The 6001-02 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm system. The fully networkable 6001-02 is compatible with Numens addressable devices and can also be connected to non-addressable devices when used with addressable input modules. Default configuration programming facilitates out-of-box installation and rapid commissioning. A powerful and versatile cause-and-effect PC-based programming tool enables rapid customization with software for sites that require special operating features. The 6001-02 comes standard with features that allows flexibility and expandability. The 6001-02 control panel provides fire detection and alarm system designers with a premium product for life safety and property protection applications.
Most popular related searches

·          2 loop detection circuits

·          Networkable, up to 4 control panels

·          Supports up to 125 addressable devices per loop

·          Automatic device detection on start-up

·          Automatic device type-code verification

·          2 independently programmable non-addressable sounder output circuits

·          2 programmable relay outputs

·          Fault relay output

·          Remote disable and evacuation inputs

·          Backlit LCD display providing 4 rows of 40 characters

·          16 zone fire alarm LED indicators

·          3000 event history log

·          Attractive designer enclosure available in white

·          Recessed mounting

·          Easy installation

 

6001-02

Operating voltage

AC (85 ~ 260) V / 50/60 Hz

Mains supply current limit

1.5 A @ AC 230 V

Mains supply fuse

4 A / AC 250 V slow blow (20 mm)

Mains supply fault threshold voltage

≤ AC 60 V

Power supply

2.2 A @ DC 28 V

Standby battery capacity (2 × DC 12 V)

7.2 Ah

Maximum battery current draw

1.5 A @ maximum operating temperature

Battery fuse

6 A resettable (electronic fuse)

Battery fault threshold voltage

< DC 20 V

Quiescent current

110 mA @ 28.5 V

Addressable loops

2

Number of connected devices per loop

125

Loop current (max)

400 mA

Loop monitoring

Open- and short-circuit

Configurableaudio/visual alarm groups (max)

512

Non-addressable audio/visual alarm device driver

800 mA

Non-addressable audio/visual alarm end-of-line resistor

10 k?

Alarm zone monitoring

Open- and short-circuit

Alarm zone voltage (max)

DC 27.5 V

Alarm zone fuse

1.1 A resettable (electronic fuse)

Number of programmable output relays

2

Ancillary fire C/O relay

2 x (1.0 A @ DC 30 V / 1 A @ AC 240 V)

Ancillary fault N/C relay

1.0 A @ DC 30 V / 1 A @ AC 240 V

Auxiliary supply

DC 28 V @ 300 mA

Evacuation start / stop input

Non-latching, voltage-free

Remote reset input

Non-latching, voltage-free

Number of networked panels

4

Terminal wiring

(0.4 ~ 2.5) mm2

Operating temperature

(-5 ~ +40) °C

Operating humidity

(0 ~ 95) % RH, non-condensing

Storage temperature

(-25 ~ +80) °C

Storage humidity

(0 ~ 98) % RH, non-condensing

Dimensions (h × w × d)

(420 × 337 × 99) mm

Weight (excluding batteries)

4.0 kg

aRequires 6001-06 loop expansion card.

 

EN 54-2 a

EN 54-4 b

6001-01

 

6001-02

 

6001-05

 

 

aEN 54-2 Control and indicating equipment

b EN 54-4 Power supply equipment