedia; Expanded metal, wire mesh (Aluminium, Galvanized)Filter Type Material Type:Metal Panel Filter Expanded Metal :No mark:Metal Z-Line Filter Woven metal wire mesh : WFrame TypeG :Galvanized SteelA :Aluminium Frame Depth (mm)S :Stainless Steel 20 48Filter Class (EN779) Media Material *Other depth sizes are also availableG2 G3 G :Galvanized SteelA :AluminiumS :Stainless Steelwww.ulpatek.comG2G2G2Widht x Height (mm x mm)W x HMPG-G2-G48-592x592/WG2G2G2G2G2AluminiumAluminiumAluminiumFilter Dimensions WxH (mm)Filter Class G2592x592ADVANCED FILTRATION FOR A BETTER FUTUREMedia Material Aluminium AFrame Depth 20mm 20Material Type Expanded M. No MarkMPMZFrame TypeMPG-G2-A20-592x592Filter Model Metal Panel MPGalvanized GMPG-G2-A20-287x287 287x287x20 800Other dimensions and depth sizes are available on request.MPG-G2-A48-287x287 287x287x48 800 80AluminiumAluminium80MPG-G2-A48-592x592AluminiumMPG-G2-A20-490x592 490x592x20 2650MPG-G2-A20-287x592 287x592x20 1600MPG-G2-A48-490x592 490x592x48 2650 80MPG-G2-A48-287x592 287x592x48 1600 80AluminiumInitial Pressure Drop Media Material(mm) (m³/h) (Pa)Dimensions WxHxD Nominal Airflow 100100100100592x592x48 3200592x592x20 3200• Easy to handle and install• Multiple layers of mediaAluminiumFilter ModelMPG-G2-A20-592x592Filter ClassG2AIR FILTER TECHNOLOGY (EN779)METAL FILTER • Long service life• Long maintenance intervals1020304050607080901001101201301401800 2000 2200 2400 2600 2800 3000 3200 3400 3600 3800 4000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm G2 Metal Filter 20 484Specifications• Various frame sizes with any dimensionswww.ulpatek.com*Filter Capacity; M=Medium, H=High(EN779)• Changeable synthetic media • Easy installation• %100 hot deep galvanized frame • High dust holding capacityFilter Class; G3 - G4 Final Pressure Drop; 250 PaG3 490x592x48 2600 70G3 287x592x48 1600 70G3 592x592x48 3200 70G3 287x287x48 800AIR FILTER TECHNOLOGY (EN779)Z-LINE FILTER (G3-G4)• Simple and light weight• Grid on both sides • Long maintenance intervalsInitial Pressure Drop Nominal Airflow Dimensions WxHxD Filter Class Filter ModelMedia; Polyester Max. Operating Temperature; 75°CFrame type; Galvanized Metal Application; Prefilter for HVACStandard depth; 48 - 96mm70G4 592x592x48 3200 85GZ-G3-M48-287x287GZ-G4-M48-592x592G4 490x592x48 2600 85G4 287x592x48 1600 85GZ-G4-M48-490x592GZ-G4-M48-287x592G4 287x287x48 800 8550GZ-G4-M48-287x287GZ-G3-M96-592x592MFilter Depth 48mm50G3 287x592x96 1600 50GZ-G3-M96-490x592GZ-G3-M96-287x592Other dimensions and depth sizes are available on request.G3 490x592x96 2600ADVANCED FILTRATION FOR A BETTER FUTUREG4 490x592x96 2600 65G4 287x592x96 1600 65GZ-G4-M96-490x592GZ-G4-M96-287x592GZ-G4-M96-287x287GZ-G4-M48-592x592Filter Model Z-Line GZFilter Class G4 (EN779) G4Filter Capacity* Medium48Filter Dimensions WxH (mm) 592x592(mm) (m³/h) (Pa)GZ-G3-M48-592x592GZ-G3-M48-490x592GZ-G3-M48-287x592G4 287x287x96 800 65G3 287x287x96 800 50G4 592x592x96 3200 65GZ-G3-M96-287x287GZ-G4-M96-592x592G3 592x592x96 320001020304050607080901001101201301401501000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4250Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Z-Line Filter G3-M48 / G4-M96 G3-M96 G4-M485Specifications* Use "GRB" to define Rigid Bag model.www.ulpatek.comGB-G4-P5-490x592x600GB-G4-P3-287x592x600GB-G4-P3-287x287x600Filter Depth 360mm 360Filter Class Dimensions WxHxD Pocket QuantityNominal Airflow Initial Pressure Drop (EN779) (mm) (pcs.) (m³/h) (Pa)1700GB-G3-P5-490x592x360GB-G3-P6-592x592x360GB-G3-P3-287x592x360GB-G3-P3-287x287x360GB-G4-P6-592x592x360GB-G4-P5-490x592x360Filter Class G4 (EN779) G4Pocket Number 6 P6Filter Dimensions WxH (mm) 592x592Other dimensions and depth sizes are available on request.GB-G4-P6-592x592x360Filter Model* Bag Filter GBGB-G3-P3-287x592x600GB-G3-P3-287x592x600GB-G4-P6-592x592x600GB-G4-P3-287x592x360GB-G3-P6-592x592x600GB-G3-P5-490x592x6003030G3 490x592x600 2800 303400530G3 287x287x600 8506350G3 287x592x600G4 287x287x600 850 40G4 490x592x6003653G4 592x592x60032800340040G4 287x592x600 1700 40403400 4051700 50G3 287x287x360 850 404033490x592x36062800 50G4 592x592x360ADVANCED FILTRATION FOR A BETTER FUTUREAIR FILTER TECHNOLOGY (EN779)BAG FILTER (G3-G4)• Synthetic bags• Simple and light weight• Standard pocket filter frames28003400 50G43G4 287x287x360 850G3 287x592x36051700 40• Self-supporting pockets • Low pressure drop• Long service life• Small transport volume• Rigid bag model available (RB)G3 592x592x600• No special mechanical support requiredFrame type; Galvanized metal (25mm)Media; PolyesterFilter Class; G3 - G4 Final Pressure Drop; 250 PaMax. Operating Temperature; 75° CApplication; Prefilter for HVACG4 287x592x3603G3 490x592x3606• Easy installationGB-G4-P3-287x287x360Filter ModelG3 592x592x3600102030405060701000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4250Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Bag Filter G3-360 / G4-600 G3-600 G4-3606Specifications• Simple and light weight • Low pressure drop• No special mechanical support required • Long service life• Standard pocket filter frames • Small transport volume• Self-supporting pockets • Wide range of application area• Synthetic bags • Easy installationThe filters are used as pre- or main filter in;*Operating theatres, hospitals and air conditioning applications (HVAC)Filter Type Depth (mm):Medium Bag Filter:Fine Dust Bag Filter*Other depth sizes are also availableFilter Class (EN779)M5 F7 F9M6 F8Pocket NumberP3 P5 P8 P12P4 P6 P10www.ulpatek.comFB-F7-P8-592x592x600AIR FILTER TECHNOLOGY (EN779)S-BAG FILTER (M5-F9)Filter Class; M5 -F9 Final Pressure Drop; 450 PaMedia; Synthetic Max. Operating Temperature; 75° CFrame type; Galvanized metal (25mm) Application; Prefilter for HVACM5, F6, F7,F8, and F9 Filters are made from synthetic fibres specially designed tapered bag which allow for smooth air flow. The bags are monted air tightly into a frame made of galvanized metal, without using glue.*Industrial processes like chemical, power generation, microelectronics, pharmaceutical, the food industry, optical, microbiology, medicine etc.MB 360 560FB 460 600F8Widht x Height (mm x mm)W x HMB-M5-P6-592x592x360 FB-F8-P8-592x592x560Filter Model S-Bag Filter MB Filter Model S-Bag Filter FBFilter Class M5 (EN779) M5 Filter Class F8 (EN779)592x592Pocket Number 6 P6 Pocket Number 8 P8Filter Dimensions WxH (mm) 592x592 Filter Dimensions WxH (mm)ADVANCED FILTRATION FOR A BETTER FUTUREFilter Depth 360mm 360 Filter Depth 560mm 5607www.ulpatek.comFilter Depth 360mm 360MB-M5-P5-490x592x360MB-M5-P3-287x592x360MB-M5-P3-287x287x360MB-M6-P6-592x592x360MB-M6-P5-490x592x360MB-M6-P3-287x592x360MB-M6-P3-287x287x360MB-M5-P8-592x592x360MB-M5-P6-490x592x360MB-M5-P4-287x592x360MB-M5-P4-287x287x360MB-M6-P8-592x592x360MB-M6-P6-490x592x360MB-M6-P4-287x592x360MB-M6-P4-287x287x360FB-F7-P8-592x592x360FB-F7-P6-490x592x360FB-F7-P4-287x592x360FB-F7-P4-287x287x360FB-F8-P8-592x592x360FB-F8-P6-490x592x360FBFilter Class F7 (EN779) F7Pocket Number 8 P8Filter Dimensions WxH (mm) 592x592Other dimensions and depth sizes are available on request.FB-F7-P8-592x592x360FB-F8-P4-287x592x360FB-F8-P4-287x287x360FB-F9-P8-592x592x36040M5 287x592x360 3 1,6 1500 40M5 490x592x360 5 2,7 180040M6 592x592x360 6 3,2 2250 70AIR FILTER TECHNOLOGY (EN779)S - BAG FILTER (M5-F9; 360mm)MB-M5-P6-592x592x360 M5 592x592x360 6 3,2 2250 40Filter Class Dimensions WxHxD Pocket NumberNominal Airflow Initial Pressure Drop (EN779) (mm) (pcs.) (m³/h) (Pa)Filtration Area(m ²)Filter ModelM5 287x287x360 3 0,8 56070M6 287x592x360 3 1,6 1500 70M6 490x592x360 5 2,7 180070M5 592x592x360 8 4,2 2250 40M6 287x287x360 3 0,8 56040M5 287x592x360 4 2,1 1500 40M5 490x592x360 6 3,2 180040M6 592x592x360 8 4,2 2250 60M5 287x287x360 4 1,1 56060M6 287x592x360 4 2,1 1500 60M6 490x592x360 6 3,2 180060F7 592x592x360 8 4,2 2250 90M6 287x287x360 4 1,1 56090F7 287x592x360 4 2,1 1500 90F7 490x592x360 6 3,2 180090F8 592x592x360 8 4,2 2250 140F7 287x287x360 4 1,1 560140F8 287x592x360 4 2,1 1500 140F8 490x592x360 6 3,2 1800140F9 592x592x360 8 4,2 2250 200F8 287x287x360 4 1,1 560200ADVANCED FILTRATION FOR A BETTER FUTUREFB-F9-P4-287x287x360 F9 287x287x360 4 1,1 560200FB-F9-P4-287x592x360 F9 287x592x360 4 2,1 1500 200FB-F9-P6-490x592x360 F9 490x592x360 6 3,2 1800Filter Model Bag Filter03060901201501802102402701000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Bag Filter (360mm) M5-P6-360 M6-P6-360 F7-P8-360 F8-P8-360 F9-P8-3608www.ulpatek.com(EN779) (mm) (pcs.) (m ²) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN779)S - BAG FILTER (M5-F9; 460mm)Filter ModelFilter Class Dimensions WxHxD Pocket NumberFiltration AreaNominal Airflow Initial Pressure Drop 40MB-M5-P5-490x592x460 M5 490x592x460 5 3,4 2040 40MB-M5-P6-592x592x460 M5 592x592x460 6 4,1 255040MB-M5-P3-287x287x460 M5 287x287x460 3 1,1 635 40MB-M5-P3-287x592x460 M5 287x592x460 3 2 170065MB-M6-P5-490x592x460 M6 490x592x460 5 3,4 2040 65MB-M6-P6-592x592x460 M6 592x592x460 6 4,1 255065MB-M6-P3-287x287x460 M6 287x287x460 3 1,1 635 65MB-M6-P3-287x592x460 M6 287x592x460 3 2 170035MB-M5-P6-490x592x460 M5 490x592x460 6 4,1 2040 35MB-M5-P8-592x592x460 M5 592x592x460 8 5,4 255035MB-M5-P4-287x287x460 M5 287x287x460 4 1,4 635 35MB-M5-P4-287x592x460 M5 287x592x460 4 2,7 170055MB-M6-P6-490x592x460 M6 490x592x460 6 4,1 2040 55MB-M6-P8-592x592x460 M6 592x592x460 8 5,4 255055MB-M6-P4-287x287x460 M6 287x287x460 4 1,4 635 55MB-M6-P4-287x592x460 M6 287x592x460 4 2,7 170085FB-F7-P6-490x592x460 F7 490x592x460 6 4,1 2040 85FB-F7-P8-592x592x460 F7 592x592x460 8 5,4 255085FB-F7-P4-287x287x460 F7 287x287x460 4 1,4 635 85FB-F7-P4-287x592x460 F7 287x592x460 4 2,7 1700125FB-F8-P6-490x592x460 F8 490x592x460 6 4,1 2040 125FB-F8-P8-592x592x460 F8 592x592x460 8 5,4 2550125FB-F8-P4-287x287x460 F8 287x287x460 4 1,4 635 125FB-F8-P4-287x592x460 F8 287x592x460 4 2,7 1700180FB-F9-P6-490x592x460 F9 490x592x460 6 4,1 2040 180FB-F9-P8-592x592x460 F9 592x592x460 8 5,4 2550Other dimensions and depth sizes are available on request.FB-F8-P8-592x592x460Filter Model Bag Filter FBFilter Class F8 (EN779) F8180FB-F9-P4-287x287x460 F9 287x287x460 4 1,4 635 180FB-F9-P4-287x592x460 F9 287x592x460 4 2,7 1700Filter Depth 460mm 460ADVANCED FILTRATION FOR A BETTER FUTUREPocket Number 8 P8Filter Dimensions WxH (mm) 592x59203060901201501802102402701000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Bag Filter (460mm) M5-P6-460 M6-P6-460 F7-P8-460 F8-P8-460 F9-P8-4609www.ulpatek.com(EN779) (mm) (pcs.) (m ²) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN779)S - BAG FILTER (M5-F9; 560mm)Filter ModelFilter Class Dimensions WxHxD Pocket NumberFiltration AreaNominal Airflow Initial Pressure Drop 40MB-M5-P5-490x592x560 M5 490x592x560 5 4,1 2400 40MB-M5-P6-592x592x560 M5 592x592x560 6 4,9 300040MB-M5-P3-287x287x560 M5 287x287x560 3 1,3 750 40MB-M5-P3-287x592x560 M5 287x592x560 3 2,4 200065MB-M6-P5-490x592x560 M6 490x592x560 5 4,1 2400 65MB-M6-P6-592x592x560 M6 592x592x560 6 4,9 300065MB-M6-P3-287x287x560 M6 287x287x560 3 1,3 750 65MB-M6-P3-287x592x560 M6 287x592x560 3 2,4 200035MB-M5-P6-490x592x560 M5 490x592x560 6 4,9 2400 35MB-M5-P8-592x592x560 M5 592x592x560 8 6,5 300035MB-M5-P4-287x287x560 M5 287x287x560 4 1,7 750 35MB-M5-P4-287x592x560 M5 287x592x560 4 3,3 200055MB-M6-P6-490x592x560 M6 490x592x560 6 4,9 2400 55MB-M6-P8-592x592x560 M6 592x592x560 8 6,5 300055MB-M6-P4-287x287x560 M6 287x287x560 4 1,7 750 55MB-M6-P4-287x592x560 M6 287x592x560 4 3,3 200085FB-F7-P6-490x592x560 F7 490x592x560 6 4,9 2400 85FB-F7-P8-592x592x560 F7 592x592x560 8 6,5 300085FB-F7-P4-287x287x560 F7 287x287x560 4 1,7 750 85FB-F7-P4-287x592x560 F7 287x592x560 4 3,3 2000125FB-F8-P6-490x592x560 F8 490x592x560 6 4,9 2400 125FB-F8-P8-592x592x560 F8 592x592x560 8 6,5 3000125FB-F8-P4-287x287x560 F8 287x287x560 4 1,7 750 125FB-F8-P4-287x592x560 F8 287x592x560 4 3,3 2000180FB-F9-P6-490x592x560 F9 490x592x560 6 4,9 2400 180FB-F9-P8-592x592x560 F9 592x592x560 8 6,5 3000Other dimensions and depth sizes are available on request.FB-F9-P8-592x592x560Filter Model Bag Filter FBFilter Class F9 (EN779) F9180FB-F9-P4-287x287x560 F9 287x287x560 4 1,7 750 180FB-F9-P4-287x592x560 F9 287x592x560 4 3,3 2000Filter Depth 560mm 560ADVANCED FILTRATION FOR A BETTER FUTUREPocket Number 8 P8Filter Dimensions WxH (mm) 592x59203060901201501802102402701000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Bag Filter (560mm) M5-P6-560 M6-P6-560 F7-P8-560 F8-P8-560 F9-P8-56010SpecificationsFaceguard; Without (available on request) Sealing Compound; Two component polyurethaneGasket; Without (available on request)Filter Type Gasket:Medium Panel Filter Without :No mark:Fine Dust Panel Filter P :Pu Foam E :EPDM flatFaceguardFilter Class (EN779) Without :No markM5 F7 F9 FC :On Clean Side FB :On Both SidesM6 F8Frame TypeGalvanized Steel Frame Depth (mm)Plastic*Other depth sizes are also availablewww.ulpatek.com• Low pressure drop • Simple and light weightFilter Class; M6 - F7 - F8 - F9 Final Pressure Drop; 450 PaMedia; Glass Fibre Max. Operating Temperature; 75° C• High quality glass fibre • Easy installation• Small transport volume • Long service life• Airflow and installation in any direction possibleAIR FILTER TECHNOLOGY (EN779)PANEL FILTER (Galvanized Metal or Plastic Frame)• Large surface area • Self-supporting and rigidADVANCED FILTRATION FOR A BETTER FUTURESeperator; HotmeltFrame Type; Galvanized metal Application; Prefilter for HVACFP-F9-G48-592x592-FC/EMPFPWidht x Height (mm x mm)W x H48 96 The high quality glass fibre media used in Panel Filter supply optimum performance with suitable pleat height. The water-resistant plastic frame provides extra assurance in high-humidity applications. ULPATEK wide range of panel filters answer the demands of our customers to remove air contamination such as fine dust, smoke, vapour, soot, pollen, bacteria, etc. as prefilters or as final filters in air conditioning applications.Panel Filters are tested in accordance with European Standard EN779:2012.Panel Filters are suitable for all standard application in any efficiencies and sizes. For applications requiring increased service life, please select corresponding filters out of filter range.11MP-M6-G48-592x592MP-M6-G48-490x592MP-M6-G48-287x592MP-M6-G48-287x287FP-F7-G48-592x592FP-F7-G48-490x592FP-F7-G48-287x592FP-F7-G48-287x287FP-F8-G48-592x592FP-F8-G48-490x592FP-F8-G48-287x592FP-F8-G48-287x287FP-F9-G48-592x592FP-F9-G48-490x592FP-F9-G48-287x592FP-F9-G48-287x287www.ulpatek.comFilter Dimensions WxH (mm) 592x592ADVANCED FILTRATION FOR A BETTER FUTUREFrame Material Galvanized GFilter Depth 48mm 48Faceguard Without -Gasket Without -F9 490x592x48 5 1660 140Other dimensions and depth sizes are available on request.F9 287x592x48 3 1000 140F9 287x287x48 1,5 500 140F8 287x287x48 1,5 500 100F9 592x592x48 6 2000 140F8 490x592x48 5 1660 100F8 287x592x48 3 1000 100F7 287x287x48 1,5 500 80F8 592x592x48 6 2000 100F7 490x592x48 5 1660 80F7 287x592x48 3 1000 80M6 287x287x48 1,5 500 60F7 592x592x48 6 2000 802000 60M6 490x592x48 5 1660 60M6 287x592x48 3 1000 60M6M6 (EN779)Filter ClassMPMedium PanelFilter ModelMP-M6-G48-592x592AIR FILTER TECHNOLOGY (EN779)G - PANEL FILTER (Galvanized Metal Frame; 48mm)Nominal Airflow Initial Pressure Drop (EN779) (mm) (m ²) (m³/h) (Pa)Filter ModelFilter Class Dimensions WxHxD Filtration AreaM6 592x592x48 60204060801001201401601802002201000 1250 1500 1750 2000 2250 2500 2750 3000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm ] Panel Filter (48mm) M6 F7 F8 F912MP-M6-G96-592x592MP-M6-G96-490x592MP-M6-G96-287x592MP-M6-G96-287x287FP-F7-G96-592x592FP-F7-G96-490x592FP-F7-G96-287x592FP-F7-G96-287x287FP-F8-G96-592x592FP-F8-G96-490x592FP-F8-G96-287x592FP-F8-G96-287x287FP-F9-G96-592x592FP-F9-G96-490x592FP-F9-G96-287x592FP-F9-G96-287x287www.ulpatek.comAIR FILTER TECHNOLOGY (EN779)G - PANEL FILTER (Galvanized Metal Frame; 96mm)Nominal Airflow Initial Pressure Drop (EN779) (mm) (m ²) (m³/h) (Pa)Filter ModelFilter Class Dimensions WxHxD Filtration AreaM6 592x592x96 12 3000 70M6 490x592x96 10 2500 70M6 287x592x96 6 1500 70M6 287x287x96 3 750 70F7 592x592x96 12 3000 85F7 490x592x96 10 2500 85F7 287x592x96 6 1500 85F7 287x287x96 3 750 85F8 592x592x96 12 3000 105F8 490x592x96 10 2500 105F8 287x592x96 6 1500 105F8 287x287x96 3 750 105F9 592x592x96 12 3000 145F9 490x592x96 10 2500 145F9 287x592x96 6 1500 145F9 287x287x96 3 750 145Filter Dimensions WxH (mm) 592x592ADVANCED FILTRATION FOR A BETTER FUTUREOther dimensions and depth sizes are available on request.Frame Material Galvanized GFilter Depth 96mm 96FP-F7-G96-592x592Filter Model Fine Dust Panel FPFilter Class F7 (EN779) F7Faceguard Without -Gasket Without -0204060801001201401601802002201000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Panel Filter (96mm) M6 F7 F8 F913MP-M6-P48-592x592MP-M6-P48-490x592MP-M6-P48-287x592MP-M6-P48-287x287FP-F7-P48-592x592FP-F7-P48-490x592FP-F7-P48-287x592FP-F7-P48-287x287FP-F8-P48-592x592FP-F8-P48-490x592FP-F8-P48-287x592FP-F8-P48-287x287FP-F9-P48-592x592FP-F9-P48-490x592FP-F9-P48-287x592FP-F9-P48-287x287www.ulpatek.comAIR FILTER TECHNOLOGY (EN779)P - PANEL FILTER (Plastic Frame; 48mm)Filter ModelFilter Class Dimensions WxHxD Filtration AreaNominal Airflow Initial Pressure Drop (EN779) (mm) (m ²) (m³/h) (Pa)M6 592x592x48 6 2000 60M6 490x592x48 5 1660 60M6 287x592x48 3 1000 60M6 287x287x48 1,5 500 60F7 592x592x48 6 2000 80F7 490x592x48 5 1660 80F7 287x592x48 3 1000 80F7 287x287x48 1,5 500 80F8 592x592x48 6 2000 100F8 490x592x48 5 1660 100F8 287x592x48 3 1000 100F8 287x287x48 1,5 500 100F9 592x592x48 6 2000 140F9 490x592x48 5 1660 140F9 287x592x48 3 1000 140Filter Dimensions WxH (mm) 592x592ADVANCED FILTRATION FOR A BETTER FUTUREFrame Material Plastic PFilter Depth 48mm 48Faceguard Without -Gasket Without -FP-F8-P48-592x592Filter Model Medium Panel FPFilter Class F8 (EN779) F8F9 287x287x48 1,5 500 140Other dimensions and depth sizes are available on request.0204060801001201401601802002201000 1250 1500 1750 2000 2250 2500 2750 3000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm ] Panel Filter (48mm) M6 F7 F8 F914MP-M6-P96-592x592MP-M6-P96-490x592MP-M6-P96-287x592MP-M6-P96-287x287FP-F7-P96-592x592FP-F7-P96-490x592FP-F7-P96-287x592FP-F7-P96-287x287FP-F8-P96-592x592FP-F8-P96-490x592FP-F8-P96-287x592FP-F8-P96-287x287FP-F9-P96-592x592FP-F9-P96-490x592FP-F9-P96-287x592FP-F9-P96-287x287www.ulpatek.comAIR FILTER TECHNOLOGY (EN779)P - PANEL FILTER (Plastic Frame; 96mm)Filter ModelFilter Class Dimensions WxHxD Filtration AreaNominal Airflow Initial Pressure Drop (EN779) (mm) (m ²) (m³/h) (Pa)M6 592x592x96 12 3000 70M6 490x592x96 10 2500 70M6 287x592x96 6 1500 70M6 287x287x96 3 750 70F7 592x592x96 12 3000 85F7 490x592x96 10 2500 85F7 287x592x96 6 1500 85F7 287x287x96 3 750 85F8 592x592x96 12 3000 105F8 490x592x96 10 2500 105F8 287x592x96 6 1500 105F8 287x287x96 3 750 105F9 592x592x96 12 3000 145F9 490x592x96 10 2500 145F9 287x592x96 6 1500 145FP-F9-P96-592x592Filter Model Fine Dust Panel FPFilter Class F9 (EN779) F9F9 287x287x96 3 750 145Other dimensions and depth sizes are available on request.Filter Dimensions WxH (mm) 592x592ADVANCED FILTRATION FOR A BETTER FUTUREFrame Material Plastic PFilter Depth 96mm 96Faceguard Without -Gasket Without -0204060801001201401601802002201000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Panel Filter (96mm) M6 F7 F8 F915Specifications• Large surface area • Self-supporting and rigid• Low pressure drop • Simple and light weight• Header depths are 20 and 25mm • Easy installation• Small transport volume • Long service life• Airflow and installation in any direction possibleFaceguard; Without (available on request) Sealing Compound; Two component polyurethaneFilter Type Filter Capacity:Medium Rigid Filter No Mark :Normal:Fine Dust Rigid Filter H :High L :LowFilter Class (EN779)M5 F7 F9M6 F8Frame Type Frame DepthA :Aluminium 100mm 130mm 149mmP :Plasticwww.ulpatek.comAIR FILTER TECHNOLOGY (EN779)RIGID FILTER (Aluminium or Plastic Frame)Filter Class; M6 - F7 - F8 - F9 Final Pressure Drop; 450 PaMedia; Glass Fibre Max. Operating Temperature; 75° CFrame type; Anodized rigid aluminium Application; Prefilter for HVACADVANCED FILTRATION FOR A BETTER FUTUREDepth; 100, 130 and 149mm Seperator; HotmeltFR-F7-A130-592x592-HMRFRWidht x Height (mm x mm)W x HULPATEK wide range of Rigid filters answer the demands of our customers to remove air contamination such as fine dust, smoke, vapour, soot, pollen, bacteria, etc. as prefilters or as final filters in air conditioning applications.ULPATEK Rigid Filters offer a high dust holding capacity and long service life with optimum filtration area according to system capactiy. Fully incinerable plastic frame constructed from recycleable materials reduce its impact on the environment.Rigid Filters are suitable for all standard application in any efficiencies and sizes. For applications requiring increased service life, please select corresponding filters out of filter range.Anodized aluminium frame provides mechanical stable and strenght despite of the low weight.16* Check P100 curve for model A100.www.ulpatek.comFilter Capacity Low L Filter Capacity High HFilter Depth 130mm 130 Filter Depth 130mm 130Filter Dimensions WxH (mm) 592x592 Filter Dimensions WxH (mm) 592x592Filter Class M6 (EN779) M6 Filter Class F7 (EN779) F7Frame Material Aluminium A Frame Material Aluminium AOther dimensions are available on request.MR-M6-A130-592x592-L FR-F7-A130-592x592-HFilter Model Medium Rigid MR Filter Model Fine Dust Rigid FRF9-F9-A130-287x592-H F9 287x592x130 6,5 1500 1503000 130F8-F8-A130-287x592-H F8 287x592x130 6,5 1500 130F9-F9-A130-592x592-H F9 592x592x130 13853000 150F7-F7-A130-592x592-H F7 592x592x130 13 3000 105F7-F7-A130-287x592-H F7 287x592x130 6,5 1500 105F8-F8-A130-592x592-H F8 592x592x130 13ADVANCED FILTRATION FOR A BETTER FUTUREF9-F9-A130-287x592-L F9 287x592x130 3,3 1125 170F9-F9-A130-592x592-L F9 592x592x130 6,5 2250 170MR-M6-A130-592x592-H M6 592x592x130 13 3000 85MR-M6-A130-287x592-H M6 287x592x130 6,5 1500F8-F8-A130-287x592-L F8 287x592x130 3,3 1125 130F8-F8-A130-592x592-L F8 592x592x130 6,5 2250 130F7-F7-A130-287x592-L F7 287x592x130 3,3 1125 100F7-F7-A130-592x592-L F7 592x592x130 6,5 2250 100MR-M6-A130-287x592-L M6 287x592x130 3,3 1125 75MR-M6-A130-592x592-L M6 592x592x130 6,5 2250 75FR-F9-A100-287x592 F9 287x592x100 5 1500 170FR-F9-A100-592x592 F9 592x592x100 10 3000 170FR-F8-A100-287x592 F8 287x592x100 5 1500 150FR-F8-A100-592x592 F8 592x592x100 10 3000 150FR-F7-A100-287x592 F7 287x592x100 5 1500 125FR-F7-A100-592x592 F7 592x592x100 10 3000 125100MR-M6-A100-287x592 M6 287x592x100 5 1500 100(EN779) (mm) (m ²) (m³/h) (Pa)MR-M6-A100-592x592 M6 592x592x100 10 3000AIR FILTER TECHNOLOGY (EN779)A - RIGID FILTER (Aluminium; A100, A130L, A130H)Filter ModelFilter Class Dimensions WxHxD Filtration AreaNominal Airflow Initial Pressure Drop 0204060801001201401601802002202401000 1250 1500 1750 2000 2250 2500 2750 3000 3250Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Rijit Filter "L" (A130) M6 F7 F8 F90204060801001201401601802002201000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Rijit Filter "H" (A130) M6 F7 F8 F917www.ulpatek.comFilter Depth 149mm 149Filter Dimensions WxH (mm) 592x592Filter Capacity Standard -Filter Model Fine Dust Rigid FRFilter Class F9 (EN779) F9Frame Material Plastic PADVANCED FILTRATION FOR A BETTER FUTUREFR-F8-P100-592x592Filter Model Fine Dust Rigid FRFilter Class F8 (EN779)Filter Dimensions WxH (mm) 592x592Filter Capacity Standard -F8Frame Material Plastic PFilter Depth 100mm 100FR-F9-P149-592x592F9-F9-P149-287x592 F9 287x592x149 6,5 1500 150F9-F9-P149-592x592 F9 592x592x149 13 3000 150F8-F8-P149-287x592 F8 287x592x149 6,5 1500 130F8-F8-P149-592x592 F8 592x592x149 13 3000 130F7-F7-P149-287x592 F7 287x592x149 6,5 1500 105F7-F7-P149-592x592 F7 592x592x149 13 3000 105MR-M6-P149-287x592 M6 287x592x149 6,5 1500 85MR-M6-P149-592x592 M6 592x592x149 13 3000 85FR-F9-P100-287x592 F9 287x592x100 5 1500 170FR-F9-P100-592x592 F9 592x592x100 10 3000 170FR-F8-P100-287x592 F8 287x592x100 5 1500 150FR-F8-P100-592x592 F8 592x592x100 10 3000 150FR-F7-P100-287x592 F7 287x592x100 5 1500 125FR-F7-P100-592x592 F7 592x592x100 10 3000 125100MR-M6-P100-287x592 M6 287x592x100 5 1500 100(EN779) (mm) (m ²) (m³/h) (Pa)MR-M6-P100-592x592 M6 592x592x100 10 3000AIR FILTER TECHNOLOGY (EN779)P - RIGID FILTER (Plastic; P100, P149)Filter ModelFilter Class Dimensions WxHxD Filtration AreaNominal Airflow Initial Pressure Drop 0204060801001201401601802002201000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Rijit Filter (P149) M6 F7 F8 F90204060801001201401601802002202401000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm Rijit Filter (P100) M6 F7 F8 F918Specifications• Large filter surface • Self-supporting and rigid• Less maintenance and energy consumption • Long service life• Header depth is 25mm • Easy installation• Fully incinerable without pollutant emission • Low pressure drop• Airflow and installation in any direction possibleFinal Pressure Drop; 450 PaMax. Operating Temperature; 75° CFrame type; %100 recycled plastic frame (PP) Application; Prefilter for HVACFaceguard; Without (available on request) Seperator; HotmeltGasket; Without (available on request) Sealing Compound; Two component polyurethaneFilter TypeMV :Medium V-Compact FilterFV :Fine V-Compact FilterV-Compact Filter Type Filter Class (EN779)No mark :Standard M5 F7 F9E :Energy M6 F8T :High Temperaturewww.ulpatek.comULPATEK V-Compact Filters offer a high dust holding capacity and long service life with optimum filtration area according to system capactiy.FVE-F9-592x592x292Widht x Height x Depth (mm x mm)ADVANCED FILTRATION FOR A BETTER FUTUREW x H x DULPATEK wide range of V-Compactfilters answer the demands of our customers to remove air contamination such as fine dust, smoke, vapour, soot, pollen, bacteria, etc. as prefilters or as final filters in air conditioning applications.AIR FILTER TECHNOLOGY (EN779)V-COMPACT FILTER Filter Class; M6 - F7 - F8 - F9ULPATEK V-Compact Filters are produced with fully incinerable plastic frame constructed from recycleable materials reduce its impact on the environment and carbon emmission.Media; Glass Fibre19www.ulpatek.com175FV-F9-490x592x292 F9 490x592x292 11,5 3500 175FV-F9-287x592x292 F9 287x592x292 7 2125175FV-F8-287x592x292 F8 287x592x292 7 2125 140FV-F9-592x592x292 F9 592x592x292 14 4250140FV-F8-592x592x292 F8 592x592x292 14 4250 140FV-F8-490x592x292 F8 490x592x292 11,5 3500120FV-F7-490x592x292 F7 490x592x292 11,5 3500 120FV-F7-287x592x292 F7 287x592x292 7 2125120MV-M6-287x592x292 M6 287x592x292 7 2125 108FV-F7-592x592x292 F7 592x592x292 14 4250(EN1822) (mm) (m ²) (m³/h) (Pa)MV-M6-490x592x292 M6 490x592x292 11,5 3500V-Compact FVV-Compact Type Standard No MarkADVANCED FILTRATION FOR A BETTER FUTUREAIR FILTER TECHNOLOGY (EN779)V-COMPACT FILTER HVACFilter ModelFilter Class Dimensions WxHxD Filtration AreaNominal Airflow Initial Pressure Drop 108MV-M6-592x592x292 M6 592x592x292FV-F7-592x592x292Filter Model14 4250 108Depth D (mm) 292Filter Class F7 (EN779) F7Filter Dimensions WxH (mm) 592x5920204060801001201401601801000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4250Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm V-Compact Filter "HVAC" M6 F7 F8 F920www.ulpatek.com(EN1822) (mm) (m ²) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN779)E - V-COMPACT FILTER ENERGYFilter ModelFilter Class Dimensions WxHxD Filtration AreaNominal Airflow Initial Pressure Drop 100MVE-M6-490x592x292 M6 490x592x292 14,5 3500 100MVE-M6-592x592x292 M6 592x592x292 18 4250110MVE-M6-287x592x292 M6 287x592x292 9 2125 100FVE-F7-592x592x292 F7 592x592x292 18 4250110FVE-F7-490x592x292 F7 490x592x292 14,5 3500 110FVE-F7-287x592x292 F7 287x592x292 9 2125125FVE-F8-592x592x292 F8 592x592x292 18 4250 125FVE-F8-490x592x292 F8 490x592x292 14,5 3500145FVE-F8-287x592x292 F8 287x592x292 9 2125 125FVE-F9-592x592x292 F9 592x592x292 18 4250FVE-F9-592x592x292Filter Model V-Compact FVV-Compact Type Energy E145FVE-F9-490x592x292 F9 490x592x292 14,5 3500 145FVE-F9-287x592x292 F9 287x592x292 9 2125F9Filter Dimensions WxH (mm) 592x592ADVANCED FILTRATION FOR A BETTER FUTUREFilter Class F9 (EN779)Depth D (mm) 29201020304050607080901001101201301401501000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4250Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm V-Compact Filter "ENERGY" M6 F7 F8 F921www.ulpatek.com(EN1822) (mm) (m ²) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN779)T - V-COMPACT FILTER HIGH TEMPERATURE (up to 120°C)Filter ModelFilter Class Dimensions WxHxD Filtration AreaNominal Airflow Initial Pressure Drop 100MVT-M6-490x592x292 M6 490x592x292 14,5 3500 100MVT-M6-592x592x292 M6 592x592x292 18 4250110MVT-M6-287x592x292 M6 287x592x292 9 2125 100FVT-F7-592x592x292 F7 592x592x292 18 4250110FVT-F7-490x592x292 F7 490x592x292 14,5 3500 110FVT-F7-287x592x292 F7 287x592x292 9 2125125FVT-F8-592x592x292 F8 592x592x292 18 4250 125FVT-F8-490x592x292 F8 490x592x292 14,5 3500145FVT-F8-287x592x292 F8 287x592x292 9 2125 125FVT-F9-592x592x292 F9 592x592x292 18 4250145FVT-F9-490x592x292 F9 490x592x292 14,5 3500 145FVT-F9-287x592x292 F9 287x592x292 9 2125F8Filter Dimensions WxH (mm) 592x592ADVANCED FILTRATION FOR A BETTER FUTUREFilter Class F8 (EN779)FVT-F8-592x592x292Filter Model V-Compact FVV-Compact Type H. Temperature TDepth D (mm) 29201020304050607080901001101201301401501000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4250Initial pressure drop [Pa] Nominal Air Flow [m³/h] for 592x592mm V-Compact Filter "High Temp." M6 F7 F8 F922Classification Standard EN1822Classification Standard EN ISO 14644-1ULPATEK Leak and Efficiency Test Systemswww.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREAIR FILTER TECHNOLOGY EPA, HEPA and ULPA FiltersEfficient air filters (EPA), high efficiency air filters (HEPA) and ultra low penetration air filters (ULPA-filters) which used in the field of ventilation and air conditioning and for technical processes, e.g. for applications in clean room technology or pharmaceutical industry are classified and tested according to the EN 1822:2009 standard.ISO 14644 defines the classification of air cleanliness in cleanrooms and associated controlled environments exclusively in terms of concentration of airborne particles. Only particle populations having cumulative distributions based on threshold (lower limit) particle sizes ranging from 0.1 µm to 5 µm are considered for classification purposes.Ulpatek HEPA and ULPA filters are tested and certified individually according to European (CEN) and USA standards according to user requirements with the advanced technology. We would recommend the higher grades of prefilters to increase the service life of the Hepa and Ulpa filters. Oil Thread Test / EN1822-4 Scan Test / EN1822-4 DOP Test / ISPE 23Specifications• Optimized velocity distribution• Low pressure drop, less energy consumption• Guaranteed leak-free• Available in all grades• Various frame sizes with any dimensionsFilter Class; H13 - H14 - U15 Media; High quality glass fibreSealing Compound; Two component polyurethane Separators; HotmeltFrame type; Anodized, extruded aluminium Flammability Class; K2/F2 for normal Temp. Faceguard; Aluminium sheet (powder coated) Max. Final Pressure Drop; 600 PaGasket; EPDM flat, EPDM flat continous and PU foam Max. Operating Temperature; 75°CFilter Type Gasket (On Dirty Side)EC :EPA Ceiling Filter P :Pu Foam C :EPDM flat continousHC :HEPA Ceiling Filter E :EPDM flatUC :ULPA Ceiling Filter *Available gasket on bothsidesFilter Class (EN1822)E10 H13 U15 1 :50mm 3 :75mm 5 :90mm 7 :125mmE11 H14 U16 2 :65mm 4 :85mm 6 :100mmE12 U17Frame TypeA :Aluminium FB :Both Sides FD :Dirty SideM :MDF FC :Clean Side FW :WithoutC D K :117mmS M :100mm L :125mmN F :110mm X :150mmwww.ulpatek.comHC-H14-AS-610x610-FB/1PPleat HeightADVANCED FILTRATION FOR A BETTER FUTUREW x HFaceguardFrame Depth:66mm :90mm Widht x Height (mm x mm):69mm:78mmApplications: Industrial processes like microelectronics, medicine, pharma, the food industry, microbiology, chemistry, laboratories, hospital and hospital operating theatres, laminar flow boxes, fan filter units, nuclear energy and nuclear research.High-efficiency HEPA Ceiling filters protect people, equipment and processes from airborne particulate contamination. They are designed for clean room ceilings and cleanroom work tables requiring high or very high levels of air purity to provide laminar flow.Filtration area and pleat height designed with the optimum value are more important for performans of filters. The filters having high pleat height offer a good solution with lower operating costs and significantly reducing energy consumption.HEPA and ULPA filters are tested and certified individually according tto EN1822 with the advanced technology. We would recommend the higher grades of prefilters to increase the service life of the ceiling filters.AIR FILTER TECHNOLOGY (EN1822)HEPA/EPA/ULPA CEILING FILTER 24* For other pleat heights check the curves acc. to pleat code. www.ulpatek.comGasket type PU PADVANCED FILTRATION FOR A BETTER FUTUREFaceguard Side On Clean Side FCPleat Code PH;50mm 1* For other pleat heights check the curves acc. to pleat code. Filter Depth 78mm NFilter Dimensions WxH (mm) 610x610Filter Class E11 (EN1822) E11Frame Material Aluminium A100* Other Dimensions are available on request. EC-E11-AN-610x610-FC/1PFilter Model Epa Ceiling ECUC-E12-AN-610x1220-FC/1P E12 610x1220x78 18,0 50 1200100UC-E12-AN-610x915-FC/1P E12 610x915x78 13,5 50 900 100UC-E12-AN-610x762-FC/1P E12 610x762x78 11,2 50 750100UC-E12-AN-610x610-FC/1P E12 610x610x78 9,0 50 600 100UC-E12-AN-457x457-FC/1P E12 457x457x78 5,1 50 340100UC-E12-AN-305x610-FC/1P E12 305x610x78 4,5 50 300 100UC-E12-AN-305x305-FC/1P E12 305x305x78 2,3 50 150EC-E11-AN-610x1220-FC/1P E11 610x1220x78 18,0 50 1200 9090EC-E11-AN-610x915-FC/1P E11 610x915x78 13,5 50 90090EC-E11-AN-610x762-FC/1P E11 610x762x78 11,2 50 750 90EC-E11-AN-610x610-FC/1P E11 610x610x78 9,0 50 600EC-E11-AN-305x610-FC/1P E11 305x610x78 4,5 50 300 9090EC-E11-AN-457x457-FC/1P E11 457x457x78 5,1 50 340EC-E11-AN-305x305-FC/1P E11 305x305x78 2,3 50 150 90EC-E10-AN-610x1220-FC/1P E10 610x1220x78 18,0 50 1200 8080EC-E10-AN-610x915-FC/1P E10 610x915x78 13,5 50 90080EC-E10-AN-610x762-FC/1P E10 610x762x78 11,2 50 750 80EC-E10-AN-610x610-FC/1P E10 610x610x78 9,0 50 60080EC-E10-AN-457x457-FC/1P E10 457x457x78 5,1 50 34080EC-E10-AN-305x610-FC/1P E10 305x610x78 4,5 50 300 80EC-E10-AN-305x305-FC/1P E10 305x305x78 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)EPA CEILING FILTER with Aluminium Frame (AN;78mm - PH;50mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model4060801001201401601802000,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] EPA Ceiling Filter - Pleat Code:1 (PH50) E10 - 50mm E11 - 50mm E12 - 50mm25www.ulpatek.comGasket type PU PADVANCED FILTRATION FOR A BETTER FUTUREFaceguard Side Bothside FBPleat Code PH;50mm 1Filter Depth 66mm CFilter Dimensions WxH (mm) 610x610Filter Class U15 (EN1822) U15Frame Material Aluminium A140* Other Dimensions are available on request. UC-U15-AC-610x610-FB/1PFilter Model Ulpa Ceiling UCUC-U15-AC-610x1220-FB/1P U15 610x1220x66 20,0 50 1200140UC-U15-AC-610x915-FB/1P U15 610x915x66 15,0 50 900 140UC-U15-AC-610x762-FB/1P U15 610x762x66 12,5 50 750140UC-U15-AC-610x610-FB/1P U15 610x610x66 10,0 50 600 140UC-U15-AC-457x457-FB/1P U15 457x457x66 5,6 50 340140UC-U15-AC-305x610-FB/1P U15 305x610x66 5,0 50 300 140UC-U15-AC-305x305-FB/1P U15 305x305x66 2,5 50 150125HC-H14-AC-610x1830-FB/1P H14 610x1830x66 28,2 50 1800 125HC-H14-AC-610x1525-FB/1P H14 610x1525x66 23,5 50 1500125HC-H14-AC-610x1220-FB/1P H14 610x1220x66 18,8 50 1200 125HC-H14-AC-915x915-FB/1P H14 915x915x66 21,2 50 1350125HC-H14-AC-762x762-FB/1P H14 762x762x66 14,7 50 940 125HC-H14-AC-610x915-FB/1P H14 610x915x66 14,1 50 900125HC-H14-AC-610x762-FB/1P H14 610x762x66 11,7 50 750 125HC-H14-AC-610x610-FB/1P H14 610x610x66 9,4 50 600125HC-H14-AC-575x575-FB/1P H14 575x575x66 8,4 50 535 125HC-H14-AC-535x535-FB/1P H14 535x535x66 7,2 50 465HC-H14-AC-305x610-FB/1P H14 305x610x66 4,7 50 300 125125HC-H14-AC-457x610-FB/1P H14 457x610x66 7,0 50 450 125HC-H14-AC-457x457-FB/1P H14 457x457x66 5,3 50 340HC-H14-AC-305x305-FB/1P H14 305x305x66 2,4 50100HC-H13-AC-610x1830-FB/1P H13 610x1830x66 27,0 50 1800 100HC-H13-AC-610x1525-FB/1P H13 610x1525x66 22,5 50 1500150 125100HC-H13-AC-610x1220-FB/1P H13 610x1220x66 18,0 50 1200 100HC-H13-AC-915x915-FB/1P H13 915x915x66 20,3 50 1350100HC-H13-AC-762x762-FB/1P H13 762x762x66 14,0 50 940 100HC-H13-AC-610x915-FB/1P H13 610x915x66 13,5 50 900100HC-H13-AC-610x762-FB/1P H13 610x762x66 11,2 50 750 100HC-H13-AC-610x610-FB/1P H13 610x610x66 9,0 50 600100HC-H13-AC-575x575-FB/1P H13 575x575x66 8,0 50 535 100HC-H13-AC-535x535-FB/1P H13 535x535x66 6,9 50 465100HC-H13-AC-457x610-FB/1P H13 457x610x66 6,7 50 450 100HC-H13-AC-457x457-FB/1P H13 457x457x66 5,1 50 340100HC-H13-AC-305x610-FB/1P H13 305x610x66 4,5 50 300 100HC-H13-AC-305x305-FB/1P H13 305x305x66 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with Aluminium Frame (AC;66mm - PH;50mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model50751001251501752002252500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75Initial pressure drop [Pa] Nominal Air Velocity [m/s] Ceiling Filter - Pleat Code:1 (PH50) H13 - 50mm H14 - 50mm U15 - 50mm26www.ulpatek.comGasket type PU PADVANCED FILTRATION FOR A BETTER FUTUREFaceguard Side Bothside FBPleat Code PH;50mm 1Filter Depth 69mm SFilter Dimensions WxH (mm) 610x610Filter Class H14 (EN1822) H14Frame Material Aluminium A140* Other Dimensions are available on request. HC-H14-AS-610x610-FB/1PFilter Model Hepa Ceiling HCUC-U15-AS-610x1220-FB/1P U15 610x1220x69 20,0 50 1200140UC-U15-AS-610x915-FB/1P U15 610x915x69 15,0 50 900 140UC-U15-AS-610x762-FB/1P U15 610x762x69 12,5 50 750140UC-U15-AS-610x610-FB/1P U15 610x610x69 10,0 50 600 140UC-U15-AS-457x457-FB/1P U15 457x457x69 5,6 50 340140UC-U15-AS-305x610-FB/1P U15 305x610x69 5,0 50 300 140UC-U15-AS-305x305-FB/1P U15 305x305x69 2,5 50 150125HC-H14-AS-610x1830-FB/1P H14 610x1830x69 28,2 50 1800 125HC-H14-AS-610x1525-FB/1P H14 610x1525x69 23,5 50 1500125HC-H14-AS-610x1220-FB/1P H14 610x1220x69 18,8 50 1200 125HC-H14-AS-915x915-FB/1P H14 915x915x69 21,2 50 1350125HC-H14-AS-762x762-FB/1P H14 762x762x69 14,7 50 940 125HC-H14-AS-610x915-FB/1P H14 610x915x69 14,1 50 900125HC-H14-AS-610x762-FB/1P H14 610x762x69 11,7 50 745 125HC-H14-AS-610x610-FB/1P H14 610x610x69 9,4 50 600125HC-H14-AS-575x575-FB/1P H14 575x575x69 8,4 50 535 125HC-H14-AS-535x535-FB/1P H14 535x535x69 7,2 50 465HC-H14-AS-305x610-FB/1P H14 305x610x69 4,7 50 300 125125HC-H14-AS-457x610-FB/1P H14 457x610x69 7,0 50 450 125HC-H14-AS-457x457-FB/1P H14 457x457x69 5,3 50 340HC-H14-AS-305x305-FB/1P H14 305x305x69 2,4 50100HC-H13-AS-610x1830-FB/1P H13 610x1830x69 27,0 50 1800 100HC-H13-AS-610x1525-FB/1P H13 610x1525x69 22,5 50 1500150 125100HC-H13-AS-610x1220-FB/1P H13 610x1220x69 18,0 50 1200 100HC-H13-AS-915x915-FB/1P H13 915x915x69 20,3 50 1350100HC-H13-AS-762x762-FB/1P H13 762x762x69 14,0 50 940 100HC-H13-AS-610x915-FB/1P H13 610x915x69 13,5 50 900100HC-H13-AS-610x762-FB/1P H13 610x762x69 11,2 50 745 100HC-H13-AS-610x610-FB/1P H13 610x610x69 9,0 50 600100HC-H13-AS-575x575-FB/1P H13 575x575x69 8,0 50 535 100HC-H13-AS-535x535-FB/1P H13 535x535x69 6,9 50 465100HC-H13-AS-457x610-FB/1P H13 457x610x69 6,7 50 450 100HC-H13-AS-457x457-FB/1P H13 457x457x69 5,1 50 340100HC-H13-AS-305x610-FB/1P H13 305x610x69 4,5 50 300 100HC-H13-AS-305x305-FB/1P H13 305x305x69 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with Aluminium Frame (AS;69mm - PH;50mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model50751001251501752002252500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75Initial pressure drop [Pa] Nominal Air Velocity [m/s] Ceiling Filter - Pleat Code:1 (PH50) H13 - 50mm H14 - 50mm U15 - 50mm27www.ulpatek.comGasket type PU PADVANCED FILTRATION FOR A BETTER FUTUREFaceguard Side On Clean Side FCPleat Code PH;50mm 1Filter Depth 78mm NFilter Dimensions WxH (mm) 610x610Filter Class H14 (EN1822) H14Frame Material Aluminium A140* Other Dimensions are available on request. HC-H14-AN-610x610-FC/1PFilter Model Hepa Ceiling HCUC-U15-AN-610x1220-FC/1P U15 610x1220x78 20,0 50 1200140UC-U15-AN-610x915-FC/1P U15 610x915x78 15,0 50 900 140UC-U15-AN-610x762-FC/1P U15 610x762x78 12,5 50 750140UC-U15-AN-610x610-FC/1P U15 610x610x78 10,0 50 600 140UC-U15-AN-457x457-FC/1P U15 457x457x78 5,6 50 340140UC-U15-AN-305x610-FC/1P U15 305x610x78 5,0 50 300 140UC-U15-AN-305x305-FC/1P U15 305x305x78 2,5 50 150125HC-H14-AN-610x1830-FC/1P H14 610x1830x78 28,2 50 1800 125HC-H14-AN-610x1525-FC/1P H14 610x1525x78 23,5 50 1500125HC-H14-AN-610x1220-FC/1P H14 610x1220x78 18,8 50 1200 125HC-H14-AN-915x915-FC/1P H14 915x915x78 21,2 50 1350125HC-H14-AN-762x762-FC/1P H14 762x762x78 14,7 50 940 125HC-H14-AN-610x915-FC/1P H14 610x915x78 14,1 50 900125HC-H14-AN-610x762-FC/1P H14 610x762x78 11,7 50 750 125HC-H14-AN-610x610-FC/1P H14 610x610x78 9,4 50 600125HC-H14-AN-575x575-FC/1P H14 575x575x78 8,4 50 535 125HC-H14-AN-535x535-FC/1P H14 535x535x78 7,2 50 465HC-H14-AN-305x610-FC/1P H14 305x610x78 4,7 50 300 125125HC-H14-AN-457x610-FC/1P H14 457x610x78 7,0 50 450 125HC-H14-AN-457x457-FC/1P H14 457x457x78 5,3 50 340HC-H14-AN-305x305-FC/1P H14 305x305x78 2,4 50100HC-H13-AN-610x1830-FC/1P H13 610x1830x78 27,0 50 1800 100HC-H13-AN-610x1525-FC/1P H13 610x1525x78 22,5 50 1500150 125100HC-H13-AN-610x1220-FC/1P H13 610x1220x78 18,0 50 1200 100HC-H13-AN-915x915-FC/1P H13 915x915x78 20,3 50 1350100HC-H13-AN-762x762-FC/1P H13 762x762x78 14,0 50 940 100HC-H13-AN-610x915-FC/1P H13 610x915x78 13,5 50 900100HC-H13-AN-610x762-FC/1P H13 610x762x78 11,2 50 750 100HC-H13-AN-610x610-FC/1P H13 610x610x78 9,0 50 600100HC-H13-AN-575x575-FC/1P H13 575x575x78 8,0 50 535 100HC-H13-AN-535x535-FC/1P H13 535x535x78 6,9 50 465100HC-H13-AN-457x610-FC/1P H13 457x610x78 6,7 50 450 100HC-H13-AN-457x457-FC/1P H13 457x457x78 5,1 50 340100HC-H13-AN-305x610-FC/1P H13 305x610x78 4,5 50 300 100HC-H13-AN-305x305-FC/1P H13 305x305x78 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with Aluminium Frame (AN;78mm - PH;50mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model50751001251501752002252500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75Initial pressure drop [Pa] Nominal Air Velocity [m/s] Ceiling Filter - Pleat Code:1 (PH50) H13 - 50mm H14 - 50mm U15 - 50mm28www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;65mm 2Gasket type PU PFilter Dimensions WxH (mm) 610x610Faceguard Side Bothside FB* For other pleat heights check the curves acc. to pleat code. Frame Material Aluminium AFilter Depth 90mm D* Other Dimensions are available on request. HC-H14-AD-610x610-FB/2PFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H14110HC-H14-AD-610x1220-FB/2P H14 610x1220x90 24,4 65 1200 110HC-H14-AD-610x915-FB/2P H14 610x915x90 18,3 65 900110HC-H14-AD-610x762-FB/2P H14 610x762x90 15,3 65 750 110HC-H14-AD-610x610-FB/2P H14 610x610x90 12,2 65 600110HC-H14-AD-457x457-FB/2P H14 457x457x90 6,9 65 340 110HC-H14-AD-305x610-FB/2P H14 305x610x90 6,1 65 30085HC-H14-AD-305x305-FB/2P H14 305x305x90 3,1 65 150 110HC-H13-AD-610x1220-FB/2P H13 610x1220x90 23,4 65 120085HC-H13-AD-610x915-FB/2P H13 610x915x90 17,6 65 900 85HC-H13-AD-610x762-FB/2P H13 610x762x90 14,6 65 75085HC-H13-AD-610x610-FB/2P H13 610x610x90 11,7 65 600 85HC-H13-AD-457x457-FB/2P H13 457x457x90 6,6 65 34085HC-H13-AD-305x610-FB/2P H13 305x610x90 5,9 65 300 85HC-H13-AD-305x305-FB/2P H13 305x305x90 2,9 65 150125HC-H14-AD-610x1220-FC/1P H14 610x1220x90 18,8 50 1200 125HC-H14-AD-610x915-FC/1P H14 610x915x90 14,1 50 900125HC-H14-AD-610x762-FC/1P H14 610x762x90 11,7 50 750 125HC-H14-AD-610x610-FC/1P H14 610x610x90 9,4 50 600125HC-H14-AD-457x457-FC/1P H14 457x457x90 5,3 50 340 125HC-H14-AD-305x610-FC/1P H14 305x610x90 4,7 50 300100HC-H14-AD-305x305-FC/1P H14 305x305x90 2,4 50 150 125HC-H13-AD-610x1220-FC/1P H13 610x1220x90 18,0 50 1200100HC-H13-AD-610x915-FC/1P H13 610x915x90 13,5 50 900 100HC-H13-AD-610x762-FC/1P H13 610x762x90 11,2 50 750100HC-H13-AD-610x610-FC/1P H13 610x610x90 9,0 50 600 100HC-H13-AD-457x457-FC/1P H13 457x457x90 5,1 50 340100HC-H13-AD-305x610-FC/1P H13 305x610x90 4,5 50 300 100HC-H13-AD-305x305-FC/1P H13 305x305x90 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with Aluminium Frame (AD;90mm - PH; 50mm & 65mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model4060801001201401601802002202400,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] HEPA Ceiling Filter - Pleat Code:2 (PH65) H13 - 65mm H14 - 65mm29www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;75mm 3Gasket type PU PFilter Dimensions WxH (mm) 610x610Faceguard Side Bothside FB* For other pleat heights check the curves acc. to pleat code. Frame Material Aluminium AFilter Depth 100mm M* Other Dimensions are available on request. HC-H14-AM-610x610-FB/3PFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H1490HC-H14-AM-610x1220-FB/3P H14 610x1220x100 28,2 75 1200 90HC-H14-AM-610x915-FB/3P H14 610x915x100 21,2 75 90090HC-H14-AM-610x762-FB/3P H14 610x762x100 17,6 75 750 90HC-H14-AM-610x610-FB/3P H14 610x610x100 14,1 75 60090HC-H14-AM-457x457-FB/3P H14 457x457x100 7,9 75 340 90HC-H14-AM-305x610-FB/3P H14 305x610x100 7,1 75 30075HC-H14-AM-305x305-FB/3P H14 305x305x100 3,5 75 150 90HC-H13-AM-610x1220-FB/3P H13 610x1220x100 27,0 75 120075HC-H13-AM-610x915-FB/3P H13 610x915x100 20,3 75 900 75HC-H13-AM-610x762-FB/3P H13 610x762x100 16,9 75 75075HC-H13-AM-610x610-FB/3P H13 610x610x100 13,5 75 600 75HC-H13-AM-457x457-FB/3P H13 457x457x100 7,6 75 34075HC-H13-AM-305x610-FB/3P H13 305x610x100 6,8 75 300 75HC-H13-AM-305x305-FB/3P H13 305x305x100 3,4 75 150125HC-H14-AM-610x1220-FC/1P H14 610x1220x100 18,8 50 1200 125HC-H14-AM-610x915-FC/1P H14 610x915x100 14,1 50 900125HC-H14-AM-610x762-FC/1P H14 610x762x100 11,7 50 750 125HC-H14-AM-610x610-FC/1P H14 610x610x100 9,4 50 600125HC-H14-AM-457x457-FC/1P H14 457x457x100 5,3 50 340 125HC-H14-AM-305x610-FC/1P H14 305x610x100 4,7 50 300100HC-H14-AM-305x305-FC/1P H14 305x305x100 2,4 50 150 125HC-H13-AM-610x1220-FC/1P H13 610x1220x100 18,0 50 1200100HC-H13-AM-610x915-FC/1P H13 610x915x100 13,5 50 900 100HC-H13-AM-610x762-FC/1P H13 610x762x100 11,2 50 750100HC-H13-AM-610x610-FC/1P H13 610x610x100 9,0 50 600 100HC-H13-AM-457x457-FC/1P H13 457x457x100 5,1 50 340100HC-H13-AM-305x610-FC/1P H13 305x610x100 4,5 50 300 100HC-H13-AM-305x305-FC/1P H13 305x305x100 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with Aluminium Frame (AM;100mm - PH; 50mm & 75mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model4060801001201401601802000,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] HEPA Ceiling Filter - Pleat Code:3 (PH75) H13 - 75mm H14 - 75mm30www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;85mm 4Gasket type PU PFilter Dimensions WxH (mm) 610x610Faceguard Side Bothside FB* For other pleat heights check the curves acc. to pleat code. Frame Material Aluminium AFilter Depth 110mm FB* Other Dimensions are available on request. HC-H14-AF-610x610-FB/4PFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H1485HC-H14-AF-610x1220-FB/4P H14 610x1220x110 32,0 85 1200 85HC-H14-AF-610x915-FB/4P H14 610x915x110 24,0 85 90085HC-H14-AF-610x762-FB/4P H14 610x762x110 20,0 85 750 85HC-H14-AF-610x610-FB/4P H14 610x610x110 16,0 85 60085HC-H14-AF-457x457-FB/4P H14 457x457x110 9,0 85 340 85HC-H14-AF-305x610-FB/4P H14 305x610x110 8,0 85 30070HC-H14-AF-305x305-FB/4P H14 305x305x110 4,0 85 150 85HC-H13-AF-610x1220-FB/4P H13 610x1220x110 30,6 85 120070HC-H13-AF-610x915-FB/4P H13 610x915x110 23,0 85 900 70HC-H13-AF-610x762-FB/4P H13 610x762x110 19,1 85 75070HC-H13-AF-610x610-FB/4P H13 610x610x110 15,3 85 600 70HC-H13-AF-457x457-FB/4P H13 457x457x110 8,6 85 34070HC-H13-AF-305x610-FB/4P H13 305x610x110 7,7 85 300 70HC-H13-AF-305x305-FB/4P H13 305x305x110 3,8 85 150125HC-H14-AF-610x1220-FC/1P H14 610x1220x110 18,8 50 1200 125HC-H14-AF-610x915-FC/1P H14 610x915x110 14,1 50 900125HC-H14-AF-610x762-FC/1P H14 610x762x110 11,7 50 750 125HC-H14-AF-610x610-FC/1P H14 610x610x110 9,4 50 600125HC-H14-AF-457x457-FC/1P H14 457x457x110 5,3 50 340 125HC-H14-AF-305x610-FC/1P H14 305x610x110 4,7 50 300100HC-H14-AF-305x305-FC/1P H14 305x305x110 2,4 50 150 125HC-H13-AF-610x1220-FC/1P H13 610x1220x110 18,0 50 1200100HC-H13-AF-610x915-FC/1P H13 610x915x110 13,5 50 900 100HC-H13-AF-610x762-FC/1P H13 610x762x110 11,2 50 750100HC-H13-AF-610x610-FC/1P H13 610x610x110 9,0 50 600 100HC-H13-AF-457x457-FC/1P H13 457x457x110 5,1 50 340100HC-H13-AF-305x610-FC/1P H13 305x610x110 4,5 50 300 100HC-H13-AF-305x305-FC/1P H13 305x305x110 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with Aluminium Frame (AF;110mm - PH; 50mm & 85mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model4060801001201401601800,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] HEPA Ceiling Filter - Pleat Code:4 (PH85) H13 - 85mm H14 - 85mm31www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;90mm 5Gasket type PU PFilter Dimensions WxH (mm) 610x610Faceguard Side Bothside FB* For other pleat heights check the curves acc. to pleat code. Frame Material Aluminium AFilter Depth 117mm K* Other Dimensions are available on request. HC-H14-AK-610x610-FB/5PFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H1485HC-H14-AK-610x1220-FB/5P H14 610x1220x117 32,0 90 1200 85HC-H14-AK-610x915-FB/5P H14 610x915x117 24,0 90 90085HC-H14-AK-610x762-FB/5P H14 610x762x117 20,0 90 750 85HC-H14-AK-610x610-FB/5P H14 610x610x117 16,0 90 60085HC-H14-AK-457x457-FB/5P H14 457x457x117 9,0 90 340 85HC-H14-AK-305x610-FB/5P H14 305x610x117 8,0 90 30070HC-H14-AK-305x305-FB/5P H14 305x305x117 4,0 90 150 85HC-H13-AK-610x1220-FB/5P H13 610x1220x117 30,6 90 120070HC-H13-AK-610x915-FB/5P H13 610x915x117 23,0 90 900 70HC-H13-AK-610x762-FB/5P H13 610x762x117 19,1 90 75070HC-H13-AK-610x610-FB/5P H13 610x610x117 15,3 90 600 70HC-H13-AK-457x457-FB/5P H13 457x457x117 8,6 90 34070HC-H13-AK-305x610-FB/5P H13 305x610x117 7,7 90 300 70HC-H13-AK-305x305-FB/5P H13 305x305x117 3,8 90 150125HC-H14-AK-610x1220-FC/1P H14 610x1220x117 18,8 50 1200 125HC-H14-AK-610x915-FC/1P H14 610x915x117 14,1 50 900125HC-H14-AK-610x762-FC/1P H14 610x762x117 11,7 50 750 125HC-H14-AK-610x610-FC/1P H14 610x610x117 9,4 50 600125HC-H14-AK-457x457-FC/1P H14 457x457x117 5,3 50 340 125HC-H14-AK-305x610-FC/1P H14 305x610x117 4,7 50 300100HC-H14-AK-305x305-FC/1P H14 305x305x117 2,4 50 150 125HC-H13-AK-610x1220-FC/1P H13 610x1220x117 18,0 50 1200100HC-H13-AK-610x915-FC/1P H13 610x915x117 13,5 50 900 100HC-H13-AK-610x762-FC/1P H13 610x762x117 11,2 50 750100HC-H13-AK-610x610-FC/1P H13 610x610x117 9,0 50 600 100HC-H13-AK-457x457-FC/1P H13 457x457x117 5,1 50 340100HC-H13-AK-305x610-FC/1P H13 305x610x117 4,5 50 300 100HC-H13-AK-305x305-FC/1P H13 305x305x117 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with Aluminium Frame (AK;117mm - PH; 50mm & 90mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model4060801001201401601800,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] HEPA Ceiling Filter - Pleat Code:5 (PH90) H13 - 90mm H14 - 90mm32www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;100mm 6Gasket type PU PFilter Dimensions WxH (mm) 610x610Faceguard Side Bothside FB* For other pleat heights check the curves acc. to pleat code. Frame Material Aluminium AFilter Depth 125mm L* Other Dimensions are available on request. HC-H14-AL-610x610-FB/6PFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H1480HC-H14-AL-610x1220-FB/6P H14 610x1220x125 37,6 100 1200 80HC-H14-AL-610x915-FB/6P H14 610x915x125 28,2 100 90080HC-H14-AL-610x762-FB/6P H14 610x762x125 23,5 100 750 80HC-H14-AL-610x610-FB/6P H14 610x610x125 18,8 100 60080HC-H14-AL-457x457-FB/6P H14 457x457x125 10,6 100 340 80HC-H14-AL-305x610-FB/6P H14 305x610x125 9,4 100 30065HC-H14-AL-305x305-FB/6P H14 305x305x125 4,7 100 150 80HC-H13-AL-610x1220-FB/6P H13 610x1220x125 36,0 100 120065HC-H13-AL-610x915-FB/6P H13 610x915x125 27,0 100 900 65HC-H13-AL-610x762-FB/6P H13 610x762x125 22,5 100 75065HC-H13-AL-610x610-FB/6P H13 610x610x125 18,0 100 600 65HC-H13-AL-457x457-FB/6P H13 457x457x125 10,1 100 34065HC-H13-AL-305x610-FB/6P H13 305x610x125 9,0 100 300 65HC-H13-AL-305x305-FB/6P H13 305x305x125 4,5 100 150125HC-H14-AL-610x1220-FC/1P H14 610x1220x125 18,8 50 1200 125HC-H14-AL-610x915-FC/1P H14 610x915x125 14,1 50 900125HC-H14-AL-610x762-FC/1P H14 610x762x125 11,7 50 750 125HC-H14-AL-610x610-FC/1P H14 610x610x125 9,4 50 600125HC-H14-AL-457x457-FC/1P H14 457x457x125 5,3 50 340 125HC-H14-AL-305x610-FC/1P H14 305x610x125 4,7 50 300100HC-H14-AL-305x305-FC/1P H14 305x305x125 2,4 50 150 125HC-H13-AL-610x1220-FC/1P H13 610x1220x125 18,0 50 1200100HC-H13-AL-610x915-FC/1P H13 610x915x125 13,5 50 900 100HC-H13-AL-610x762-FC/1P H13 610x762x125 11,2 50 750100HC-H13-AL-610x610-FC/1P H13 610x610x125 9,0 50 600 100HC-H13-AL-457x457-FC/1P H13 457x457x125 5,1 50 340100HC-H13-AL-305x610-FC/1P H13 305x610x125 4,5 50 300 100HC-H13-AL-305x305-FC/1P H13 305x305x125 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with Aluminium Frame (AL;125mm - PH; 50mm & 100mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model4060801001201401601800,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] HEPA Ceiling Filter - Pleat Code:6 (PH100) H13 - 100mm H14 - 100mm33www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;125mm 7Gasket type PU PFilter Dimensions WxH (mm) 610x610Faceguard Side Bothside FB* For other pleat heights check the curves acc. to pleat code. Frame Material Aluminium AFilter Depth 150mm X* Other Dimensions are available on request. HC-H14-AX-610x610-FB/7PFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H1470HC-H14-AX-610x1220-FB/7P H14 610x1220x150 47,0 125 1200 70HC-H14-AX-610x915-FB/7P H14 610x915x150 35,3 125 90070HC-H14-AX-610x762-FB/7P H14 610x762x150 29,4 125 750 70HC-H14-AX-610x610-FB/7P H14 610x610x150 23,5 125 60070HC-H14-AX-457x457-FB/7P H14 457x457x150 13,2 125 340 70HC-H14-AX-305x610-FB/7P H14 305x610x150 11,8 125 30055HC-H14-AX-305x305-FB/7P H14 305x305x150 5,9 125 150 70HC-H13-AX-610x1220-FB/7P H13 610x1220x150 45,0 125 120055HC-H13-AX-610x915-FB/7P H13 610x915x150 33,8 125 900 55HC-H13-AX-610x762-FB/7P H13 610x762x150 28,1 125 75055HC-H13-AX-610x610-FB/7P H13 610x610x150 22,5 125 600 55HC-H13-AX-457x457-FB/7P H13 457x457x150 12,6 125 34055HC-H13-AX-305x610-FB/7P H13 305x610x150 11,3 125 300 55HC-H13-AX-305x305-FB/7P H13 305x305x150 5,6 125 150125HC-H14-AX-610x1220-FC/1P H14 610x1220x150 18,8 50 1200 125HC-H14-AX-610x915-FC/1P H14 610x915x150 14,1 50 900125HC-H14-AX-610x762-FC/1P H14 610x762x150 11,7 50 750 125HC-H14-AX-610x610-FC/1P H14 610x610x150 9,4 50 600125HC-H14-AX-457x457-FC/1P H14 457x457x150 5,3 50 340 125HC-H14-AX-305x610-FC/1P H14 305x610x150 4,7 50 300100HC-H14-AX-305x305-FC/1P H14 305x305x150 2,4 50 150 125HC-H13-AX-610x1220-FC/1P H13 610x1220x150 18,0 50 1200100HC-H13-AX-610x915-FC/1P H13 610x915x150 13,5 50 900 100HC-H13-AX-610x762-FC/1P H13 610x762x150 11,2 50 750100HC-H13-AX-610x610-FC/1P H13 610x610x150 9,0 50 600 100HC-H13-AX-457x457-FC/1P H13 457x457x150 5,1 50 340100HC-H13-AX-305x610-FC/1P H13 305x610x150 4,5 50 300 100HC-H13-AX-305x305-FC/1P H13 305x305x150 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with Aluminium Frame (AX;150mm - PH; 50mm & 125mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model30456075901051201351500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] HEPA Ceiling Filter - Pleat Code:7 (PH125) H13 - 125mm H14 - 125mm34www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;50mm 1Gasket type PU PFilter Dimensions WxH (mm) 610x610Faceguard Side Without FWFrame Material MDF MFilter Depth 78mm N* Other Dimensions are available on request. HC-H13-MN-610x610-FW/1PFilter Model Hepa Ceiling HCFilter Class H13 (EN1822) H13125HC-H14-MN-610x1830-FW/1P H14 610x1830x78 28,2 50 1800 125HC-H14-MN-610x1525-FW/1P H14 610x1525x78 23,5 50 1500125HC-H14-MN-610x1220-FW/1P H14 610x1220x78 18,8 50 1200 125HC-H14-MN-915x915-FW/1P H14 915x915x78 21,2 50 1350125HC-H14-MN-762x762-FW/1P H14 762x762x78 14,7 50 940 125HC-H14-MN-610x915-FW/1P H14 610x915x78 14,1 50 900125HC-H14-MN-610x762-FW/1P H14 610x762x78 11,7 50 750 125HC-H14-MN-610x610-FW/1P H14 610x610x78 9,4 50 600125HC-H14-MN-575x575-FW/1P H14 575x575x78 8,4 50 535 125HC-H14-MN-535x535-FW/1P H14 535x535x78 7,2 50 465HC-H14-MN-305x610-FW/1P H14 305x610x78 4,7 50 300 125125HC-H14-MN-457x610-FW/1P H14 457x610x78 7,0 50 450 125HC-H14-MN-457x457-FW/1P H14 457x457x78 5,3 50 340HC-H14-MN-305x305-FW/1P H14 305x305x78 2,4 50100HC-H13-MN-610x1830-FW/1P H13 610x1830x78 27,0 50 1800 100HC-H13-MN-610x1525-FW/1P H13 610x1525x78 22,5 50 1500150 125100HC-H13-MN-610x1220-FW/1P H13 610x1220x78 18,0 50 1200 100HC-H13-MN-915x915-FW/1P H13 915x915x78 20,3 50 1350100HC-H13-MN-762x762-FW/1P H13 762x762x78 14,0 50 940 100HC-H13-MN-610x915-FW/1P H13 610x915x78 13,5 50 900100HC-H13-MN-610x762-FW/1P H13 610x762x78 11,2 50 750 100HC-H13-MN-610x610-FW/1P H13 610x610x78 9,0 50 600100HC-H13-MN-575x575-FW/1P H13 575x575x78 8,0 50 535 100HC-H13-MN-535x535-FW/1P H13 535x535x78 6,9 50 465100HC-H13-MN-457x610-FW/1P H13 457x610x78 6,7 50 450 100HC-H13-MN-457x457-FW/1P H13 457x457x78 5,1 50 340100HC-H13-MN-305x610-FW/1P H13 305x610x78 4,5 50 300 100HC-H13-MN-305x305-FW/1P H13 305x305x78 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA CEILING FILTER with MDF Frame (MN;78mm - PH;50mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model50751001251501752002252500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75Initial pressure drop [Pa] Nominal Air Velocity [m/s] HEPA Ceiling Filter - Pleat Code:1 (PH50) H13 - 50mm H14 - 50mm35* For other pleat heights check the curves acc. to pleat code. www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;50mm 1Gasket type PU PFilter Dimensions WxH (mm) 610x610Faceguard Side Without FWFrame Material MDF MFilter Depth 150mm X* Other Dimensions are available on request. HC-H13-MX-610x610-FW/1PFilter Model Hepa Ceiling HCFilter Class H13 (EN1822) H13125HC-H14-MX-610x1830-FW/1P H14 610x1830x150 28,2 50 1800 125HC-H14-MX-610x1525-FW/1P H14 610x1525x150 23,5 50 1500125HC-H14-MX-610x1220-FW/1P H14 610x1220x150 18,8 50 1200 125HC-H14-MX-915x915-FW/1P H14 915x915x150 21,2 50 1350125HC-H14-MX-762x762-FW/1P H14 762x762x150 14,7 50 940 125HC-H14-MX-610x915-FW/1P H14 610x915x150 14,1 50 900125HC-H14-MX-610x762-FW/1P H14 610x762x150 11,7 50 750 125HC-H14-MX-610x610-FW/1P H14 610x610x150 9,4 50 600125HC-H14-MX-575x575-FW/1P H14 575x575x150 8,4 50 535 125HC-H14-MX-535x535-FW/1P H14 535x535x150 7,2 50 465HC-H14-MX-305x610-FW/1P H14 305x610x150 4,7 50 300 125125HC-H14-MX-457x610-FW/1P H14 457x610x150 7,0 50 450 125HC-H14-MX-457x457-FW/1P H14 457x457x150 5,3 50 340HC-H14-MX-305x305-FW/1P H14 305x305x150 2,4 50100HC-H13-MX-610x1830-FW/1P H13 610x1830x150 27,0 50 1800 100HC-H13-MX-610x1525-FW/1P H13 610x1525x150 22,5 50 1500150 125100HC-H13-MX-610x1220-FW/1P H13 610x1220x150 18,0 50 1200 100HC-H13-MX-915x915-FW/1P H13 915x915x150 20,3 50 1350100HC-H13-MX-762x762-FW/1P H13 762x762x150 14,0 50 940 100HC-H13-MX-610x915-FW/1P H13 610x915x150 13,5 50 900100HC-H13-MX-610x762-FW/1P H13 610x762x150 11,2 50 750 100HC-H13-MX-610x610-FW/1P H13 610x610x150 9,0 50 600100HC-H13-MX-575x575-FW/1P H13 575x575x150 8,0 50 535 100HC-H13-MX-535x535-FW/1P H13 535x535x150 6,9 50 465100HC-H13-MX-457x610-FW/1P H13 457x610x150 6,7 50 450 100HC-H13-MX-457x457-FW/1P H13 457x457x150 5,1 50 340100HC-H13-MX-305x610-FW/1P H13 305x610x150 4,5 50 300 100HC-H13-MX-305x305-FW/1P H13 305x305x150 2,3 50 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA CEILING FILTER with MDF Frame (MX;150mm - PH;50mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model50751001251501752002252500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75Initial pressure drop [Pa] Nominal Air Velocity [m/s] HEPA Ceiling Filter - Pleat Code:1 (PH50) H13 - 50mm H14 - 50mm36* For other pleat heights check the curves acc. to pleat code. www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;125mm 7Gasket type PU PFilter Dimensions WxH (mm) 610x610Faceguard Side Without FWFrame Material MDF MFilter Depth 150mm X* Other Dimensions are available on request. HC-H13-MX-610x610-FW/7PFilter Model Hepa Ceiling HCFilter Class H13 (EN1822) H1380HC-H14-MX-610x1830-FW/7P H14 610x1830x150 56,4 125 1800 80HC-H14-MX-610x1525-FW/7P H14 610x1525x150 47,0 125 150080HC-H14-MX-610x1220-FW/7P H14 610x1220x150 37,6 125 1200 80HC-H14-MX-915x915-FW/7P H14 915x915x150 42,3 125 135080HC-H14-MX-762x762-FW/7P H14 762x762x150 29,3 125 940 80HC-H14-MX-610x915-FW/7P H14 610x915x150 28,2 125 90080HC-H14-MX-610x762-FW/7P H14 610x762x150 23,5 125 750 80HC-H14-MX-610x610-FW/7P H14 610x610x150 18,8 125 60080HC-H14-MX-575x575-FW/7P H14 575x575x150 16,7 125 535 80HC-H14-MX-535x535-FW/7P H14 535x535x150 14,5 125 465HC-H14-MX-305x610-FW/7P H14 305x610x150 9,4 125 300 8080HC-H14-MX-457x610-FW/7P H14 457x610x150 14,1 125 450 80HC-H14-MX-457x457-FW/7P H14 457x457x150 10,6 125 340HC-H14-MX-305x305-FW/7P H14 305x305x150 4,7 12565HC-H13-MX-610x1830-FW/7P H13 610x1830x150 54,0 125 1800 65HC-H13-MX-610x1525-FW/7P H13 610x1525x150 45,0 125 1500150 8065HC-H13-MX-610x1220-FW/7P H13 610x1220x150 36,0 125 1200 65HC-H13-MX-915x915-FW/7P H13 915x915x150 40,5 125 135065HC-H13-MX-762x762-FW/7P H13 762x762x150 28,1 125 940 65HC-H13-MX-610x915-FW/7P H13 610x915x150 27,0 125 90065HC-H13-MX-610x762-FW/7P H13 610x762x150 22,5 125 750 65HC-H13-MX-610x610-FW/7P H13 610x610x150 18,0 125 60065HC-H13-MX-575x575-FW/7P H13 575x575x150 16,0 125 535 65HC-H13-MX-535x535-FW/7P H13 535x535x150 13,9 125 46565HC-H13-MX-457x610-FW/7P H13 457x610x150 13,5 125 450 65HC-H13-MX-457x457-FW/7P H13 457x457x150 10,1 125 34065HC-H13-MX-305x610-FW/7P H13 305x610x150 9,0 125 300 65HC-H13-MX-305x305-FW/7P H13 305x305x150 4,5 125 150(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA CEILING FILTER with MDF Frame (MX;150mm - PH;125mm)Filter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Filter Model30456075901051201351500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] HEPA Ceiling Filter - Pleat Code:7 (PH125) H13 - 125mm H14 - 125mm37Specifications• Optimized velocity distribution • Polyurethane Gel gasket• Low pressure drop, less energy consumption • Various frame sizes with any dimensions• Guaranteed leak-free • Suitable for knife edge frame systems• Available in all grades • Excellent sealingFilter Class; H13 - H14 - U15 Media; High quality glass fibreSealing Compound; Two component polyurethane Separators; HotmeltFrame type; Anodized, extruded aluminium Flammability Class; K2/F2 for normal Temp. Faceguard; Aluminium sheet, powder coated Max. Final Pressure Drop; 600 PaGasket; GEL Max. Operating Temperature; 75°CFilter Type GasketHC :HEPA Ceiling Filter G: Gel GasketUC :ULPA Ceiling Filter Pleat HeightFilter Class (EN1822) N :42mm M :68mmH13 H14 U15 J :55mm L :92mmFaceguardFrame Type FB :Both Sides FD :Dirty SideAluminium FC :Clean Side FW :WithoutFrame DepthNJ :80mm MJ :104mmJ :91mm LJ :128mmwww.ulpatek.comFiltration area and pleat height designed with the optimum value are more important for performans of filters. The filters having high pleat height offer a good solution with lower operating costs and significantly reducing energy consumption.ADVANCED FILTRATION FOR A BETTER FUTUREHC-H14-AMJ-610x610-FB/MGWidht x Height (mm x mm)W x HAIR FILTER TECHNOLOGY (EN1822)GEL TYPE HEPA/ULPA CEILING FILTER with Aluminium Frame High-efficiency HEPA Ceiling Gel Type filters protect people, equipment and processes from airborne particulate contamination. Gel Type HEPA Ceiling filters are used in air ventilation and air conditioning plants requiring high or very high levels of air purity. They are designed for clean room ceilings and clean work tables to provide laminar flow.Applications: Industrial processes like microelectronics, medicine, pharma, the food industry, microbiology, chemistry, laboratories, hospital and hospital operating theatres, laminar flow boxes, fan filter units, nuclear energy and nuclear research38www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;42mm NGasket type Gel GFilter Dimensions WxH (mm) 610x610Faceguard Side Both Sides FBFrame Material Aluminium AFilter Depth 80mm NJ140HC-H14-ANJ-610x610-FB/NGFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H14UC-U15-ANJ-610x1220-FB/NG U15 610x1220x80 20,0 42 1200140UC-U15-ANJ-610x915-FB/NG U15 610x915x80 15,0 42 900 140UC-U15-ANJ-610x762-FB/NG U15 610x762x80 12,5 42 750140UC-U15-ANJ-610x610-FB/NG U15 610x610x80 10,0 42 600 140UC-U15-ANJ-457x457-FB/NG U15 457x457x80 5,6 42 340140UC-U15-ANJ-305x610-FB/NG U15 305x610x80 5,0 42 300 140UC-U15-ANJ-305x305-FB/NG U15 305x305x80 2,5 42 150125HC-H14-ANJ-610x1220-FB/NG H14 610x1220x80 18,8 42 1200 125HC-H14-ANJ-610x915-FB/NG H14 610x915x80 14,1 42 900125HC-H14-ANJ-610x762-FB/NG H14 610x762x80 11,7 42 750 125HC-H14-ANJ-610x610-FB/NG H14 610x610x80 9,4 42 600125HC-H14-ANJ-457x457-FB/NG H14 457x457x80 5,3 42 340 125HC-H14-ANJ-305x610-FB/NG H14 305x610x80 4,7 42 300100HC-H14-ANJ-305x305-FB/NG H14 305x305x80 2,4 42 150 125HC-H13-ANJ-610x1220-FB/NG H13 610x1220x80 18,0 42 1200100HC-H13-ANJ-610x915-FB/NG H13 610x915x80 13,5 42 900 100HC-H13-ANJ-610x762-FB/NG H13 610x762x80 11,2 42 750100HC-H13-ANJ-305x305-FB/NG H13 305x305x80 2,3 42 150100HC-H13-ANJ-610x610-FB/NG H13 610x610x80 9,0 42 600 100HC-H13-ANJ-457x457-FB/NG H13 457x457x80 5,1 42 340Other dimensions are available on request.(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)GEL TYPE HEPA/ULPA CEILING FILTER with Aluminium Frame (ANJ;80mm - PH;42mm)Filter ModelFilter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop 100HC-H13-ANJ-305x610-FB/NG H13 305x610x80 4,5 42 30050751001251501752002252500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75Initial pressure drop [Pa] Nominal Air Velocity [m/s] Gel Type Ceiling Filter - Pleat Code:N (PH42) H13 - 42mm H14 - 42mm U15 - 42mm39* For other pleat heights check the curves acc. to pleat code. www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;55mm JGasket type Gel GFilter Dimensions WxH (mm) 610x610Faceguard Side Both Sides FBFrame Material Aluminium AFilter Depth 91mm J125HC-H14-AJ-610x610-FB/JGFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H14UC-U15-AJ-610x1220-FB/JG U15 610x1220x91 24,0 55 1200125UC-U15-AJ-610x915-FB/JG U15 610x915x91 18,0 55 900 125UC-U15-AJ-610x762-FB/JG U15 610x762x91 15,0 55 750125UC-U15-AJ-610x610-FB/JG U15 610x610x91 12,0 55 600 125UC-U15-AJ-457x457-FB/JG U15 457x457x91 6,7 55 340125UC-U15-AJ-305x610-FB/JG U15 305x610x91 6,0 55 300 125UC-U15-AJ-305x305-FB/JG U15 305x305x91 3,0 55 150115HC-H14-AJ-610x1220-FB/JG H14 610x1220x91 22,5 55 1200 115HC-H14-AJ-610x915-FB/JG H14 610x915x91 16,9 55 900115HC-H14-AJ-610x762-FB/JG H14 610x762x91 14,1 55 750 115HC-H14-AJ-610x610-FB/JG H14 610x610x91 11,3 55 600115HC-H14-AJ-457x457-FB/JG H14 457x457x91 6,3 55 340 115HC-H14-AJ-305x610-FB/JG H14 305x610x91 5,6 55 30090HC-H14-AJ-305x305-FB/JG H14 305x305x91 2,8 55 150 115HC-H13-AJ-610x1220-FB/JG H13 610x1220x91 21,4 55 120090HC-H13-AJ-610x915-FB/JG H13 610x915x91 16,1 55 900 90HC-H13-AJ-610x762-FB/JG H13 610x762x91 13,4 55 75090HC-H13-AJ-305x305-FB/JG H13 305x305x91 2,7 55 15090HC-H13-AJ-610x610-FB/JG H13 610x610x91 10,7 55 600 90HC-H13-AJ-457x457-FB/JG H13 457x457x91 6,0 55 340Other dimensions are available on request.(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)GEL TYPE HEPA/ULPA CEILING FILTER with Aluminium Frame (AJ;91mm - PH;55mm)Filter ModelFilter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop 90HC-H13-AJ-305x610-FB/JG H13 305x610x91 5,4 55 3005070901101301501701902102302500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] Gel Type Ceiling Filter - Pleat Code:J (PH55) H13 - 55mm H14 - 55mm40* For other pleat heights check the curves acc. to pleat code. www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;68mm MGasket type Gel GFilter Dimensions WxH (mm) 610x610Faceguard Side Both Sides FBFrame Material Aluminium AFilter Depth 104mm MJ115HC-H14-AMJ-610x610-FB/MGFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H14UC-U15-AMJ-610x1220-FB/MG U15 610x1220x104 28,0 68 1200115UC-U15-AMJ-610x915-FB/MG U15 610x915x104 21,0 68 900 115UC-U15-AMJ-610x762-FB/MG U15 610x762x104 17,5 68 750115UC-U15-AMJ-610x610-FB/MG U15 610x610x104 14,0 68 600 115UC-U15-AMJ-457x457-FB/MG U15 457x457x104 7,9 68 340115UC-U15-AMJ-305x610-FB/MG U15 305x610x104 7,0 68 300 115UC-U15-AMJ-305x305-FB/MG U15 305x305x104 3,5 68 150100HC-H14-AMJ-610x1220-FB/MG H14 610x1220x104 26,7 68 1200 100HC-H14-AMJ-610x915-FB/MG H14 610x915x104 19,7 68 900100HC-H14-AMJ-610x762-FB/MG H14 610x762x104 16,4 68 750 100HC-H14-AMJ-610x610-FB/MG H14 610x610x104 13,1 68 600100HC-H14-AMJ-457x457-FB/MG H14 457x457x104 7,4 68 340 100HC-H14-AMJ-305x610-FB/MG H14 305x610x104 6,6 68 30085HC-H14-AMJ-305x305-FB/MG H14 305x305x104 3,3 68 150 100HC-H13-AMJ-610x1220-FB/MG H13 610x1220x104 24,8 68 120085HC-H13-AMJ-610x915-FB/MG H13 610x915x104 18,6 68 900 85HC-H13-AMJ-610x762-FB/MG H13 610x762x104 15,5 68 75085HC-H13-AMJ-305x305-FB/MG H13 305x305x104 3,1 68 15085HC-H13-AMJ-610x610-FB/MG H13 610x610x104 12,4 68 600 85HC-H13-AMJ-457x457-FB/MG H13 457x457x104 7,0 68 340Other dimensions are available on request.(EN1822) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)GEL TYPE HEPA/ULPA CEILING FILTER with Aluminium Frame (AMJ;104mm - PH;68mm)Filter ModelFilter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop 85HC-H13-AMJ-305x610-FB/MG H13 305x610x104 6,2 68 3004060801001201401601802002200,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] Gel Type Ceiling Filter - Pleat Code:M (PH68) H13 - 68mm H14 - 68mm41* For other pleat heights check the curves acc. to pleat code. www.ulpatek.comPleat Code PH;92mm LGasket type Gel GFilter Dimensions WxH (mm) 610x610Faceguard Side Both Sides FBFrame Material Aluminium AFilter Depth 128mm LJ100HC-H14-ALJ-610x610-FB/LGFilter Model Hepa Ceiling HCFilter Class H14 (EN1822) H14UC-U15-ALJ-610x1220-FB/LG U15 610x1220x128 40,0 92 1200100UC-U15-ALJ-610x915-FB/LG U15 610x915x128 30,0 92 900 100UC-U15-ALJ-610x762-FB/LG U15 610x762x128 25,0 92 750100UC-U15-ALJ-610x610-FB/LG U15 610x610x128 20,0 92 600 100UC-U15-ALJ-457x457-FB/LG U15 457x457x128 11,2 92 340100UC-U15-ALJ-305x610-FB/LG U15 305x610x128 10,0 92 300 100UC-U15-ALJ-305x305-FB/LG U15 305x305x128 5,0 92 15080HC-H14-ALJ-610x1220-FB/LG H14 610x1220x128 37,6 92 1200 80HC-H14-ALJ-610x915-FB/LG H14 610x915x128 28,2 92 90080HC-H14-ALJ-610x762-FB/LG H14 610x762x128 23,5 92 750 80HC-H14-ALJ-610x610-FB/LG H14 610x610x128 18,8 92 60080HC-H14-ALJ-457x457-FB/LG H14 457x457x128 10,6 92 340 80HC-H14-ALJ-305x610-FB/LG H14 305x610x128 9,4 92 30065HC-H14-ALJ-305x305-FB/LG H14 305x305x128 4,7 92 150 80HC-H13-ALJ-610x1220-FB/LG H13 610x1220x128 36,0 92 120065HC-H13-ALJ-610x915-FB/LG H13 610x915x128 27,0 92 900 65HC-H13-ALJ-610x762-FB/LG H13 610x762x128 22,5 92 750H13 610x610x128 18,0 92 600 65HC-H13-ALJ-457x457-FB/LG H13 457x457x128 10,1 92 340AIR FILTER TECHNOLOGY (EN1822)GEL TYPE HEPA/ULPA CEILING FILTER with Aluminium Frame (ALJ;128mm - PH;92mm)Filter ModelFilter Class Dimensions WxHxD Filtration AreaPleat Height Nominal AirflowInitial Pressure Drop Other dimensions are available on request.ADVANCED FILTRATION FOR A BETTER FUTURE(EN1822) (mm) (m²) (mm) (m³/h) (Pa)65HC-H13-ALJ-305x610-FB/LG H13 305x610x128 9,0 92 300 65HC-H13-ALJ-305x305-FB/LG H13 305x305x128 4,5 92 15065HC-H13-ALJ-610x610-FB/LG4060801001201401601800,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] Gel Type Ceiling Filter - Pleat Code:L (PH92) H13 - 92mm H14 - 92mm42Specifications• Optimized velocity distribution • Disposable filter modules• Low pressure drop, less energy consumption • With individual test certificated• Guaranteed leak-free • Factory sealed unit filter• Adjustable airflow by means of a damper • Interchangeable with existing filters• Ready to install • Assembled without screws or fasteners• Aluminium cover and spigot • Emery (DOP) and ?P nozzles includedMedia; High quality glass fibreSealing Compound; Two component polyurethane Separators; HotmeltFrame type; Anodized, extruded aluminium Flammability Class; K2/F2 for normal Temp. Max. Final Pressure Drop; 600 PaSpigot Diameter; 160-200-250-315mm Max. Operating Temperature; 75°CNote: Add 15Pa to initial resistance for hood contructionFilter Type Spigot Diameter (Ø)HTH :HEPA Terminal Hood Filter S :160mm M :250mm Z :SpecialUTH :ULPA Terminal Hood Filter N :200mm L :315mmFilter Class (EN1822) 0 :Without E :EPDM P :Pu FoamH14 U151 : 50mm 6 :100mmFrame Type Adjsutable MechanismA :Aluminium FC1 :Without Adjustable MechanismFC2 :With Adjustable MechanismFrame DepthL :125mm X :175mmwww.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREHTH-H14-AL-610x610-FC1/10MGasketH13 Pleat HeightWidht x Height (mm x mm)W x HFiltration area and pleat height designed with the optimum value are more important for performans of filters. The filters having high pleat height offer a good solution with lower operating costs and significantly reducing energy consumption.Volume can be adjusted by perforated distribution plate from roomside with a screwdriver through an access port located in the center of the unit. For an optional application where the volume control is not necessary the fixed distribution plate is also available (divider is not included).Filter Class; H13 - H14 - U15Faceguard; Aluminium sheet, powder coatedAIR FILTER TECHNOLOGY (EN1822)HEPA TERMINAL HOOD FILTER with Aluminium FrameHigh-efficiency HEPA Terminal Hood filters protect people, equipment and processes from airborne particulate contamination. HEPA Terminal Hood filters are used in air ventilation and air conditioning plants requiring high or very high levels of air purity. They are designed for clean room ceilings and clean work tables to provide laminar flow.Applications: Industrial processes like microelectronics, medicine, pharma, the food industry, microbiology, chemistry, laboratories, hospital and hospital operating theatres, laminar flow boxes, nuclear energy and nuclear research.DOP Test nozzleDifferential pressure nozzlePerforated distribution plateSiliconFace guardFilter paperFlexible ductSuspended ceilingDividerAdjustable volumecontrol mechanism43www.ulpatek.comSpigot Diameter PH;250mm MADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;50mm 1Gasket type Without 0Filter Dimensions WxH (mm) 610x610Adj. Mechanism Without FC1Frame Material Aluminium AFilter Depth 125mm LHTH-H14-AL-610x610-FC1/10MFilter Model HEPA Hood HTHFilter Class H14 (EN1822) H14900 135315 22,0 50 1200 135U15 610x915x125 315 16,5 50600 135U15 610x762x125 250 13,7 50 750 135U15 610x610x125 250 11,0 50300 135U15 457x457x125 200 6,2 50 340 135U15 305x610x125 200 5,5 50HTH-H14-AL-610x915-FC1/10LHTH-H14-AL-610x762-FC1/10M1200 115U15 305x305x125 160 2,8 50 150 135H14 610x1220x125 315 22,0 50750 115H14 610x915x125 315 16,5 50 900 115H14 610x762x125 250 13,7 50HTH-H14-AL-457x457-FC1/10NHTH-H14-AL-305x610-FC1/10NH14 610x610x125 250 11,0 50 600 115H14 457x457x125 200 6,2 50HTH-H14-AL-610x610-FC1/10MH14 305x610x125 200 5,5 50 300 115340 115HTH-H13-AL-610x915-FC1/10LHTH-H13-AL-610x762-FC1/10M1200 90H14 305x305x125 160 2,8 50 150H13 610x1220x125 315 22,0 50115HTH-H14-AL-305x305-FC1/10SHTH-H13-AL-610x1220-FC1/10L750 90H13 610x915x125 315 16,5 50 900 90H13 610x762x125 250 13,7 50HTH-H13-AL-305x610-FC1/10NHTH-H13-AL-305x305-FC1/10S340 90H13 610x610x125 250 11,0 50 600 90H13 457x457x125 200 6,2 50HTH-H13-AL-610x610-FC1/10MHTH-H13-AL-457x457-FC1/10N150 90H13 305x610x125 200 5,5 50 300 90H13 305x305x125 160 2,8 50Initial Pressure Drop (EN1822) (mm) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA/ULPA TERMINAL HOOD FILTER with Aluminium Frame (AL;125mm - PH;50mm)Filter ModelFilter Class Dimensions WxHxD Spigot Diameter Filtration AreaPleat Height Nominal AirflowOther dimensions are available on request.UTH-U15-AL-610x1220-FC1/10LUTH-U15-AL-610x915-FC1/10LUTH-U15-AL-610x762-FC1/10MUTH-U15-AL-610x610-FC1/10MUTH-U15-AL-457x457-FC1/10NUTH-U15-AL-305x610-FC1/10NUTH-U15-AL-305x305-FC1/10SHTH-H14-AL-610x1220-FC1/10LU15 610x1220x12550751001251501752002252500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75Initial pressure drop [Pa] Nominal Air Velocity [m/s] Terminal Hood Filter - Pleat Code:1 (PH50) H13 - 50mm H14 - 50mm U15 - 50mm44* For other pleat heights check the curves acc. to pleat code. www.ulpatek.comMAdj. Mechanism Available1Pleat Code PH;50mm0FC2Filter Class H14 (EN1822)AFrame Material AluminiumXGasket type WithoutFilter Model HEPA HoodH14900 135Filter Depth 175mm610x610Filter Dimensions WxH (mm)1351200610x915x175 315 16,5 50U15U15UTH-U15-AX-610x1220-FC2/10LUTH-U15-AX-610x915-FC2/10LU15U15UTH-U15-AX-610x762-FC2/10MUTH-U15-AX-610x610-FC2/10M610x1220x175 315 22,0 50600 135610x762x175 250 13,7 50 750 135610x610x175 250 11,0 50UTH-U15-AX-305x305-FC2/10SHTH-H14-AX-610x1220-FC2/10L300 135457x457x175 200 6,2 50 340 135305x610x175 200 5,5 50U15UTH-U15-AX-457x457-FC2/10NUTH-U15-AX-305x610-FC2/10N1200 115305x305x175 160 2,8 50 150 135610x1220x175 315 22,0 50HTH-H14-AX-610x610-FC2/10M750 115610x915x175 315 16,5 50 900 115610x762x175 250 13,7 50HTH-H14-AX-610x762-FC2/10MHTH-H14-AX-610x915-FC2/10L610x610x175 250 11,0 50 600 115457x457x175 200 6,2 50305x610x175 200 5,5 50 300 115340 115HTH-H14-AX-305x610-FC2/10NHTH-H14-AX-457x457-FC2/10NHTH-H13-AX-610x762-FC2/10MHTH-H13-AX-610x915-FC2/10L1200 90305x305x175 160 2,8 50 150610x1220x175 315 22,0 50115HTH-H13-AX-610x1220-FC2/10LHTH-H14-AX-305x305-FC2/10S750 90610x915x175 315 16,5 50 900 90610x762x175 250 13,7 50HTH-H13-AX-305x305-FC2/10SHTH-H13-AX-305x610-FC2/10N340 90610x610x175 250 11,0 50 600 90457x457x175 200 6,2 50HTH-H13-AX-457x457-FC2/10NHTH-H13-AX-610x610-FC2/10M150 90305x610x175 200 5,5 50 300 90305x305x175 160 2,8 50Initial Pressure Drop (mm) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA TERMINAL HOOD FILTER with Aluminium Frame (AX;175mm - PH;50mm)Filter ModelDimensions WxHxD Spigot Diameter Filtration AreaPleat Height Nominal AirflowOther dimensions are available on request.HTHADVANCED FILTRATION FOR A BETTER FUTUREHTH-H14-AX-610x610-FC2/10MSpigot Diameter PH;250mmFilter Class (EN1822)H13H13H13H13H13H13H13H14H14H14H14H14H14H14U15U1550751001251501752002252500,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75Initial pressure drop [Pa] Nominal Air Velocity [m/s] Terminal Hood Filter - Pleat Code:1 (PH50) H13 - 50mm H14 - 50mm U15 - 50mm45* For other pleat heights check the curves acc. to pleat code. www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREPleat Code PH;100mm 6Gasket type Without 0Spigot Diameter PH;250mm MFilter Depth 175mm XFilter Dimensions WxH (mm) 610x610Adj. Mechanism Without FC1HTH-H14-AX-610x610-FC1/60MFilter Model HEPA Hood HTHFilter Class H14 (EN1822) H14Frame Material Aluminium AU15 610x1220x175 315 40,0 100 1200 100U15 610x915x175 315 30,0 100 900 100600 100U15 610x762x175 250 25,0 100 750 100U15 610x610x175 250 20,0 100300 100U15 457x457x175 200 11,2 100 340 100U15 305x610x175 200 10,0 1001200 80U15 305x305x175 160 5,0 100 150 100H14 610x1220x175 315 37,6 100750 80H14 610x915x175 315 28,2 100 900 80H14 610x762x175 250 23,5 100200 9,4 100 300 80340 80H14 610x610x175 250 18,8 100 600 80H14 457x457x175 200 10,6 1001200 65H14 305x305x175 160 4,7 100 150H13 610x1220x175 315 36,0 10080750 65H13 610x915x175 315 27,0 100 900 65H13 610x762x175 250 22,5 100340 65H13 610x610x175 250 18,0 100 600 65H13 457x457x175 200 10,1 100150 65H13 305x610x175 200 9,0 100 300 65H13 305x305x175 160 4,5 100Initial Pressure Drop (EN1822) (mm) (mm) (m²) (mm) (m³/h) (Pa)AIR FILTER TECHNOLOGY (EN1822)HEPA TERMINAL HOOD FILTER with Aluminium Frame (AX;175mm - PH;100mm)Filter ModelFilter Class Dimensions WxHxD Spigot Diameter Filtration AreaPleat Height Nominal AirflowOther dimensions are available on request.HTH-H13-AX-305x305-FC1/60SHTH-H13-AX-305x610-FC1/60NHTH-H13-AX-457x457-FC1/60NHTH-H13-AX-610x610-FC1/60MHTH-H13-AX-610x762-FC1/60MHTH-H13-AX-610x915-FC1/60LHTH-H13-AX-610x1220-FC1/60LHTH-H14-AX-305x305-FC1/60SHTH-H14-AX-305x610-FC1/60NHTH-H14-AX-457x457-FC1/60NHTH-H14-AX-610x610-FC1/60MHTH-H14-AX-610x762-FC1/60MHTH-H14-AX-610x915-FC1/60LHTH-H14-AX-610x1220-FC1/60LUTH-U15-AX-305x305-FC1/60SUTH-U15-AX-305x610-FC1/60NUTH-U15-AX-457x457-FC1/60NUTH-U15-AX-610x610-FC1/60MUTH-U15-AX-610x762-FC1/60MUTH-U15-AX-610x915-FC1/60LUTH-U15-AX-610x1220-FC1/60LH14 305x610x1754060801001201401601800,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9Initial pressure drop [Pa] Nominal Air Velocity [m/s] Terminal Hood Filter - Pleat Code:6 (PH100) H13 - 100mm H14 - 100mm46Specifications• Large filter surface • Self-supporting and rigid• Less maintenance and energy consumption • Long service life• Header depth is 25mm • Easy installation• Fully incinerable without pollutant emission • Low pressure drop• Airflow and installation in any direction possibleFinal Pressure Drop; 450 PaMax. Operating Temperature; 75° CFrame type; %100 recycled plastic frame (PP) Application; Prefilter or final for HVACFaceguard; Without (available on request) Seperator; HotmeltGasket; Without (available on request) Sealing Compound; Two component polyurethaneFilter Type FacegaurdEV :Epa V-Compact Filter Two faceguard on the edge sidesHV :Hepa V-Compact FilterFilter Class (EN1822)E10 E12E11 H13www.ulpatek.comADVANCED FILTRATION FOR A BETTER FUTUREAIR FILTER TECHNOLOGY (EN1822)V-COMPACT FILTER EPA & HEPAFilter Class; E10 - E11 -E12 - H13Media; High quality glass fibreFilter ModelFilter Class Dimensions WxHxD Filtration AreaNominal Airflow Initial Pressure Drop (EN1822) (mm) (m ²) (m³/h) (Pa)200200EV-E10-592x592x292 E10 592x592x292 19 4000EV-E10-490x592x292 E10 490x592x292 15,3 3300200EV-E11-592x592x292 E11 592x592x292 19 3400 190EV-E10-287x592x292 E10 287x592x292 9,5 2000190EV-E11-287x592x292 E11 287x592x292 9,5 1700 190EV-E11-490x592x292 E11 490x592x292 15,3 2800270EV-E12-490x592x292 E12 490x592x292 15,3 2470 270EV-E12-592x592x292 E12 592x592x292 19 3000270HV-H13-592x592x292-FC2 H13 592x592x292 19 2500 250EV-E12-287x592x292 E12 287x592x292 9,5 1500HV-H13-287x592x292-FC2Widht x Height x Depth (mm x mm)W x H x D250HV-H13-287x592x292-FC2 H13 287x592x292 9,5 1250 250HV-H13-490x592x292-FC2 H13 490x592x292 15,3 200047Specifications• Single Pleat • For high air flow applications• Low pressure drop, less energy consumption • High quality glass fibre media• Guaranteed leak-free • Available in all grades• Available in all grad
Most popular related searches
