V-FOLD fed directly from DAF via slurry transfer pump with additional polyelectrolyte dosing at a cardboard manufacturer/printer. V-FOLD fed directly from Induced Air Flotation cell without intermediate pumping or polyelectrolyte addition at a ...
ByVfold Inc. based in London, ONTARIO (CANADA)
Heron Innovators provides a fully integrated Suspended Air Flotation (SAF) system for food and beverage processing facilities. ...
ByHeron Innovators, Inc. based in Rocklin, CALIFORNIA (USA)
Winery sludge pumped from Clarifier underflow directly to a V-FOLD filter without intermediate storage. Winery sludge float from Induced Air Flotation overflows directly to a V-FOLD without additional polyelectrolyte or intermediate storage. ...
ByVfold Inc. based in London, ONTARIO (CANADA)
Proper fluid and proppant placement are critical to a successful propped fracture stimulation treatment. Despite effective placement of the treatment, well performance is often detrimentally affected by incomplete gel breaking and fluid ...
ByPentair Filtration Solutions, LLC based in Conroe, TEXAS (USA)
Hydrocarbons in the sour water system are typically present on a continuous basis at up to 10,000 ppm and during upsets to levels greater than 50,000 ppm. As little as 5,000 ppm Cat Naphtha lost to the sour water system from an FCC main fractionator overhead accumulator operating at 100 gpm water represents 262,800 gallons of potential product gasoline lost per year, with a recoverable product value greater than ...
ByPentair Filtration Solutions, LLC based in Conroe, TEXAS (USA)
Glycol dehydration is a liquid desiccant system for the removal of water from natural gas and natural gas liquids (NGL). It is the most common and economic means of water removal from these streams.Glycols typically seen in industry include triethylene glycol (TEG), diethylene glycol (DEG), ethylene glycol (MEG), and tetraethylene glycol (TREG). TEG is the most commonly used glycol in ...
ByPentair Filtration Solutions, LLC based in Conroe, TEXAS (USA)
There are a number of factors that affect the capacity and operation of a typical amine system. Solid or liquid contaminants in the system may cause foaming. The presence of foaming is typically addressed by the addition of expensive antifoam chemicals and/or by reducing the operating capacity of the amine system. In addition to this, the presence of contaminants in the system can foul heat exchangers and column packing or trays. These solid and liquid contaminants are either ingressed into the system with the ...
ByPentair Filtration Solutions, LLC based in Conroe, TEXAS (USA)
A combination of factors in recent years has led to increased attention to water management in the oil and gas industry. Some of these factors include: limited water resources in certain areas, development of water-intensive technologies to better exploit unconventional plays, excessive transportation/disposal costs for water, a changing regulatory environment and a public push for sustainability and conservation relating to water as a ...
ByPentair Filtration Solutions, LLC based in Conroe, TEXAS (USA)