The TSP600N is TXAM’s top tier automation pump controller. Modes of operation include QPD, ProFlo, H2S, and dynamic temperature control, all utilizing stroke counting to maintain injection rates. The TSP600N utilizes Modbus RS 485/TCP for controlling and monitoring through a local network or TXAM’s proprietary CLOUD network. Additional features include a standard tank level sensor, temperature probe, emergency pump inhibit, analog input used for rate control (ProFlo/H2S).
Most popular related searches
tank level monitoring
temperature probe
level sensor
digital temperature controller
tank sensor
integrity monitoring
pump controller
H2S
temperature sensor
cloud monitor
- ProFlo
- H2S Mode
- Dynamic Temperature Mode
- Tank Level Sensor
- Cloud Integration (Monitoring & Control)
- Stroke Counting
Power
- 12v DC/120v AC input
- 12v DC/120v AC output
- BLDC with TXAM Driver Board
- 200mA
Control Options
- Proflo
- Pro H2S
- Dynamic Temperature
- QPD Mode
- Basic Timer
Input/Output
- 1x Digital Input
- 2x Analog Inputs
- 1x Standard Temperature Probe
- RS485; TCP