- Model FL200 - On-line Fluorometer
Model FL200 -On-line Fluorometer
Mixed use: portable or fixed installations. Built-in sampling pump and battery. Measurement within 5 seconds. Low maintenance and operating costs. Compact size.
Most popular related searches
drinking water treatment plant
water treatment plant
drinking water treatment
water treatment
hydrocarbons in water
groundwater control
peristaltic sampling pump
drinking water plant
groundwater contamination
peristaltic pump
Based on UV or visible fluorescence, a wide range of applications can be covered by the FL200 depending on the optical head used:
- FL200-C: Chlorophyll A
- FL200-H: PAH (aromatic hydrocarbons) in water (BTEX, Phenol, oil, fuel)
- FL200-R: Rhodamine
- FL200-F: Fluorescein
Using a high sensitivity photomultiplier, the FL200 can measure very low concentrations in the ppb range.
Main applications
Chlorophyll A
- River, lake, reservoir surveys
- Drinking water treatment plants
- fish farms
PAH
- River surveys
- Ground water control cleansing
- Drinking water treatment plants
- Cooling water survey
Fluorescent tracers
- Ground water contaminant studies for chemical plants
- Flow calibration of water treatment plants
- Flow measurement in streams.
Very low operating costs
- The UV spectroscopy measuring principle requires no chemical reagent or calibration solutions resulting in very low operating and maintenance costs.
Automatic cleaning system
- A fully automated cleaning system prevents the measurement flow cell from becoming dirty, giving the analyser autonomy for several weeks without maintenance.
- The cleaning solution (5% sulphuric acid) should be renewed once a month.
Built-in peristaltic pump
- When the water is not pressurised (rivers, effluents, sewage), a peristaltic pump can be added to the analyser. It is synchronized with the measurements to increase the lifetime of the tubes.
Battery/mains power supply
- For field measurements or isolated sites, a 12V built-in battery can make the analyser autonomous for about 100 measurements.
- For plant applications, the battery provides total immunity against mains disturbances or power cuts, even over a long period.
Built-in datalogger
- The measurements are dated and stored in a static memory with a capacity of more than 10,000 measurements.
- They can be tranferred later via the RS232 port on a PC without specific software using
- Hyperterminalâ of Windowsâ . The data are compatible with standard worksheets, particularly Excelâ , to obtain graphs easily.
Graphic display
- Measurements can be displayed on the graphic screen showing all data obtained during one hour, one day, one week, one month or one year.
- During the measurement cycle, a moving synoptic shows the operation sequence.
Options
- Peristaltic sampling pump
- Measurement remote command
- Modem board
Specifications on-line fluorometer FL200
- Range: FL200-C: 0 - 300 µg/l Chl A
- FL200-H: 0 - 10 mg/l phenol equiv.
- FL200-R: 0 - 1000 ppb Rhodamine
- FL200-F: 0 - 1000 ppb Fluorescein
- Repeatability FL200-C: +/- 0.3 µg/l Chl. A typical
- Repeatability FL200-H: +/- 3 µg/l Phenol equiv. typical
- Repeatability FL200-R: +/- 0.03 ppb Rhodamine typical
- Repeatability FL200-F: +/- 0.03 ppb Fluorescein typical
- Initial calibration: +/- 2% typical
- Sample input/output: Stainless steel fitting for plastic tube external diameter 12 mm
- Pressure: Maximum 5 Bar
- Flow: 0 - 5 L/mn, typical 0.5 L/mn
- Sample temperature: > 0°C - 50°C
- Outputs: 4-20 mA insulated,12 bit resolution
- High and low threshold relays
- Communication: Port 1: RS232 for PC or modem or MODBUS
- Port 2: RS232 for on-line printer
- Power supply: 110-120 / 220-240V 50/60 Hz 30VA
- + built-in 12V battery
- Casing: Watertight IP559 - Ambient temperature > 0°C - 60°C
- Weight: 13 Kg /18 Kg without/with cleaning system
- Standards: CE Conformity - EN50081-2, EN50082-2, EN55011