Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Articles
  3. acoustic transducer
Show results for
Products
Services
Software
Applications

Companies

News
Articles
Downloads
Videos

Refine by
Date

  • This Year
  • Older

Acoustic Transducer Articles & Analysis

11 articles found

Transducer Biofouling: Preventing Silent Failure in Reservoir Ultrasonic Algae Control

Transducer Biofouling: Preventing Silent Failure in Reservoir Ultrasonic Algae Control

This only works when the full acoustic output reaches the water; a coated transducer cannot deliver it. ...

ByLG Sonic B.V.


Quantitative Analysis of Pulsed Ultrasonic Beam Patterns Using a Schlieren System

Quantitative Analysis of Pulsed Ultrasonic Beam Patterns Using a Schlieren System

Abstract The acoustic output from pulsed ultrasonic transducers has traditionally been analyzed with a hydrophone. ...

ByOnda Corporation


The Design of Broadband and Efficient Acoustic Wave Transducers

The Design of Broadband and Efficient Acoustic Wave Transducers

Abstract The basic design criteria for SAW transducers is typically a flat frequency response. design criteria for bulk wave transducers in nondestructive evaluation and medical imaging is the compactness of the impulse response. ...

ByOnda Corporation


A Novel Device for Total Acoustic Output Measurement of High Power Transducers

A Novel Device for Total Acoustic Output Measurement of High Power Transducers

Abstract A robust needle hydrophone has been developed for HIFU transducer characterization and reported on earlier [1]. After a brief review of the hydrophone design and performance, we demonstrate its use to characterize a 1.5 MHz, 10 cm diameter, F-number 1.5 spherically focused source driven to exceed an intensity of 1400 W/cm at its focus. Quantitative characterization of this source at high ...

ByOnda Corporation


KLN Transducer Model Implementation Using Transfer Matrices

KLN Transducer Model Implementation Using Transfer Matrices

The Krinholtz, Leedom, and Matthaei transmission line model for acoustic transducers has been implemented on an IBM PC-XT computer using transfer, or "ABCD" matrices. ...

ByOnda Corporation


An Edge-Bonded Surface Acoustic Wave Transducer Array

An Edge-Bonded Surface Acoustic Wave Transducer Array

Abstract A new type of transducer array has been designed and built for Imaging surface defect in metals such as aluminum. The array is formed by edge-bonding a piece of piezoelectric material to a substrate of the same material as the sample to be tested. The individual elements in the array are formed by photolithography, and each element acts as an edge-bonded surface wave transducer. The ...

ByOnda Corporation


Computer-Optimized Design of Quarter-Wave Acoustic Matching and Electrical Matching Networks for Acoustic Transducers

Computer-Optimized Design of Quarter-Wave Acoustic Matching and Electrical Matching Networks for Acoustic Transducers

We have developed an Iterative computer program to optimize the parameters for the acoustic matching layer(s) and the electrical matching network of a transducer for a minimum length of the impulse response. By including the Interactions between electrical and acoustic matching in our model » we have been able to significantly improve the ...

ByOnda Corporation


Fundamental Concepts In Acoustic Transducer Array Design

Fundamental Concepts In Acoustic Transducer Array Design

Abstract Ceramic strip resonators with rectangular cross-section have been made with aspect ratios (width to height ratios) from 0.1 to 30 . The short and open circuit resonant frequencies have been plotted as a function of aspect ratio and show good agreement between experiment and a simple coupled mode theory. The effect of loading these resonators acoustically with solids and liquids has also ...

ByOnda Corporation


Rare earth intermetallic compounds

Rare earth intermetallic compounds

At present, they are mainly used in the production of underwater acoustic transducers and electroacoustic transducers. Vibration control system, marine exploration and underground communication and other fields. Giant magnetostrictive materials are also used to manufacture intelligent vibration aging devices, ultrasonic ...

ByEdgetech Industries LLC


Flow Measurement Test At G. M. Shrum Powerplant - Case Study

Flow Measurement Test At G. M. Shrum Powerplant - Case Study

W. A. C. Bennet dam and G. M. Shrum generating station (GMS) are located on the Peace River in northeastern British Columbia, Canada. ...

ByASL AQFlow Inc.


Turbine flow measurement in intakes: a cost-effective alternative to measurement in penstocks - Case Study

Turbine flow measurement in intakes: a cost-effective alternative to measurement in penstocks - Case Study

Typical practice for turbine flow measurement has been to install instruments in the penstock, such as current meters (CM), acoustic time-of-flight transducers (ATF) or pressure-time taps (PT). At some plants, particularly those with buried penstocks, these methods have significant disadvantages, resulting in high costs. ...

ByASL AQFlow Inc.

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT