Refine by
Head Gate Articles & Analysis
8 articles found
Year: 2018 Running Gear: 2 Vertical shaft Francis turbines with synchronous generators Scope: Replacement of control system and exciters This hydroelectric plant is located in central MA on a highly developed river, with multiple hydro plants operating both upstream and downstream of the project. Originally constructed in 1918 by a local manufacturing company, the project today consists of ...
The term “Sealed Maintenance-Free,” in my opinion, is a marketing-driven term. In the early 1980’s, when telephone Private Branch Exchanges (PBX’s) were being deployed into customer premises, computer mainframes were migrating out of dedicated computer rooms, and smaller computers were being situated in occupied office space. Consequently, users were demanding that the ...
Description of 4 Inch Gate Valve: ZECO 4 inch gate valve is one of the most commonly used calibers. Gate valve in the line just switch effect, looks small, really small gate to pipeline protection as very important, although the gate valve switch is a long time, but the gate valve torque needed ...
The air flow results from the subatmospheric pressure downstream of the gate. The air entrained by the high-speed flow is supplied by the air vent. ...
This paper describes computational fluid dynamics (CFD) simulations conducted to investigate the effectiveness of N2 injection in an active panel and a sealed longwall gob area to prevent and suppress spontaneous heating of coal using various injection locations and flow rates. In the active panel simulations, a single longwall panel with a bleederless ventilation system was simulated. The ...
In the present work an experimental study was conducted to investigate the aeration efficiency of high-head gated circular conduits. Results showed that high-head gated circular conduits were effective for oxygen transfer. ...
( 2 ) Procedure ① operate theResilient Seated Gate Valve to the fully open position ② truncated after split gate control valves, vent pipe remaining media. ③ with the wrench to remove the resilient gate valve and the pipe connection flange bolts with the appropriate parts of the sling hitch valve with a suitable lifting device which ...
Hydrologic and hydraulic design of the new spillway and outlet works system, including detailed hydraulic design of: a principal spillway system encompassing a side channel ogee weir discharging to a concrete chute; two baffled jump basins for the stilling basins of the principal spillway and outlet works tunnel conduit; a 410-foot-wide rock cut auxiliary spillway; outlet works with diversion ...