Passive Electrode Cable Articles & Analysis
12 articles found
The foundation used the SuperSting R8 Wi-Fi with 56 electrodes and passive cables spaced at five meters as well as the EarthImager 2D with a finite element inversion model of dipole-dipole electrode array data. ...
AGI’s instruments make finding this water simple: Instead of going the traditional route (installing electrodes in the ground and surveying), this method involved measuring resistivity via sinking marine cables. ...
Process The client used the SuperSting R8 and set out a line of 84 electrodes spaced 12.5 meters apart to measure resistivity and induced polarization (IP) using a dipole-dipole electrode array. ...
AGI’s Multi-Electrode Switch Box is an accessory to the SuperSting Wi-Fi. It allows the SuperSting Wi-Fi to automatically control and switch passive electrodes connected by a passive multi-electrode cable for automatic data acquisition in 2D, 3D, and 4D surveys. ...
Process The determination of site characterization was performed by AGI SuperSting Wi-Fi R8/IP/SP instrument with 42 electrodes and 3 meters electrode spacing with a mixed array of dipole-dipole and Schlumberger The data Processing with EarthImager 2D software. ...
Groundwater Exploration Techniques & Process Using our SuperSting R8/IP with a SwitchBox 84, an AGI resistivity imaging cable, and electrode stakes with attachment spring, the Engineers Brigade combined dipole-dipole, Schlumberger, and pole-dipole arrays at 20 meters of spacing for 646 meters exploration depth through the savanna to image below the surface. ...
The client used the SuperSting R8/IP, the SwitchBox 112, and 112 electrodes installed in a seven-foot-by-six-foot 3D grid to map an area outside of the fenced gravesite area for anomalies. ...
Process Our clients used the SuperSting R8 Wi-Fi with a SwitchBox 112, passive cables spaced at six meters apart, and a dipole-dipole and strong gradient array. ...
Klaza property in Yukon Territory, Canada Equipment: SuperStingR8 with AGI 84 electrode passive electrical imaging cable, 5 meter electrode spacing, inverse schlumberger array, boost mode(200W output), Direct Samples: Reverse circulation drilling and geochemical analysis of core samples. ...
AGI’s instruments make finding this water flow simple: Instead of going the traditional route (installing electrodes in the ground and surveying), this method involved measuring resistivity via floating marine cables. ...
The client used the SuperSting R8 with 112 total electrodes arranged in a 4-by-28 electrode 3D grid with 16-foot-by-eight-foot spacing to map electrical conduction and locate the spots of leakage and an anomaly, which turned out to be a sinkhole. ...
Process We used SuperSting R8 Wi-Fi with 28 electrodes spaced one meter apart on a passive electrode imaging cable to measure the resistance of the soil using the dipole-dipole and inverse Schlumberger array. ...