Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Articles
  3. headspace sampler
Show results for
Products
Applications

Companies

News
Articles
Downloads
Videos

Refine by
Date

  • Older

Headspace Sampler Articles & Analysis

17 articles found

Flavor and Aroma Profile of Hops Using FET-Headspace on the Teledyne Tekmar Versa with GC/MS

Flavor and Aroma Profile of Hops Using FET-Headspace on the Teledyne Tekmar Versa with GC/MS

In this application note, the flavor profile of five types of hops will be identified using Full Evaporation Technique (FET) Headspace on a Teledyne Tekmar Versa Automated Headspace vial sampler connected to a GC/MS (Gas Chromatograph/Mass Spectrometer) for chromatographic separation and detection. ...

ByTeledyne Tekmar


Meeting the Korean Method ES 04605.3 for Formaldehyde with Static Headspace GC/MS

Meeting the Korean Method ES 04605.3 for Formaldehyde with Static Headspace GC/MS

Introduction The Korean Standard Method for Drinking Water ES 04605.3 requires static headspace with Gas Chromatograph/Mass Spectrometer (GC/MS) to monitor formaldehyde. The method is based on the derivatization of formaldehyde with O-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) to form the pentafluorobenzyl oximine compound within a static headspace vial. ...

ByTeledyne Tekmar


Meeting the Korean Method ES 04607.1 for Naphthalene with Static and Dynamic Headspace GC/MS

Meeting the Korean Method ES 04607.1 for Naphthalene with Static and Dynamic Headspace GC/MS

Introduction The Korean Standard Method for Drinking Water ES 04607.1 requires static headspace with GC/MS to monitor naphthalene. The Minimum Quantitation Limit (MQL) must be less than 3 ppb. ...

ByTeledyne Tekmar


Meeting the Korean Method ES 04602.1b for Vinyl Chloride, Acrylonitrile, and Bromoform with Static and Dynamic Headspace GC/MS

Meeting the Korean Method ES 04602.1b for Vinyl Chloride, Acrylonitrile, and Bromoform with Static and Dynamic Headspace GC/MS

Introduction The Korean Method ES 04602.1b requires either static or dynamic headspace with GC/MS to monitor vinyl chloride, acrylonitrile, and bromoform. ...

ByTeledyne Tekmar


Meeting the Korean Method ES 04603.2b for 12 VOC with Static and Dynamic Headspace GC/MS

Meeting the Korean Method ES 04603.2b for 12 VOC with Static and Dynamic Headspace GC/MS

Introduction The Korean Standard Method for Drinking Water ES 04603.2b requires static headspace with GC/MS to monitor 12 Volatile Organic Compounds (VOCs). The Minimum Quantitation Limit (MQL) must be less than 5 ppb. ...

ByTeledyne Tekmar


Meeting the Korean Method ES 04601.2 for 1,4-Dioxane with Static Headspace GC/MS

Meeting the Korean Method ES 04601.2 for 1,4-Dioxane with Static Headspace GC/MS

Introduction The Korean Method ES 04601.2 requires static headspace with GC/MS to monitor 1,4-dioxane. The Minimum Quantitation Limit (MQL) must be less than 1 ppb. ...

ByTeledyne Tekmar


Blood alcohol content analysis using nitrogen carrier gas

Blood alcohol content analysis using nitrogen carrier gas

The large number of samples and requirement for speed of sample processing mean that analysis needs to be conducted quickly, whilst giving reliable and accurate results. For analysis of BAC, headspace GC with FID detection is typically used. Headspace GC allows the quantitative analysis of alcohol directly from blood samples. Standard ...

ByPEAK Scientific Instruments Ltd


Headspace gas chromatography with flame ionization detection (HS-GC-FID) for the determination of dissolved methane in wastewater

Headspace gas chromatography with flame ionization detection (HS-GC-FID) for the determination of dissolved methane in wastewater

This paper presents such a method, using gas chromatography with flame ionization detection fitted with a GS-Gas PRO column coupled with a headspace auto sampler. A practical limit of detection for methane of 0.9 mg L−1, with a retention time of 1.24 min, was obtained. ...

ByIWA Publishing


Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS

Quantitative Determination of Volatile Organic Compounds in Drinking Water by EPA Method with Headspace Trap GC-MS

Environmental Protection Agency (EPA) has developed a standard method, namely EPA 524.3 to identify and quantify the purgeable organic compounds in finished drinking water by using purge-and-trap with GC-MS. Headspace with trap mode could serve as an alternative option in analysing the purgeable VOCs. During incubation, VOCs from water samples are effectively partitioned into ...

ByShimadzu Scientific Instruments Inc


Alcoholic Beverage Fusel Alcohol Testing with Static Headspace

Alcoholic Beverage Fusel Alcohol Testing with Static Headspace

Abstract A static headspace method was developed using Teledyne Tekmar automated headspace vial samplers (Figure 1 and Figure 2) to meet the method requirements of the Alcohol and Tobacco Tax and Trade Bureau of the US Department of the Treasury (TTB) method SSD: TM:2001 for testing fusel alcohols in alcoholic beverages. ...

ByTeledyne Tekmar


Achieving low-level detection of benzene in beverages with an automated headspace vial sampler

Achieving low-level detection of benzene in beverages with an automated headspace vial sampler

Abstract Eight commercially available beverage samples were selected for low-level detection of benzene by static headspace analysis. This study will use the Teledyne Tekmar HT3 Automated Headspace Vial Sampler to analyze parts per trillion (ppt) levels of benzene in beverages. ...

ByTeledyne Tekmar


Achieving ppt Levels of environmental volatiles with a new Headspace Sampler

Achieving ppt Levels of environmental volatiles with a new Headspace Sampler

Introduction This study focuses on the Versa Automated Headspace Analyzer and its ability to analyze Volatile Organic Compounds (VOCs) in water at the part per trillion (ppt) level. Read the full article Click ...

ByTeledyne Tekmar


Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers

Methanol in Biodiesel by EN14110 with the HT3 and Versa Automated Headspace Analyzers

One of these qualifications, methanol content, is determined by EN 141103 , a headspace-gas chromatography method. This application note will present data for two different automated headspace vial samplers to meet the performance criteria outlined in EN Method 14110. ...

ByTeledyne Tekmar


Blood Alcohol Determination with the Teledyne Tekmar HT3 and Young Lin YL6500 Gas Chromatograph

Blood Alcohol Determination with the Teledyne Tekmar HT3 and Young Lin YL6500 Gas Chromatograph

Introduction Police and forensic laboratories around the world routinely use headspace-gas chromatography for volatile components in biological fluids. One of the more common headspace analyses is the determination of blood alcohol in cases involving suspected DUI or OVI. ...

ByTeledyne Tekmar


Residual Solvents Testing per ASTM F1884-04 with the Versa and HT3 Automated Headspace Sampler

Residual Solvents Testing per ASTM F1884-04 with the Versa and HT3 Automated Headspace Sampler

Introduction Police and forensic laboratories around the world routinely use headspace-gas chromatography for volatile components in biological fluids. One of the more common headspace analyses is the determination of blood alcohol in cases involving suspected DUI or OVI. ...

ByTeledyne Tekmar


Alternative Methods to RSK 175 Using Purge and Trap Concentration and Automated Headspace for the Analysis of Dissolved Gases in Drinking Water

Alternative Methods to RSK 175 Using Purge and Trap Concentration and Automated Headspace for the Analysis of Dissolved Gases in Drinking Water

Introduction Police and forensic laboratories around the world routinely use headspace-gas chromatography for volatile components in biological fluids. One of the more common headspace analyses is the determination of blood alcohol in cases involving suspected DUI or OVI. ...

ByTeledyne Tekmar


Determination of VOCs in water using static headspace GC/MS with simultaneous full scan and selective ion recording

Determination of VOCs in water using static headspace GC/MS with simultaneous full scan and selective ion recording

The combination of static headspace sample introduction and gas chromatography/mass spectrometry (HS/GC/MS) provides the analyst with a powerful, fully automated technique for the determination of trace volatile organic compounds (VOCs) in water. Samples may be hermetically sealed in the headspace vial at the point of sampling. This approach avoids errors due to ...

ByPerkinElmer, Inc.

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT