Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Articles
  3. iron filter
Show results for
Products
Services
Applications

Companies

News
Articles
Books
Downloads
Videos

Refine by
Date

  • Older

Iron Filter Articles & Analysis

34 articles found

Magnetic Filters Reduce the Bacterial Count in Cooling Lubricant

Magnetic Filters Reduce the Bacterial Count in Cooling Lubricant

Optimisation of Cast Iron Machining using FRIESS Magnetic Filters Casting iron parts are regularly machined at a production company. ...

ByFriess GmbH


Water Treatment- Case Study

Water Treatment- Case Study

These Projects handle the Designing and installment/Building of facilities that handle varying operations such as Sand Separation, Conversion of Denim Plant to Reverse Osmosis, Iron,Manganese, and Activated Carbon Filters. Where Water System Rentals are also an ...

ByCavtech Multi-Resources Technology Inc.


Magnetic Filters Reduce the Bacterial Count in Cooling Lubricant

Magnetic Filters Reduce the Bacterial Count in Cooling Lubricant

Optimisation of Cast Iron Machining using Friess Magnetic Filters Casting iron parts are regularly machined at a production company. ...

ByFriess GmbH


Residential Bacterial Well Water, Minnesota, USA - Case Study

Residential Bacterial Well Water, Minnesota, USA - Case Study

The home is served by well water plagued with Iron Bacteria that yielded a “Swampy” odor in the water. ...

ByArgonide Corporation


Electromagnetic Filters for Ceramics

Electromagnetic Filters for Ceramics

Since the first ceramics were produced, iron and iron-bearing minerals have caused defects. The problematic minerals occur naturally in the raw materials, with additional fine iron accidentally introduced during transportation, storage or processing. ...

ByBunting - Redditch


15 Magnetic Liquid Filters Capture Iron in Orange Juice

15 Magnetic Liquid Filters Capture Iron in Orange Juice

Over an 18 month period, Bunting supplied 15 Magnetic Liquid Filters to Spanish citrus juice producers. The magnetic separators have ultra-strong Rare Earth Magnets which attract, hold and thus separate any fine iron present in the fruit juice. Fine Iron Contamination in Orange Juice Although, to many, the thought of food contaminated by metal ...

ByBunting - Redditch


Can a Water Softener Cause a High Water Bill?

Can a Water Softener Cause a High Water Bill?

How often your water softener will flush itself out with fresh water depends on a variety of factors: The hardness level of your water before filtering The iron level (if any) before filtering The pH level before filtering How many people in your household Tank capacity Generally speaking, the harder the water, the more ...

ByAlert Labs Inc.


3 Municipalities That Use AdEdge Solutions to Reduce Their Manganese - Case Study

3 Municipalities That Use AdEdge Solutions to Reduce Their Manganese - Case Study

Raw water is pretreated with hypochlorite before it reaches the filtration systems, which are located 20 feet below the memorial in a secured concrete vault. The systems then oxidize and filter manganese and iron using a proprietary, NSF 61-certified, granular ferric oxide media. ...

ByChartWater™ - A Chart Industries Company


Stocking up filtration equipment for marine expeditions

Stocking up filtration equipment for marine expeditions

We are proud to have our membrane filters take part in the adventure. Our customers utilize silver, glass fiber, and polycarbonate track etch (PCTE) membrane filters in aquatic research.1, 2, 3 These filters travel the seven seas, treating collected sea water samples for retention and analyses of algae, microorganisms, and microscopic ...

BySterlitech Corporation


Extensive Solutions for Removing Arsenic from Your Drinking Water

Extensive Solutions for Removing Arsenic from Your Drinking Water

When this happens, arsenic that would otherwise not be filtered through an ordinary filtration process will have coagulated enough to be caught in the filters. Iron is especially effective in allowing arsenic to coagulate, so many filtration systems rely on the use of iron. ...

ByChartWater™ - A Chart Industries Company


Treatment of arsenic-contaminated water using in-line electrolysis, co-precipitation and filtration in Costa Rica

Treatment of arsenic-contaminated water using in-line electrolysis, co-precipitation and filtration in Costa Rica

The system utilised in-line electrochlorination to oxidise water constituents without the need for external chemical supply. The oxidised arsenic and iron co-precipitated and were filtered via Greensand Plus™. The filter was catalytically active and provided an emergency oxidant. ...

ByIWA Publishing


World War II Memorial, DC Iron & Manganese Reduction - Case Study

World War II Memorial, DC Iron & Manganese Reduction - Case Study

Each treatment train includes an AdEdge AD26 iron removal system and an Arsenic Package Unit (APU) for arsenic treatment to attain the stringent discharge limits. ...

ByChartWater™ - A Chart Industries Company


Limited effectiveness of household sand filters for removal of arsenic from well water in North Vietnam

Limited effectiveness of household sand filters for removal of arsenic from well water in North Vietnam

Since well water utilized for domestic purposes in the Red River Delta of North Vietnam has been reported to be polluted by arsenic, barium, iron, and manganese, household sand filters consisting of various components are used. ...

ByIWA Publishing


One step, low pH iron and organics removal - Case Study

One step, low pH iron and organics removal - Case Study

Element/Weight Percentage Carbon: 43.56 Oxygen: 30.86 Sulfur: 1.79 Iron: 18.16 Calcium: 0.69 Silicon: 4.66 Aluminum: 0.28 Figure 2. Chromatic Elemental Imaging (top) and Energy Dispersive X-ray table (bottom) confirming the presence of iron on the membrane surface Cleaning Study A cleaning trial in the Avista laboratory confirmed the effectiveness of RoClean ...

ByKurita America Inc.


The role of backwash in start-up of full-scale drinking water biofilters

The role of backwash in start-up of full-scale drinking water biofilters

During start-up, finished water quality is secondary, detachment of microorganisms must be minimized, dust present in the original filter media must be removed and inherent inoculation of the biofilter with water used for backwashing must be considered. Investigations over a 9-week start-up period at a full-scale waterworks showed a strong correlation between suspended solids and ...

ByIWA Publishing


Kinetico Incorporated fact sheet

Kinetico Incorporated fact sheet

RESIDENTIAL/COMMERCIAL PRODUCTS Water conditioners Water softeners Drinking water systems (reverse osmosis) Carbon filters Waterplants (combined conditioner/drinking water system) Backwashing filters Aeration systems Iron filters Neutralizers Combination filters/softeners INDUSTRIAL SYSTEMS ...

ByKinetico Europe ApS - an Axel Johnson Company


Data normalization identifies performance issues - Case Study

Data normalization identifies performance issues - Case Study

The operators were pleased to see the membrane flux and rejection restored after the clean. Iron Filter Inspection Based on the amount of foulant removed and the increased cleaning frequency at the site, Avista recommended a complete physical inspection of the iron filters. The examination revealed a catastrophic failure of the ...

ByKurita America Inc.


In-depth analysis of changes restores system optimization - Case Study

In-depth analysis of changes restores system optimization - Case Study

At the same time, another borehole source was added doubling the feed conductivity and introducing a higher level of iron to the feed. EXD of Cartridge filter fouling showing CO and Fe as predominant components suggesting organic material and iron. The first sign of the change was rapid clogging of guard cartridge filters on ...

ByKurita America Inc.


Performance of diatomite/iron oxide modified nonwoven membrane used in membrane bioreactor process for wastewater reclamation

Performance of diatomite/iron oxide modified nonwoven membrane used in membrane bioreactor process for wastewater reclamation

This study describes an approach for surface modification of a nonwoven membrane by diatomite/iron oxide to examine its filterability. Analysis results showed that nonwoven hydrophilicity is enhanced. ...

ByIWA Publishing


Assessment of manganese removal from over 100 groundwater treatment plants

Assessment of manganese removal from over 100 groundwater treatment plants

Multivariate statistics indicated that multiple parameters including NH4+ removal efficiency, iron loading per filter run (FR) and pH of filtrate play a significant role in manganese removal, while other parameters (oxygen concentration in filtrate, filtration rate and empty bed contact time (EBCT)) were found to be of secondary importance. Univariate ...

ByIWA Publishing

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT