Shield Validation & Maintenance Services
Like all high quality equipment, shielding enclosures require regular maintenance and testing to ensure their continued performance. After construction, testing the newly built shielded enclosure is the most critical part of the build. Global EMC’s experienced test engineers offer RF, Magnetic field and acoustic testing across a broad range of frequencies to put your mind at ease, ensure the shield is operational and identify any areas of concern.
RF testing examines whether the electric field or plane wave can penetrate the shielded enclosure. Often even the smallest hole can compromise the shielding effectiveness and prevent the shield from performing optimally.
With decades of experience performing shielding effectiveness test, finding, and repairing leaks, Global EMC are happy to provide RF testing from 400 MHz to 40 GHz. We offer testing following EN 50147-1, MIL-STD-285, and other standards, but if you have different requirements, please do contact us and we will do our best to accommodate them.
Found at lower frequencies, magnetic fields are often more difficult to shield against than their RF counterparts. With larger wavelengths, the areas of ingress are more limited, however, some of the most common causes for shield failure are dust and dirt preventing a complete shield contact.
Global EMC are happy to provide RF testing from 9 kHz to 30 MHz. We offer testing following EN 50147-1, MIL-STD-285, and other standards, but if you have different requirements, please do contact us and we will do our best to accommodate them.
Being formed of pressure waves, acoustic sound can pose different problems to shielded enclosures than EM waves. Precision microscopes, research and other applications can all be affected if the noise level is too high. A better understanding of the acoustics of a room, and more importantly the acoustic absorption can be provided with an acoustic attenuation test.
Providing an insight into the level of attenuation of acoustic waves as they travel enter or exit the shielded enclosure, Global EMC’s acoustic testing service will inform you how well your enclosure is absorbing sound. Using an omnidirectional dodecahedron, we can test all audio frequencies and provide a detailed report of how well they are absorbed.