Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Articles
  3. flow velocity sensor
Show results for
Products
Services
Applications

Companies

News
Articles
Downloads
Videos

Refine by
Date

  • Older

Flow Velocity Sensor Articles & Analysis

17 articles found

How does a magnetic flow meter register water flow?

How does a magnetic flow meter register water flow?

Magnetic flow sensors convert the velocity of a flowing fluid, waters for example, into a measurable electrical signal that is proportional to the flow rate. ...

ByMass Flow Online B.V.


Seal The Deal: Shielding against a Mag meter`s Achilles Heel

Seal The Deal: Shielding against a Mag meter`s Achilles Heel

When it comes to metering water flow — drinking water or wastewater — full-bore mag meters offer many advantages. While the underlying technology based on Faraday’s Law of electromagnetic induction (Figure 1) is shared among all styles of full-bore mag meters, specific implementations have impacts on longevity and accuracy. Here is what to look for when the time to choose ...

ByMcCrometer, Inc. - Veralto


How has Industry 1.0 to 4.0 influenced particulate emissions and monitoring - Part 1: Industry 1.0

How has Industry 1.0 to 4.0 influenced particulate emissions and monitoring - Part 1: Industry 1.0

Introduction ENVEA have been at the forefront of environmental monitoring and process control over four decades and with the emergence of the Industrial Internet of Things (Industry 4.0) ENVEA are again providing innovative solutions which harness the potential of this new industrial era. In this series of articles, we will be exploring the relationship between industrialisation and ...

ByENVEA


Generation-next mass flowmeter arrives

Generation-next mass flowmeter arrives

By sensing the number of vortices per unit time passing by the velocity sensor, the flowmeter is able to compute the fluid's volumetric flow rate. ...

BySierra Instruments, Inc.


Advanced thermal dispersion mass flowmeters

Advanced thermal dispersion mass flowmeters

King who, in 1914 [1], published his famous King's Law revealing how a heated wire immersed in a fluid flow measures the mass velocity at a point in the flow. He called his instrument a "hot-wire anemometer." The first application of this technology was hot-wire and hot-film anemometers and other light-duty TD flow ...

BySierra Instruments, Inc.


New Developments in Thermal Dispersion Mass Flow Meters

New Developments in Thermal Dispersion Mass Flow Meters

King who, in 1914 [1], published his famous King’s Law revealing how a heated wire immersed in a fluid flow measures the mass velocity at a point in the flow. He called his instrument a “hot-wire anemometer.” The first application of this technology was hot-wire and hot-film anemometers and other light-duty thermal dispersion ...

BySierra Instruments, Inc.


Thurston County comments on Greyline Area-Velocity Flowmeters - Case Study

Thurston County comments on Greyline Area-Velocity Flowmeters - Case Study

We use both the Stingray portable flow meters and the permanent Area Velocity Flow Meter (AVFM II) in multiple stormwater applications. We have used these meters to measure stormwater flows to help our design engineers develop flow capacity for stormwater projects. ...

ByPulsar Measurement


Replacement of Defective EMF - Case Study

Replacement of Defective EMF - Case Study

Application Steel cast pipe with 700 mm diameter Full filled Existing EMF in pipeline defective Definition of tasks Cost-efficient installation of the new flow measurement Defective EMF should not be removed if possible (costs) No interruption of running processes Solution A permanent flow measurement transmitter Type NivuFlow 750 in ...

ByNIVUS GmbH


Calibration using 5 flow sensors saves the effort of extensive reconstruction measures

Calibration using 5 flow sensors saves the effort of extensive reconstruction measures

The NIVUS COSP technology is a method that permits to calibrate and to adjust flow velocity measurements even under poor flow conditions. This calibration can be carried out based on the cross correlation method using the new NivuFlow 750 M9 transmitter in combination with up to nine flow velocity ...

ByNIVUS GmbH


New Developments in Thermal Dispersion Mass Flow Meters: In-The-Field Compensation for Changes in Natural Gas Composition

New Developments in Thermal Dispersion Mass Flow Meters: In-The-Field Compensation for Changes in Natural Gas Composition

The method described in this paper solves the problem of variable composition via a new four-temperature mass flow sensor. The new (low sensor feeds its measurements into the algorithms of an advanced mathematical model that includes gas properties in its calculations. ...

BySierra Instruments, Inc.


Increase biogas production, aeration basin efficiency with the right flow meter

Increase biogas production, aeration basin efficiency with the right flow meter

Since a volumetric flow rate changes with variations in temperature and pressure, a volumetric flow meter, such as a typical orifice plate, must be compensated with additional temperature and pressure sensors and must use a flow computer to compute mass flow. ...

BySierra Instruments, Inc.


A new paradigm for thermal dispersion mass flowmeters

A new paradigm for thermal dispersion mass flowmeters

King who, in 1914, published his famous King’s Law2 revealing how a heated wire immersed in a fluid flow measures the mass velocity at a point in the flow. He called his instrument a “hot-wire anemometer,” and these instruments have been used in fluid mechanics research and as light-duty mass flowmeters and ...

BySierra Instruments, Inc.


Quarry Dewatering Compliance - Case Study

Quarry Dewatering Compliance - Case Study

Bray Construction installed a Greyline Area-Velocity Flow Meter in 2009 to meet Ministry of Environment regulations. ...

ByPulsar Measurement


Quarry dewatering compliance - Case Study

Quarry dewatering compliance - Case Study

Bray Construction installed a Greyline Area-Velocity Flow Meter in 2009 to meet Ministry of Environment regulations. ...

ByPulsar Measurement


Online measurement with OTT SLD and LogoSens2

Online measurement with OTT SLD and LogoSens2

Task Online measurement of water level and velocity of flow with subsequent discharge calculation according to the velocity-index-method. ...

ByOtt - Veralto


Advances in Thermal Dispersion Mass Flow Meters - Part 1 Principle of Operation

Advances in Thermal Dispersion Mass Flow Meters - Part 1 Principle of Operation

Abstract This paper describes an advanced microprocessor-based thermal dispersion mass flow meter that uses four temperature sensing elements in its flow sensor instead of the traditional two elements and has a dry velocity sensor that uses no potting materials instead of the traditional potted ...

BySierra Instruments, Inc.


Advances in Thermal Dispersion Mass Flow Meters - Part 2 Installation and Flow Calibration

Advances in Thermal Dispersion Mass Flow Meters - Part 2 Installation and Flow Calibration

Abstract Part 1 of this two-part series describes the principle of operation of a new microprocessor-based thermal dispersion mass flow meter that uses four temperature sensing elements in its flow sensor and has a dry velocity sensor. ...

BySierra Instruments, Inc.

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT