Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Applications
  3. australia
  4. nitrification
Show results for
Products
Services
Applications

Companies


Refine by
Locations
Back to All Locations

  • Australasia
  • Australia
Industries served

  • Water and Wastewater
  • Monitoring and Testing
  • Waste and Recycling
  • Soil and Groundwater
  • Food and Beverage

Nitrification Product Applications In Australia

14 applications found
In AustraliaAvailable In AustraliaNear Australia

Wastewater systems solutions for activated sludge sector
Premium

Wastewater systems solutions for activated sludge sector

Odors need to be kept below the "neighbor noticing" threshold. Issues with nitrification / denitrification can easily become large permitting problems. ...

ByIxom Watercare  based in  Dickinson, NORTH DAKOTA (USA)


Research respirometer equipment for biochemical oxygen demand measurement sector

Research respirometer equipment for biochemical oxygen demand measurement sector

TCMP was added to eliminate interference from nitrification. Oxygen uptake was measured over a five-day test period using a CHALLENGE AER-200 ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Waste water respirometry solutions for toxicity tracking

Waste water respirometry solutions for toxicity tracking

The samples would be tested against the activated sludge of the receiving works, using the Respiration Inhibition Test or the Nitrification Inhibition ...

ByStrathkelvin Instruments Limited  based in  North Lanarkshire, UNITED KINGDOM


Research Respirometer Equipment for Chemical Production Wastewater Industry

Research Respirometer Equipment for Chemical Production Wastewater Industry

Oxidation of a third group of constituents - in this case thought to be nitrification - extends beyond six hours of contact. The test was terminated before the reaction was complete. ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Industrial Waste Treatability Industry

Research Respirometer Equipment for Industrial Waste Treatability Industry

Test Setup: 40 and 60 mL of wastewater were added to individual respirometer flasks each containing nutrient/mineral/buffer medium to form two different dilutions. TCMP was added to inhibit nitrification. 25 mL of seed from a laboratory scale reactor was added to each test reactor. ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Waste water respirometry solutions for toxicity reduction tests

Waste water respirometry solutions for toxicity reduction tests

An alternative approach is to undertake toxicity reduction procedures, such as neutralisation or acid hydrolysis, in pilot-scale laboratory studies. The Respiration or the Nitrification Inhibition Test may be used for this. In the future, toxicity reduction may be stipulated by local authority, water company or publicly-owned treatment works prior to giving discharge consents. ...

ByStrathkelvin Instruments Limited  based in  North Lanarkshire, UNITED KINGDOM


Water quality solutions for nitrification Chloramine areas
Premium

Water quality solutions for nitrification Chloramine areas

The Fast Response Early Boost (FREB) strategy has provided effective control in chloraminated potable water tanks during warm months when these problems are most ...

ByIxom Watercare  based in  Dickinson, NORTH DAKOTA (USA)


Technologies for Wastewater Treatment in Meat Processing Industry

Technologies for Wastewater Treatment in Meat Processing Industry

Fluence employs the following main technologies to design Waste & Wastewater treatment plants: DAF Dissolved Air Flotation: For the initial extraction of COD suitable for the anaerobic digestion Anaerobic digestion: For wastewater treatment and renewable energy generation Nitrification-denitrification process: For the final treatment of wastewater, in order to comply with regulations ...

ByFluence Corporation  based in  PLYMOUTH, NEW YORK (USA)


Waste water respirometry solutions for toxicity based consents

Waste water respirometry solutions for toxicity based consents

The tests used are the Respiration Inhibition Test and the Nitrification Inhibition Test. Note that this approach mirrors that of the regulators of discharges to receiving waters, who are now using direct toxicity tests (DTA) or whole effluent toxicity tests (WET tests) in order to protect the receiving ...

ByStrathkelvin Instruments Limited  based in  North Lanarkshire, UNITED KINGDOM


Research Respirometer Equipment for Monitoring the Activity of Mixed-Liquor Solids Sector

Research Respirometer Equipment for Monitoring the Activity of Mixed-Liquor Solids Sector

Sample Type: Mixed liquor solids from an activated sludge process MVLSS = 1320 ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Monitoring Treatment Plant Performance

Research Respirometer Equipment for Monitoring Treatment Plant Performance

Waste Type: Activated sludge process ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Pharmaceutical Wastewater Industry

Research Respirometer Equipment for Pharmaceutical Wastewater Industry

A pharmaceutical company was interested in knowing whether a specific component, MCB, inhibited the biodegradation of other wastewater constituents. A series of respirometer tests was set up using identical mixtures of wastewater and return activated sludge (RAS) plus varying amounts of MCB. The OUR fingerprint of this wastewater includes a first peak of about 500 mg/L-hr within the first hour of contact that represents the oxidation of highly-biodegradable organic constituents. A second group of readily ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Toxicity Testing

Research Respirometer Equipment for Toxicity Testing

Waste Type: Complex alcohols. Objective: Certain constituents of the test waste were know to be biodegradable but were suspected of being toxic to aerobic biological processes when present in high concentrations. The objective was then to determine how much waste could be added to an activated sludge process before toxic impacts would be ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Ammonia measurement in raw wastewater applications

Ammonia measurement in raw wastewater applications

The action of the micro-organisms on organic and complex inorganic materials, leads to the production of ammonia. When ammonia is present in water at high enough levels, it will have detrimental effects on animal life. For this reasons ammonia in a wastewater plant might be monitored and removed at different points in the process: Inflow of the WWTP - Raw wastewater intake (Using our MS3500). In the aeration lanes. At the outflow of the clarifier. At the works ...

ByMultisensor Systems Ltd.  based in  Cheadle, UNITED KINGDOM

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT