- Home
- Equipment
Refine by
M&C Xprt Equipment & Supplies
27 equipment items found
Distributed by:Wall Grain Handling Systems based inWinnipeg, MANITOBA (CANADA)
The Legacy Series high capacity grain dryers may be used for dry and cool or all-heat operations. Each chamber of a Legacy Series contains a double wheel, double inlet, quiet centrifugal fan and Venturi Burner with modulated flame set between the fan wheels for a complete mixing of air and heat.Additionally, the quality construction and factory assembly of the M-C Legacy Series means quick field ...
Distributed by:Wall Grain Handling Systems based inWinnipeg, MANITOBA (CANADA)
The Infinity Series with 8 Low Profile Models, capacities from 325 BPH to 900 BPH, may be used in dry and cool or all heat drying systems to assure the output of the highest quality dried grain. With its 14′ 6″ overall height, the Infinity Series fits easily into those installations with height restrictions.Years of research, development and testing have led to the principle of ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Temperature controller 701 for PT100 sensor in a rail-mount housing, control range: 0 to 200 °C, contact rating: 10 A/250 V, power: 115 V/60 Hz. Electronical two-step controller for heated sample ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Electric gas cooler type ECP1000-G with Peltier element, electronically controlled to +5 °C, high/low temperature alarm with 2 changeover contacts, jet-stream heat exchanger made of Duran glass for 1 x 150 Nl/h, connections: sample gas: GL18-6 mm, condensate: GL 25-12 mm, power: 230 V/50 Hz or 115 V/60 Hz to switch over. One stream, max. flow 150 Nl/hr, different materials of heat exchangers, ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Gas sample probe type SP2000 with external ceramic filter type S-2K150, filter porosity: 2 µm, filter element seal and cover seal out of Viton, mounting flange: DN 65 PN 6B with G 3/4" f connection, material: SS 316Ti, Viton, ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Gas sample probe type SP2000-H with external ceramic filter type S-2K150, filter porosity: 2 µm, with electrically heated external filter 0 to 180 °C, adjustable by an integrated thermostat, high-temperature limiter with reset key responding at +30 °C Tset and low-temperature alarm with potential-free status-alarm contact at -30 °C below Tset, incl. weather protection shield ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Sample tube for PSP4000 type PSP4000/SS, incl. male G 3/8" connector and sealing, length: 1 m, 10 mm o.d., material: SS 316Ti, max. 600 ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Sample tube for PSP4000 type PSP4000/SS, incl. male G 3/8" connector and sealing, length: 1 m, 12 mm o.d., material: SS 316Ti, max. 600 ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Analytical bellows sample pump MP-F05, material: PTFE, capacity: 320 Nl/h with counter-pressure of -/+ 50 mbar on the vacuum and pressure side, connections: G 1/4" f, 230 V/230 V/50/60 Hz, IP54. Capacity: 5 Nl/min (320 Nl/h) with a counter-pressure of -/+ 50 mbar on the vaccuum and pressure side , power: 115 V/60 Hz or 230 V/50 ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Analytical bellows sample pump MP-F05, material: PTFE, capacity: 320 Nl/h with counter-pressure of -/+ 50 mbar on the vacuum and pressure side, connections: G 1/4" f, 115 V, 50/60 Hz, IP54. Capacity: 5 Nl/min (320 Nl/h) with a counter-pressure of -/+ 50 mbar on the vaccuum and pressure side , power: 115 V/60 Hz or 230 V/50 ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
The electrically heated, plug-in M&C sample lines series 3-N/M/H EX are used in gas analysis systems to avoid a distortion of measuring values and they also serve as anti-freeze protection during the transport of sample gas from the sample point to the gas conditioning system or directly to the heated analyzer (above dew ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
The electrically heated, plug-in M&C sample lines series 3-N/M/H EX are used in gas analysis systems to avoid a distortion of measuring values and they also serve as anti-freeze protection during the transport of sample gas from the sample point to the gas conditioning system or directly to the heated analyzer (above dew ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Gas sample dilution probe type SP2000-H/DIL with external ceramic filter type S-2K150, filter porosity: 2 µm, electrically heated external filter 0 to 180 °C adjustable by an intgrated thermostat, overtemperature limiter with reset key responding at +30 °C above Tset and undertemperature alarm with potential-free status-alarm contact at -30 °C below Tset, incl. weather ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Gas sample dilution probe type SP2000-H/DIL with external ceramic filter type S-2K150, filter porosity: 2 µm, electrically heated external filter 0 to 180 °C adjustable by an integrated thermostat, overtemperature limiter with reset key responding at +30 °C above Tset and undertemperture alarm with potential-free status-alarm contact at -30 °C below Tset, incl. weather ...
Distributed by:Wall Grain Handling Systems based inWinnipeg, MANITOBA (CANADA)
Next Generation Tower Series 8 Vacuum Cool, Energy Saving Models Vacuum cooling is key to the popularity and success of M-C Tower Dryers.Reclaiming heated air from cooling the grain results in less fuel usage and significant dollar savings. After blending the ambient air drawn from outside, the pre-heated air is returned to the blowers, lowering energy consumption and producing maximum ...
Distributed by:Wall Grain Handling Systems based inWinnipeg, MANITOBA (CANADA)
Commercial Tower Series Grain Dryer 4 Vacuum Cool, Energy Saving Models.Vacuum cooling is key to the popularity and success of M-C Tower Dryers. Reclaiming heated air from cooling the grain results in less fuel usage and significant dollar savings. After blending the ambient air drawn from outside, the pre-heated air is returned to the blowers, lowering energy consumption and producing maximum ...
Distributed by:Wall Grain Handling Systems based inWinnipeg, MANITOBA (CANADA)
Vacuum Cooling reclaims heated air from cooling the grain and results in less fuel usage and significant dollar savings. After blending with ambient air drawn from outside, the pre-heated air is returned to the blower, lowering energy consumption and producing maximum ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Gas sample probe type SP2000 with external ceramic filter type S-2K150, filter porosity: 2 µm, filter element seal and cover seal out of Viton, mounting flange: DN65PN6B with G 3/4" i connection, material: SS 316Ti, Viton, ceramics With ceramic filter element outside, optional: other filter materials, various possibilities of back purging and calibration gas feeding, second sample gas ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Gas sample probe type SP2000-H with external ceramic filter type S-2K150, filter porosity: 2 µm with electrically heated external filter 0 to 180 °C, adjustable by an integrated thermostat, overtemperature limiter with reset key responding at +30 °C Tset and undertemperature alarm with potential-free status-alarm contact at -30°C below Tset, incl. weather protection shield with ...
Manufactured by:M&C TechGroup based inRatingen, GERMANY
Temperature controller type TRD-H1 for PT100-sensor in a wall-mount enclosure, programmable control range: 0-390 °C, contact rating: 250 V/10 A, power: 90-250 V/50-60 Hz, panel jack, 7-pole (10 A), connection cable with Schuko plug. Electronical two-step controller for heated sample ...