Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Applications
  3. poland
  4. digester
Show results for
Products
Services
Training
Applications

Companies


Refine by
Locations
Back to All Locations

  • Europe
  • Poland
Industries served

  • Water and Wastewater
  • Food and Beverage
  • Agriculture
  • Medical / Health Care

Digester Product Applications In Poland

32 applications found
In PolandAvailable In PolandNear Poland

Determination of total mercury content in blood by cvaas
Premium

Determination of total mercury content in blood by cvaas

INTRODUCTION Blood is one of the most complex substances for determination of the Hg content. At the same time, blood is the most important diagnostic medium used for monitoring the effect of Hg vapor on the human organism. In almost all the countries, personnel of mercury-involving production facilities are regularly examined for the Hg content in blood, which should not exceed 20–50 µg/l, whereas in the case of a person unexposed to mercury vapor the blood normally contains 1–3 µg/l of ...

ByLumex Instruments  based in  Mission, BRITISH COLUMBIA (CANADA)


Separation Layer Measurement in Primary Clarifier solutions for Wastewater Treatment Plant - Preclarification
Premium

Separation Layer Measurement in Primary Clarifier solutions for Wastewater Treatment Plant - Preclarification

Application: Rectangular basin 30 m x 8.5 m with two outlet funnels. Basin depth 2.8 m. Funnel depth 5.8 ...

ByNIVUS GmbH  based in  Eppingen, GERMANY


Total Mercury Determination in Water by CVAAS
Premium

Total Mercury Determination in Water by CVAAS

Introduction: The determination of mercury in water is one of the most frequently requested analyses for environmental, sanitary and technological purposes. Lumex Instruments RA-915M mercury analyzer, equipped with a special cold vapor accessory, can perform conventional cold vapor atomic absorption spectrometry (CVAAS) technique for the determination of mercury in surface, ground, drinking and waste water as well in atmospheric ...

ByLumex Instruments  based in  Mission, BRITISH COLUMBIA (CANADA)


Direct Total Mercury Determination in Water
Premium

Direct Total Mercury Determination in Water

Mercury determination in drinking and waste waters is one of the most popular analyses used for environment pollution and sanitary control, as this trace element is considered highly ...

ByLumex Instruments  based in  Mission, BRITISH COLUMBIA (CANADA)


Determination of the Chemical Oxygen Demand (COD) in Water
Premium

Determination of the Chemical Oxygen Demand (COD) in Water

Introduction: Chemical Oxygen Demand (COD) is one of the most common integral indicators of anthropogenic pollution of water bodies. COD is widely used in the analysis of natural water, to control wastewater treatment from organic various substances. ...

ByLumex Instruments  based in  Mission, BRITISH COLUMBIA (CANADA)


Mercury determination in natural, surface, sea, drinking, bottled, mineral, and waste water by cvaas
Premium

Mercury determination in natural, surface, sea, drinking, bottled, mineral, and waste water by cvaas

Introduction Mercury determination in natural, drinking, and waste waters is one of the most popular analyses used for environment pollution and sanitary control. Background concentrations of mercury in natural water are within several ng/l. Maximum national permissible levels for mercury in water lie in the range of 0.16–6 µg/l. For example, the following limits for mercury in drinking water are set, µg/l: 0.5 – Japan, Russia; 1 – Argentina, Australia, Brazil, China, EC; 2 ...

ByLumex Instruments  based in  Mission, BRITISH COLUMBIA (CANADA)


Direct mercury determination in coal
Premium

Direct mercury determination in coal

Introduction Mercury is one of the most toxic trace contaminant naturally occurring in the coals. During the coal combustion process at the coal-fired power plants mercury is released into the environment. To manage effectively the stack gas cleaning process, it is necessary to know the mercury content in the coal, and also in stack gas, liquid and solid ...

ByLumex Instruments  based in  Mission, BRITISH COLUMBIA (CANADA)


Flame Photometer for Measurement of Na, K and Ca in Plant Extracts

Flame Photometer for Measurement of Na, K and Ca in Plant Extracts

The most important ions which naturally occur in plant tissues are sodium, potassium, calcium, magnesium, nitrate, sulphate and phosphate. A sample of 5 g of oven-dried plant material contains on average, 25 mg calcium, 9 mg magnesium, 80 mg potassium and 3 mg sodium. The recommended method for the measurement of calcium is to precipitate the calcium as an oxalate, the precipitate is then dissolved and measurement taken from the resulting solution. Sodium and potassium may be measured directly following an ashing ...

ByBWB Technologies Ltd.  based in  Newbury, UNITED KINGDOM


Flame Photometer for Measurement of Calcium and Potassium in Cereals

Flame Photometer for Measurement of Calcium and Potassium in Cereals

Commercial cereals vary considerably in composition, both in their formulation and the ingredients added to enrich these products. Sodium is the predominant cation in breakfast cereals, at levels reaching 8mg/g. Potassium and calcium also vary, particularly in wheat-based products and those enriched with milk products or calcium salts. ...

ByBWB Technologies Ltd.  based in  Newbury, UNITED KINGDOM


Flame Photometer for Measurement of Calcium in Fresh Fruit

Flame Photometer for Measurement of Calcium in Fresh Fruit

In most cases, it was found that flame photometry was well suited for the determination of sodium, potassium and calcium in fresh fruits, using the wet ashing technique as given below. There are significant differences in the composition between different varieties of the same fruit, although these differences are not usually considered to be nutritionally ...

ByBWB Technologies Ltd.  based in  Newbury, UNITED KINGDOM


FT-NIR spectroscopy for the biofuels industry

FT-NIR spectroscopy for the biofuels industry

FT-NIR spectroscopy is a widely used technique that can do rapid and non-destructive measurements in seconds. This technique can achieve multiple analysis results per measurement and determine real–time chemical information at-line and ...

ByBruker Corporation  based in  Billerica, MASSACHUSETTS (USA)


Sludge monitoring for water and wastewater industry

Sludge monitoring for water and wastewater industry

Improved monitoring and automation can deliver more efficient waste treatment and reduced energy consumption and improved effluent quality. The cost of treatment and the quality of effluent discharge can thus be significantly ...

ByPollution & Process Monitoring Ltd  based in  Sevenoaks, UNITED KINGDOM

  • Previous
  • 1
  • 2
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT