Thermometer Calibration Services
From -196 to 1000 °C or -320 to 1800 °F. ASTM, glass lab and digital thermometers, thermocouples, thermistors, PT100 sensors, RTDs, PRTs, bimetal and industrial thermometers.
- NIST Traceable
- ISO/IEC 17025 Accredited
Our lab is accredited by the A2LA to ISO/IEC 17025-2005 and ANSI/NCSL Z-540-1-1994. Your ISO 9000 (series) or other quality program in most cases recognize this accreditation and can accept our calibrations without the burden of conducting site audits or quality surveys.
Our A2LA Certificate & Scope of Accreditation
- Your instrument will be examined under magnification for any chips, scratches, impurities in the bore or other defects which may impair its function.
- Any separations of the liquid will be repaired without charge.
- If the etchings are faded, the scale will be repainted without charge.
- Your instrument will be compared to NIST traceable reference standards at the test points you specify, in accordance with appropriate ASTM and NIST test methods. A new NIST Traceable certificate of calibration will be issued, valid for the period of time that you specify. This certificate meets the requirements of ISO 17025, ANSI-NCSLI Z540.1, ISO 9000, and virtually all regulatory authorities.
- A durable calibration sticker will be affixed to your thermometer with the date of calibration, recalibration due date and other appropriate information .
- The instruments are our responsibility on return shipment to you. We pack them extremely well. If any are damaged in transit to you, you will receive a prompt, no charge PRIORITY replacement. No questions, no hassle.
- Your instrument(s) will be registered in our Customer Registration database. This will enable us to inform you in writing one month before the expiration of your calibration certificate that recalibration is due, and permit us to keep you abreast of any changes in industry regulations which may affect your calibration.
When your instrument is calibrated, it is compared to NIST certified primary master standards at the test points specified by the customer or ICL, in accordance to ASTM and NIST test methods.
A new NIST Traceable certificate of calibration will be issued, valid for the period of time that you specify. This certificate meets the requirements of ISO/IEC Guide 25, ISO/IEC 17025, the FDA, the EPA, and the ISO 9000 & QS 9000 series of quality standards. Sample Calibration Report.
Recalibration at regular intervals to document traceability to NIST is an important part of most quality programs such as the ISO 9000 series of quality standards.
If you do not have facilities to safely package your glass thermometers, we will loan you a case for shipping (no charge). Fax or email us the recalibration form, (be sure to check the ‘Please send me a shipping case!’ option), and indicate the length of each thermometer. We will send you via UPS a reusable shipping case into which you place the instruments (we’ll include instructions), snap the case closed, affix the supplied return label, and ship it back to us via the carrier of your choice. Your instruments will be returned to you, with calibration reports, in standard packaging.
Normally 5 to 7 working days at our facility. If you have an emergency, let us know and we will make certain your deadline is met.
We also offer a wide variety of NEW NIST Traceable calibrated thermometers, ASTM, SAMA and others, available for immediate shipment at competitive prices.