Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Articles
  3. bod control
Show results for
Products
Services
Applications

Companies

News
Articles
Books
Downloads
Videos

Refine by
Date

  • Older

Bod Control Articles & Analysis

52 articles found

Sugar Factory Wastewater Treatment Plant - Case Study

Sugar Factory Wastewater Treatment Plant - Case Study

A Sugar Factory Wastewater Treatment Plant Experiences a Large Reduction in BOD/COD Levels The Newterra® Aire-O2® Triton Systems provides a reliable, efficient solution in a challenging environment. The Sucrafor sugar-factory wastewater treatment plant was challenged to meet stringent Biochemical Oxygen Demand (BOD) and Chemical Oxygen Demand (COD) standards. In this corrosive ...

ByNewterra, Ltd.


Comprehensive recommendations for plastic recycling machines

Comprehensive recommendations for plastic recycling machines

The waste management of such materials will usually be the same as the recycling of the plastic material being processed. Emissions control involves the monitoring and control of air and water emissions. ...

ByYuyao Jiantai Plastic Machinery Co.


ETP Feeds With BactaServe   - Case Study

ETP Feeds With BactaServe - Case Study

With a presence in 138 countries on six continents, pharma company is now the world’s largest integrated supplier of solid dosage products and services – providing hard-shell capsules, film and foil barrier solutions. Founded in Mumbai, India in 1961,now serves pharmaceutical companies all over the world, touching almost every aspect of solid dosage ...

ByAmalgam Biotech


Optimizing Aeration Rate in Wastewater Treatment

Optimizing Aeration Rate in Wastewater Treatment

Therefore, DO sensors act like an insurance policy rather than a true process control tool. REAL-TIME COD/BOD MONITORING IMPROVES PROCESS CONTROL It is possible to complement the information gained by real-time DO levels with real-time BOD/COD data obtained at the effluent of primary clarification for a more effective aeration ...

ByUviTec, part of ABB (Formerly Real Tech Inc.)


Arrow Linen Supply Company - Case Study

Arrow Linen Supply Company - Case Study

Ceramic Microfiltration and Reverse Osmosis System Installation The video and images on this page showcase how Kemco Systems and Arrow Linen Supply partnered together to meet new county wastewater discharge compliance requirements. Arrow Linen Supplies Chief Engineer, Bob Boyle, speaks with Kemco’s Regional Sales Manager, Rick Warren, about his projects needs and why they chose Kemco. ...

ByKemco Systems - a CECO Environmental Company


Arrow Linen Supply Company - Case Study

Arrow Linen Supply Company - Case Study

Arrow Linen Supply Company is a 3rd Generation family run Food and Beverage Linen Laundry in the New York City area. In 2013 Arrow built a new plant in Garden City, NY, where at the time Nassau county had lenient limits on the discharge requirements of Arrow Linen. As the county updated their wastewater plans and regulations, it became apparent that Arrow Linen would fall under ...

ByKemco Systems - a CECO Environmental Company


optAER Fine-Bubble Aeration and in-Lagoon Upgrades - Case Study

optAER Fine-Bubble Aeration and in-Lagoon Upgrades - Case Study

Problem Your lagoon has served your community or company well for so long but now modern regulations or sludge buildup make it untenable. You don’t want to give up on your existing infrastructure, and more mechanical solutions require higher level operations training. The Nexom Answer optAER fine-bubble aeration and in-lagoon upgrades turn your lagoon into a modern treatment plant for ...

ByEnvironmental Dynamics International (EDI) - Axius Water


Integrating Aeration Control Solves Underperformance

Integrating Aeration Control Solves Underperformance

Robert Clinton, a paradigm shift is: “The change of a controlling perspective and the perceptive result of that change so that one perceives and understands reality in a different ...

ByEnvironmental Dynamics International (EDI) - Axius Water


Ferric Chloride Distribution, Phosphorus Reduction in a Wastewater Pond (ID36) - Wastewater Treatment System USCAWW-2803.001 - Case Study

Ferric Chloride Distribution, Phosphorus Reduction in a Wastewater Pond (ID36) - Wastewater Treatment System USCAWW-2803.001 - Case Study

Topics: wastewater, ammonia, energy savings, facultative, phosphorus, short-circuiting, treatment savings Overview: This is a municipal wastewater treatment system for the city. The system consists of a series of four ponds. Storage Pond #1 has a surface area of 1.3 acres, with a volume of 3.5 MG. Storage Pond #2 has a surface area of 4.2 acres, with a maximum depth of 12 ft, volume of about 10 ...

ByIxom Watercare


Improved Processing Performance in a Facultative Pond System- USINWW-LOC110.001 (ID32) - Case Study

Improved Processing Performance in a Facultative Pond System- USINWW-LOC110.001 (ID32) - Case Study

Topics: wastewater, sludge reduction, ammonia, MLSS/TSS, BOD, odor control, short-circuiting Overview: This is a facultative pond for the wastewater treatment plant (WWTP) serving a town of about 2,000. ...

ByIxom Watercare


Energy Savings, Mixing, & Odor Control- Industrial & Municipal Wastewater (ID168) - Wastewater Treatment Plant USCAWW-LOC465.001 - Case Study

Energy Savings, Mixing, & Odor Control- Industrial & Municipal Wastewater (ID168) - Wastewater Treatment Plant USCAWW-LOC465.001 - Case Study

Topics: wastewater ,industrial, complete mix, odor control, sludge reduction, energy savings Overview: This wastewater treatment plant (WWTP) consists of two separate treatment avenues for residential and industrial wastewater flows. ...

ByIxom Watercare


Improved BOD / CBOD / TSS Reduction & Energy Savings - USCAWW-LOC242.001 (ID157) - Case Study

Improved BOD / CBOD / TSS Reduction & Energy Savings - USCAWW-LOC242.001 (ID157) - Case Study

Topics: facultative, odor control, sludge, energy savings, sludge reduction, MLS/TSS Overview: This is a municipal wastewater treatment facility (WWTF) that serves the city. The wastewater system consists of 7 facultative ponds with initial biochemical oxygen demand (BOD) of about 550 mg/L and a continuous discharge rate of 2.8 MGD. Pond 1 is 85 acres in surface ...

ByIxom Watercare


Screening system enables plant to increase treatment capacity - Case Study

Screening system enables plant to increase treatment capacity - Case Study

Problem The activated sludge wastewater treatment plant in Kiel, Wis., treats high-strength wastewater from cheese production. When dissolved oxygen in the aeration basins dropped too low, the cheese waste influent was turned down or shut off. Operators wanted the plant to process more cheese waste, accept waste from septic haulers, increase biological treatment capacity, reduce biosolids costs, ...

ByDO2E Wastewater Treatment, LLC


Mixing for Better denitrification with less energy - Case study

Mixing for Better denitrification with less energy - Case study

Achieving simultaneous nitrification & denitrification in the same basin Topics: mixing, wastewater, activated sludge, energy savings, nitrification, denitrification System Overview: This basin is part of an activated sludge treatment plant serving 17,000 residents with an average influent of five (5) million gallons per day. Basin Build Information: Volume: 4 million gallons Type: ...

ByIxom Watercare


Detoxification of photo-catalytically treated 2-chlorophenol: optimization through response surface methodology

Detoxification of photo-catalytically treated 2-chlorophenol: optimization through response surface methodology

The present study was conducted to degrade and detoxify 2-chlorophenol (2-CP) under UV irradiation in the presence of titanium dioxide (TiO2) and hydrogen peroxide (H2O2). The treatment efficiency was evaluated on the basis of degradation and cytotoxicity reduction as well as biochemical oxygen demand (BOD), chemical oxygen demand (COD) and total organic carbon (TOC) removal. The process ...

ByIWA Publishing


Good Preparation and Planning Reduces Wastewater Headaches Associated with Production Outages

Good Preparation and Planning Reduces Wastewater Headaches Associated with Production Outages

Staggering machine shutdowns and tank cleaning dramatically control both hydraulic and BOD loading to the wastewater system, avoiding most serious problems during this part of the outage. But even with the best controls, BOD loading nearly always increases and can overload the existing biological population. ...

ByEnvironmental Business Specialists, LLC


Mixing To Enhance Facultative Wastewater Lagoon Treatment

Mixing To Enhance Facultative Wastewater Lagoon Treatment

SolarBee® & GridBee® Are Leading The Way In most lagoons, sunlight causes a hard stratification at 12 to 18 inches of depth. The top water is warmer and thick algae populations are producing supersaturated dissolved oxygen (DO). The DO gasses off at the surface and is not readily available deeper in the pond for use by BOD-reducing bacteria. Meanwhile new inflow water may be ...

ByIxom Watercare


Treatment and potential reuse of greywater from schools: a pilot study

Treatment and potential reuse of greywater from schools: a pilot study

This study presented performance data on a low cost and easy maintenance pilot system for on-site treatment and reuse of water collected from wash sinks and fountains, as major sources of greywater (GW) at schools. Various treatment options were studied including screening, sand filtration, chlorination, and UV disinfection operated at different flow rates. Results showed that filtration ...

ByIWA Publishing


Further Meat Processing: GEM + MBBR - Case Study

Further Meat Processing: GEM + MBBR - Case Study

Introduction A facility specializing in poultry processing with operations in roast beef, poultry and ham cook operations, was utilizing a moving bed bio film reactor (MBBR) for BOD reductions prior to discharge to the local municipality. Challenge The MBBR was designed without pretreatment prior to the biological process. Due to an increase in production and the introduction of the roast beef ...

ByClean Water Technology, Inc.


Plastic Recycling Industry - Case Study

Plastic Recycling Industry - Case Study

As the global community becomes more aware of the practices and benefits of reuse and recycling of plastics, they are also demanding that better controls be put in place by the manufacturers, corporations, environmental agencies and end users. ...

ByClean Water Technology, Inc.

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT