Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Articles
  3. icp sample preparation
Show results for
Products
Applications

Companies

Articles
Downloads

Refine by
Date

  • Older

Icp Sample Preparation Articles & Analysis

9 articles found

Application of R3/R5 Microwave Digestion Systems in the Elemental of American Ginseng

Application of R3/R5 Microwave Digestion Systems in the Elemental of American Ginseng

In this study, we follow the pharmacopoeia guidelines and apply microwave digestion for sample preparation, combined with ICP-MS (inductively coupled plasma mass spectrometry) for the determination of heavy and toxic elements in American ginseng. ...

ByTianezk Instrument Manufacturing (Chengdu) Co., Ltd.


Application Report Cement (Fused Beads with VITRIOX ELECTRIC)

Application Report Cement (Fused Beads with VITRIOX ELECTRIC)

In the cement industry, x-ray fluorescence analysis (XRF) is one of the major techniques employed for raw material and final product quality control. Typically, "pressed pellet" sample preparation is used; however, the disadvantage to this is that this technique shows only relative data to known and accepted reference methods like fusion or wet chemistry and takes no account of the different ...

ByFluxana GmbH Co. KG


TIMS or MC-ICP-MS – which do i need?

TIMS or MC-ICP-MS – which do i need?

One of the main reasons for this is the hugely simpler sample preparation. ICP-MS instruments most commonly analyse samples in a dilute acid matrix, and for some sample types, the sample preparation is simply a case of diluting the sample to a suitable ...

ByIsotopx Ltd


What is laser ablation and why you need a nitrogen generator

What is laser ablation and why you need a nitrogen generator

Laser ablation is a process in which a laser beam is used to remove a portion of mass from a sample, usually as a sampling method for isotopic or elemental analysis of a solid sample. ...

ByPEAK Scientific Instruments Ltd


Multicollector ICP-MS with a Desolvating Nebulizer System for U-Series Dating of Late Pleistocene Terrestrial Snails

Multicollector ICP-MS with a Desolvating Nebulizer System for U-Series Dating of Late Pleistocene Terrestrial Snails

For useful measurement of low abundant isotopes and mass-limited samples, signal enhancement is often required. In addition, sample preparation and/or sample aerosol desolvation may be necessary to reduce or eliminate mass spectral interferences such as oxides and hydrides. This poster will examine the application of MCICP-MS ...

ByTeledyne CETAC Technologies


Multicollector ICP-MS with a Desolvating Nebulizer System for U-Series Dating of Late Pleistocene Terrestrial Snails

Multicollector ICP-MS with a Desolvating Nebulizer System for U-Series Dating of Late Pleistocene Terrestrial Snails

For useful measurement of low abundant isotopes and mass-limited samples, signal enhancement is often required. In addition, sample preparation and/or sample aerosol desolvation may be necessary to reduce or eliminate mass spectral interferences such as oxides and hydrides. This poster will examine the application of MCICP-MS ...

ByTeledyne CETAC Technologies


Measurement of trace metals in ambient air: Validation of a rapid technique with gold standard ICP-AES

Measurement of trace metals in ambient air: Validation of a rapid technique with gold standard ICP-AES

The gold standard metal measurement is Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES); however, sample preparation is laborious and expensive. The Xact 625 metals monitor uses non-destructive X-ray fluorescence technology. A built-in sample collection system enables near-real-time trace metal measurements in ...

ByCooper Environmental / Sailbri Cooper Inc.


Measurement of Trace metals in Ambient air - Validation of a Rapid Technique with Gold Standard ICP-AES - Case Study

Measurement of Trace metals in Ambient air - Validation of a Rapid Technique with Gold Standard ICP-AES - Case Study

The gold standard metal measurement is Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES); however, sample preparation is laborious and expensive. The Xact 625 metals monitor uses non-destructive X-ray fluorescence technology. ...

ByCooper Environmental / Sailbri Cooper Inc.


Comparing Field Portable X-Ray Fluorescence (XRF) To Laboratory Analysis Of Heavy Metals In Soil

Comparing Field Portable X-Ray Fluorescence (XRF) To Laboratory Analysis Of Heavy Metals In Soil

Suppose we wish to compare two atomic spectrometry methods, AAS and ICP-AES. The sample preparation is identical; both require sample digestion. ...

ByThermo Scientific Niton Analyzers

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT