Eutech Instruments Pte Ltd.
- Home
- Companies
- Eutech Instruments Pte Ltd.
- Products
- Eutech - Model PC 700 - Multi-Parameter ...
Eutech - Model PC 700 -Multi-Parameter Standard Bench Meter
The multi-parameter Eutech PC 700 measures pH, ORP, conductivity and temperature with a single meter. User-friendly with advanced features and a large custom-size display – perfect for research work on a budget!
Most popular related searches
multiparameter meter
cooling tower water quality
pH/ORP/conductivity
pH/redox
cooling tower water
food industry waste
water quality testing
water quality
process water industry
waste processing industry
- Large Display - Large screen in a compact footprint
- Multi-Parameter - Meter accepts pH and Redox electrodes, in addition to Conductivity/TDS – it’s like having four meters in one!
- Advanced Calibration - Up to 5-point push button calibration
- Flexible Cell Constant - Selectable cell constant
- Auto-Ranging - Auto-ranging across 5 Conductivity ranges
- Interchangeable Probes - Easy interchangeability of probes
- Data Storage - Non-volatile memory holds up to 100 data points
- Built-in Holder - Integral electrode holder
- Water quality testing
- Checking metal finishes
- Solutions
- Cooling tower water
- Quality assurance
- Printing fountain solutions
- Boiler water
- Brines
- Drilling mud
- Ecological studies
- Rinse tanks
- Ponds
- Pollution control
- Recirculating systems
- Food-processing
- Waste water
- Industrial process systems
- General use in laboratories
- Titration
Product Specification: Description
- pH:
- Range: -2.00 to 16.00 pH
- Resolution: 0.01 pH
- Accuracy: ±0.01 pH
- Cal. Points: Up to 5
- Buffer Sets: USA (1.68, 4.01, 7.00, 10.01, 12.45),
- NIST (1.68, 4.01, 6.86, 9.18, 12.45)
- ORP:
- Range: ±2000 mV
- Rel. mV Range: ±2000 mV
- Resolution: 0.1 mV (±199.9 mV) / 1 mV (beyond)
- Accuracy: ±0.2 mV (±199.9 mV) / ±2 mV (beyond)
- Conductivity:
- Range: 0.0 µS to 200.0 mS
- Resolution: 0.01 / 0.1 / 1 µS ; 0.01 / 0.1 mS
- Accuracy: ±1 % full scale
- Cal. Points: Automatic (84 µS, 1413 µS, 12.88 mS, 111.8 mS); maximum 1 per range;
- manual (5 points); maximum 1 per range
- Cell Constant: 0.1, 1.0, 10.0 (selectable)
- TDS:
- Range: .. to 100.0 ppt @ 0.5 fact (200.0 ppt @ 1 factor)
- Resolution: 0.01 / 0.1 / 1 ppm ; 0.01 / 0.1 ppt
- Accuracy: ±1 % full scale
- Cal. Points: Manual (5 points); maximum 1 per range
- TDS Factor: 0.40 to 1.00 (adjustable)
- Temperature:
- Range (Meter): 0.0 to 100.0 ºC / 32.0 to 212.0 ºF
- Resolution: 0.1 ºC / 0.1 ºF
- Accuracy: ±0.5 ºC / ±0.9 ºF
- Coefficient (Per ºC): 0.00 to 10.00 %
- Normalization: 15.0 to 30.0 ºC (adjustable)
- Compensation:
- Type & Range: Automatic with supplied cell or manual
- 0.0 to 100 ºC / 32.0 to 212.0 ºF, 0 to 80 ºC / 32.0 to 176.0 ºF with supplied cell
- Power:
- Power Requirements: 9 V DC adapter, 1.3 A (100/240 VAC, SMPS)