11 applications found

Research respirometer equipment for biodegratation kinetics of industrial wastes sector

Research respirometer equipment for biodegratation kinetics of industrial wastes sector

Samples of the industrial wastewater were collected and oxygen uptake for four dilutions was measured using a CHALLENGE AER-200 aerobic/anaerobic respirometer system. ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research respirometer equipment for biochemical oxygen demand measurement sector

Research respirometer equipment for biochemical oxygen demand measurement sector

TCMP was added to eliminate interference from nitrification. Oxygen uptake was measured over a five-day test period using a CHALLENGE AER-200 ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Pesticide Degradation

Research Respirometer Equipment for Pesticide Degradation

Measurement of oxygen uptake of the pesticides: carbaryl, carbofuran and aldicarb in samples seeded with microorganisms extracted from ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Industrial Waste Treatability Industry

Research Respirometer Equipment for Industrial Waste Treatability Industry

TCMP was added to inhibit nitrification. 25 mL of seed from a laboratory scale reactor was added to each test reactor. Oxygen uptake was monitored using a CHALLENGE AER-200 respirometer for five days. A second dose of 40 and 60 mL of leachate sample was then added to each reactor and oxygen uptake was measured for another 5 ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Measuring Oxygen Uptake Rates and Short-Term BOD

Research Respirometer Equipment for Measuring Oxygen Uptake Rates and Short-Term BOD

Measurement of oxygen uptake rates in activated sludge processes is essential to their satisfactory operation. Traditionally, oxygen uptake rates (OUR) have been determined by using a dissolved oxygen probe to measure the change in dissolved oxygen in a BOD bottle. While this method is rapid, it provides only a snapshot of the pattern of oxygen ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Monitoring the Activity of Mixed-Liquor Solids Sector

Research Respirometer Equipment for Monitoring the Activity of Mixed-Liquor Solids Sector

Sample Type: Mixed liquor solids from an activated sludge process MVLSS = 1320 ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Monitoring Treatment Plant Performance

Research Respirometer Equipment for Monitoring Treatment Plant Performance

Waste Type: Activated sludge process ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Toxicity Testing

Research Respirometer Equipment for Toxicity Testing

Waste Type: Complex alcohols. Objective: Certain constituents of the test waste were know to be biodegradable but were suspected of being toxic to aerobic biological processes when present in high concentrations. The objective was then to determine how much waste could be added to an activated sludge process before toxic impacts would be ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Testing the Stability of Compost Sector

Research Respirometer Equipment for Testing the Stability of Compost Sector

The reaction vessels were connected to a Challenge AER-200A respirometer system for measuring the oxygen ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Fermentation Off-Gas Analysis

Fermentation Off-Gas Analysis

Data is used for the calculation of the respiratory quotient, carbon production rate and oxygen uptake rate. The Off-Gas measurement provides the respiratory quotient in a time and space averaged form and with good response time. By comparison data from multiple dissolved species probes are more specific and can provide information about stirring efficiency, aeration and feed distribution within the fermentor. Dissolved gas measurements have ...

ByHiden Analytical Ltd.  based in  Warrington, UNITED KINGDOM


Fermentation Off-Gas Analysis

Fermentation Off-Gas Analysis

Data is used for the calculation of the respiratory quotient, carbon production rate and oxygen uptake rate. The Off-Gas measurement provides the respiratory quotient in a time and space averaged form and with good response time. By comparison data from multiple dissolved species probes are more specific and can provide information about stirring efficiency, aeration and feed distribution within the fermentor. Dissolved gas measurements have ...

ByHiden Analytical Ltd.  based in  Warrington, UNITED KINGDOM

  • Previous
  • 1
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT