Envea - Model MIR IS -In-Situ Close-Coupled Multi-Gas Analyzer
FromENVEA
A complete “all in one compact” system, for multi-gas measurements, based on the field-proven MIR 9000 analyzer and on-board SEC sampling system. Fast & simultaneous measurement of up to 10 gases among: HCl, NO, NO2 (NOx), SO2, CO, CO2, HC, CH4 (TOC), HF, N2O, O2, at the sampling location, Integrated sample drying & system conditioning; no sample line necessary.
Most popular related searches
multi-gas
stainless steel enclosure
multi-gas monitoring
multi-gas analyzer
EN 15267
combustion monitoring
EPA 40 CFR
EN 14181
EPA compliance
infrared analyzer
- Robust analyzer with a stainless steel enclosure
- Designed for measuring wet & corrosive samples
- Ease of installation (single stack entry, on-stack or close-coupled) for reduced costs
- Flow, Temperature & Pressure parameters (optional)
- Remote control and display functions
- Graphic LCD screen with real time synoptic
- Intrinsic security with on-board residual H2O measurement
- On-board paramagnetic cell for long term O2 measurement
- Fast response time, with automatic cross interference correction
- Robust and reliable short extractive analyzer with built-in permeation sample drying system for the measurement of wet and corrosive sample
- Complete CEMS in one cabinet – combines infrared analyzer, sample conditioning
system and probe into one device - Highly accurate; excellent calibration stability with automatic optical check
- Heated probe in different materials and lengths to suit the application
- External signal input for up to 5 additional measurements (flow rate, pressure, gas temperature…) or any other analog input
- Industrial Boilers and Furnaces, Chemical and Petrochemical Plants
- Incineration, Co-generation, Gas Turbines, Power Plants
- Process Control, Pre/post Scrubber Measurements
- Coal / Oil / Gas Fired Combustion Monitoring
- CHP Combustion Monitoring
- QAL1 to EN 15267-3 certified: YES
- US EPA compliance: YES
- Sampling technology: In-Situ
- Sample transfer: N/A
- back flush function: YES
- span injection: YES at sample point
- Built-In O2 option: YES
- Serial link communication: RS232 / RS422
- Other Communication: Ethernet
- Analogue OUTPUTS: YES (x 8)
- Analogue INPUTS: YES (x 4)
- Dimensions (mm): SS Tight box: 200 x 600 x 600 (D x W x H)
COMPLIANCE WITH WID AND LCPD APPLICATIONS
- QAL 1 according to MCERTs (CSA MC 040030/10) according to EN 15267
- QAL3 compliance as defined by EN 14181
- U.S. EPA approved as compliant with 40 CFR 60 ET 75