Refine by
Cooling Tower Testing Articles & Analysis
8 articles found
Industrial cooling towers are essential for heat rejection in many facilities but create conditions that favor Legionella proliferation. ...
The exponential growth of artificial intelligence, cloud computing, and edge computing infrastructure has pushed data center cooling systems to their operational limits. As facilities scale to meet unprecedented thermal loads, the traditional approach to data center cooling water treatment faces mounting challenges. These include persistent biofouling, Legionella contamination risks, mineral ...
Today, Operators Unlimited provides complete system management of the company’s three boilers and two cooling towers to accommodate the customer’s increasing water capacity.Boilers and cooling tower water require constant testing and monitoring to ensure that processes run efficiently, meet environmental ...
Just a few days of stagnant water sitting in your pipes or cooling tower are enough for certain pathogens to start growing. By ten days of stagnation, steps need to be taken to ensure the safe re-opening of water systems. ...
Just last August, about 120 people in the South Bronx were infected with Legionnaires’ Disease and 12 people died. At the time, up to 5 cooling towers in the area tested positive for Legionella, a fatal bacteria that grows in warm, damp environments and can spread once contaminated water has become aerosolized and the vapor is inhaled. ...
This paper presents the results of a study on electrogeneration of aluminium, as a coagulant to remove silica in make-up water for cooling towers. Three electrochemical systems were tested, two with aluminium electrodes (one with polarity change and another without it), and a third one with aluminium anodes and cathodes of stainless steel. ...
Misericordia Hospital – Alberta – 2011 In June, 2011 Misericordia Hospital began a three-month trial on two of the three cooling towers in its facility. The test compared the effectiveness of HydroFLOW in eliminating limescale and algae vs. standard chemical treatment. Standard chemical treatment was removed from ...
Since infection with Legionella occurs through inhaling the bacterium, any activity in which contaminated water can be misted and subsequently inhaled can lead to infection. Cooling towers, such as those used in large systems, as well as evaporative coolers, hot water systems, showers, whirlpool spas, decorative fountains, hot tubs, ice-making machines and room ...
