Compact pressure sensor with the Contite measuring cell for hydrostatic level measurement. The compact Deltapilot FMB50 transmitter with the condensate resistant Contite measuring cell is typically used in the process and hygienic applications. It is made for level measurement in liquid and paste-like media in open or closed containers and unaffected by possible foam formation. For use in SIL2 safety systems.

Most popular related searches
  • Hermetically sealed Contite measuring cell with condensate-resistance, high reference accuracy: ±0.2%, optionally ±0.1% and minimum temperature effects

  • Modular concept for easy replacement of display or electronics

  • Seamless and independent system integration (HART/PA/FF)

  • Easy menu-guided commissioning via local display, 4 to 20mA with HART, PROFIBUS PA, FOUNDATION Fieldbus

  • International usage thanks to a wide range of approvals

For level and/or pressure measurement.

  • Process connections: Thread, flanges and flush-mounted hygienic connections

  • Process temperature: –10 to +100°C (14 to 212°F) (+135°C (275°F) for 30 minutes maximum)

  • Measuring range: 0.1 to 10bar (1.5 to 150psi)

  • Accuracy: ±0.2%, ±0.1% (option)

  • International explosion protection certificates, overfill prevention WHG, SIL, hygienic certificates

  • Measuring principle

    Hydrostatic

  • Characteristic

    Pressure transmitter for hydrostatic level measurement with flush mounted metallic CONTITE measuring cell:
    - hermetically welded
    - absolute condensation tight
    - climate-resitant
    - long-term stable
    - Lowest temperature influences

    Compact version

  • Supply voltage

    4...20 mA HART

    10,5...45 VDC (Non Ex):

    Ex ia: 10,5...30 VDC

    PROFIBUS PA:

    9...32 VDC (Non Ex)

    FOUNDATION Fieldbus:

    9...32 VDC (Non Ex)

  • Reference Accuracy

    Standard 0,2%
    Optional 0,1%

  • Long term stability

    0,05% of URL/year

  • Process temperature

    -10°C...100°C
    (14°F...212°F)

  • Ambient temperature

    -40°C...85°C
    (-40°F...185°F)

  • Measuring cell

    100 mbar...10 bar
    (1.5 psi...150 psi)

  • Smallest calibratable span

    10 mbar (1.45 psi)

  • Vacuum resistance

    0 mbar abs.

  • Max. Turn down

    100:1

  • Max. overpressure limit

    40 bar (600 psi)

  • Process connection

    Thread:

    G1 1/2, MNPT1 1/2

    Flange:

    DN40...DN100,

    ASME 1 1/2"...4",

    JIS 10K

  • Process connection hygienic

    Tri-Clamp

    DIN11851

    DIN11864-1

    NEUMO

    Varivent N

    SMS

    DRD

  • Material process membrane

    316L, AlloyC

    Gold-Rhodium

  • Material gasket

    None, measuring cell welded

  • Fill fluid

    Inert oil,

    Synthetic oil

  • Material housing

    316L, Die-cast aluminum

  • Communication

    4...20 mA HART

    PROFIBUS PA

    FOUNDATION Fieldbus

  • Certificates / Approvals

    ATEX, FM, CSA, CSA C/US, IEC Ex, INMETRO, NEPSI

  • Safety approvals

    Overfill prevention WHG

    SIL

  • Design approvals

    EN10204-3.1

    NACE MR0103

  • Hygienic approvals

    3A, EHEDG

    CoC ASME-BPE

  • Marine approvals

    GL/ ABS/ LR/ BV/ DNV

  • Drinking water approvals

    KTW/ NSF/ ACS

  • Specialities

    Modularity to differential pressure and process pressure devices (replacable display, universal electronics)

    Diagnostic functions

    Hermetically sealed Contite measuring cell (condensate-resistant and climatic-proofed)