NWspec
Nwspec - Model LC-8000 -Smart HPLC System
FromNWspec
The LC-8000 is a smart, modular HPLC system designed for high-performance gradient separations. Combining a precision binary pump, variable wavelength detector, and an intelligent system controller, this system ensures stability, durability, and simplicity in operation—ideal for routine and advanced applications.
Most popular related searches
HPLC system
HPLC system engineering
variable wavelength detector
UV-VIS detector
flow cell
well plate
chromatography column
HPLC
digital temperature controller
guard column
Infusion pump unit: Four-element low-pressure infusion pump
- Maximum pressure resistance: 6000 psi (40Mpa)
- Flow rate range: 0.001-10,000 mL/min (increment 0.001mL/min)
- Flow accuracy: ≤0.06% RSD(ASTM)
- Flow accuracy: ±0.2%
- Pressure pulsation: ≤1%
- Gradient accuracy: ±0.5%
- Gradient repeatability: ≤0.1%
- Online cleaning of plungers: Standard configuration, high/medium/low speed
- Channel volume: Four-channel degassing function, 480 μ L/channel
Detector: Ultraviolet-visible detector
- Wavelength range: 190-800 nm
- Light sources: deuterium lamp, tungsten lamp
- Spectral bandwidth: 8 nm
- Wavelength accuracy: ±1 nm
- Noise: ±0.35×10-5 AU (ASTM)
- Drift: 1×10-4 AU/Hr
- Wavelength accuracy: 0.2 nm
- Linear range: >2.5AU (ASTM)
- Maximum sampling rate: 100Hz
- Pressure resistance of the flow cell: 1200PSI
- Flow cell aperture: 10mm
- Minimum detectable concentration: 4×10-9 g/mL
Sampler: Automatic sampler
- Injection mode: Full-loop injection/Partial injection/micro-liter carrier injection
- Quantitative loop volume: Standard configuration is 100 μL
- Injection repeatability: Full-loop injection: RSD≤0.3%; Partial injection: RSD≤0.5%; micro-liter carryover injection: RSD≤1%
- Sample capacity: 2 standard 48-position sample bottle racks, 1.5mL injection bottles (standard configuration)
- (96-well plate and 384-well plate are optional)
- Cross-contamination: < 0.005%
- Linearity: 0.9999
- Maximum pressure resistance: 6000psi (customizable)
Column oven
- Temperature control range: Room temperature +5℃-70℃
- Temperature accuracy: ±1.0℃
- Temperature stability: ±0.1℃
- Column capacity: 1 250mm chromatographic column (1 10mm guard column can be added)
Chromatographic column
Standard configuration: C8,250×4.6mm,5um
Chromatography workstation
- Regulatory applicability: Complies with FDA 21 CFR Part11/GMP/GLP standards;
- Ease of use: The graphical monitoring interface enables you to keep track of the device status at any time, making it simple and easy to use.
- Data Processing: Powerful data processing capabilities, providing multiple integration functions and calculation methods;
- Rich functions: Automatic peak width, automatic threshold algorithm, adaptive data collection, and automatic algorithm adjustment to achieve the best integration effect;
- User Management: It features a powerful and comprehensive user management function, allowing for the setting of access permissions for convenient management. Different usage permissions can be set according to actual needs.