Selective Electrode Articles & Analysis

55 articles found

Mag Flow Water Meter in Pulp and Paper Making

Mag Flow Water Meter in Pulp and Paper Making

As the cooking solution for alkali such as Ca (OH) 2 or Na0H solution, the slurry are alkaline, so the electromagnetic flowmeter is mostly used in high-temperature-resistant polytetrafluoroethylene lining and split-type structure type. In the choice of electrode materials to consider the selection of corrosion-resistant materials. ...

ByARTang Group


Choosing the Right Electromagnetic Flowmeter Model?

Choosing the Right Electromagnetic Flowmeter Model?

PU offers excellent resistance to wear and corrosion and is often used for measuring media containing particulate matter and exhibiting some corrosiveness, such as sewage. Consider the electrode material: The electrode comes into direct contact with the measured medium, so the appropriate material must be selected based on the medium's ...

ByARTang Group


What is the applicable of split electromagnetic flowmeter?

What is the applicable of split electromagnetic flowmeter?

Corrosive liquid: Since only the lining and electrodes of the sensor part are in contact with the measured liquid, as long as the electrode and lining materials are reasonably selected, the split electromagnetic flowmeter can be used to measure corrosive liquids. 2. ...

ByARTang Group


Large-caliber electromagnetic flowmeter

Large-caliber electromagnetic flowmeter

Corrosiveness The chemical properties of the measured fluid are crucial to the material selection of the electromagnetic flowmeter. If the fluid is highly corrosive, such as acid, alkali or salt solution, corrosion-resistant electrode materials and lining materials need to be selected. ...

ByARTang Group


Application of electromagnetic flowmeter

Application of electromagnetic flowmeter

The detection part mainly includes electrodes and interference adjustment parts. Since the electrodes are in direct contact with the measured medium, they must have strong corrosion resistance. ...

ByARTang Group


Selection of Electromagnetic Water Meter

Selection of Electromagnetic Water Meter

At the same time, some liquids can penetrate PTFE, causing short circuits and corrosion to flowmeter components; ②PFA, which has lower permeability than PTFE, but is easily deformed when temperature and pressure change; ③Ceramic, which is suitable for a variety of application conditions, but this material is sensitive to temperature fluctuations and pipe stress; ④Rubber, neoprene or natural ...

ByARTang Group


Several commonly used flow meter selection

Several commonly used flow meter selection

The minimum flow rate that can be measured by a vortex flowmeter is limited by the Reynolds number, the flow rate of the fluid and the signal-to-noise ratio (frequency interference). Vortex flowmeter selection 1. When selecting the flowmeter, the minimum measurable flow rate value of the selected flowmeter should be lower than the minimum flow ...

ByARTang Group


Selection of Magnetic Inductive Flow Meters in the Chemical Industry

Selection of Magnetic Inductive Flow Meters in the Chemical Industry

The normal operating flow rate should be at least 50% of the meter’s full-scale range to ensure accurate measurement. 3. Electrode and Lining Selection For media that do not cause crystallization, caking, or scaling on the electrodes, standard electrodes should be used. Otherwise, scraper electrodes are ...

ByARTang Group


Magnetic Inductive Flow Meters in the Chemical

Magnetic Inductive Flow Meters in the Chemical

The normal operating flow rate should be at least 50% of the meter’s full-scale range to ensure accurate measurement. 3. Electrode and Lining Selection For media that do not cause crystallization, caking, or scaling on the electrodes, standard electrodes should be used. Otherwise, scraper electrodes are ...

ByARTang Group


Selection of split type and flange electromagnetic flow meter

Selection of split type and flange electromagnetic flow meter

However, installation and wiring must be done carefully to avoid signal interference. The electrode material should be selected based on the corrosiveness of the measured medium. ...

ByARTang Group


Selection of Magnetic Inductive Flow Meters in the Chemical Industry

Selection of Magnetic Inductive Flow Meters in the Chemical Industry

The normal operating flow rate should be at least 50% of the meter’s full-scale range to ensure accurate measurement. 3. Electrode and Lining Selection For media that do not cause crystallization, caking, or scaling on the electrodes, standard electrodes should be used. Otherwise, scraper electrodes are ...

ByARTang Group


Application and Selection of Electromagnetic Flow Meters in the Pulp and Paper Industry

Application and Selection of Electromagnetic Flow Meters in the Pulp and Paper Industry

Additionally, adding a necked grounding ring during installation can greatly improve the wear resistance of the liner. Selection of Electrodes When selecting electrodes for electromagnetic flow meters in the papermaking industry, two main factors are considered: corrosion resistance and scaling prevention. ...

ByARTang Group


How Should I Select A Wastewater Electromagnetic Flow Meter?

How Should I Select A Wastewater Electromagnetic Flow Meter?

Selecting a wastewater electromagnetic flow meter involves considering several key factors to ensure accurate and reliable measurement. ...

ByARTang Group


What Materials are used in the Electromagnetic Flow Meter Boby?

What Materials are used in the Electromagnetic Flow Meter Boby?

Applications: Used in slurry applications where abrasion is a concern. 3. Electrode Materials: Electrodes are in direct contact with the fluid and must be conductive and resistant to corrosion. ...

ByARTang Group


What Materials are used in the Electromagnetic Flow Meter Boby?

What Materials are used in the Electromagnetic Flow Meter Boby?

Applications: Used in slurry applications where abrasion is a concern. 3. Electrode Materials: Electrodes are in direct contact with the fluid and must be conductive and resistant to corrosion. ...

ByARTang Group


Industrial wastewater flow monitoring in the selection of flow meters

Industrial wastewater flow monitoring in the selection of flow meters

In practical applications, in order to prevent the sewage containing solid particles on the lining and electrode wear, the general selection of the sensor caliber is relatively large, and the flow rate of 3m / s below is appropriate, but in order to ensure the symmetrical distribution of the flow rate, to try to extend the length of the upstream and downstream ...

ByARTang Group


Achieving Precision in Argon Gas TIG Welding

Achieving Precision in Argon Gas TIG Welding

Introduction Argon gas TIG welding, or Tungsten Inert Gas welding, is a specialist technique known for its precision and clean welds. Unlike other welding processes, TIG welding utilises a non-consumable tungsten electrode, and argon gas plays a pivotal role in shielding the weld from atmospheric contaminants. Precision in welding is crucial, particularly in industries where the integrity of the ...

ByCambridge Sensotec Limited


Electromagnetic flow meter in the sewage treatment plant applications

Electromagnetic flow meter in the sewage treatment plant applications

Comprehensive consideration. 1 caliber selection According to the sewage treatment plant to provide the caliber of the process pipeline, pipeline pressure and sewage flow, select the caliber of D = 600mm electromagnetic flowmeter, the site does not need to shrink and expand the pipeline. 2 lining, electrode material selection ...

ByARTang Group


Selection of flowmeters in sewage treatment

Selection of flowmeters in sewage treatment

Electromagnetic flowmeters and ultrasonic flowmeters are alternative options for flowmeter selection in sewage treatment units. For specific sewage treatment units, electromagnetic flowmeters and ultrasonic flowmeters should be flexibly selected according to actual working conditions, such as pipeline diameter, required measurement accuracy, etc., to achieve ...

ByARTang Group


Celdar Technology - Boron Removal - Case Study

Celdar Technology - Boron Removal - Case Study

The customer asked us to evaluate the Electrocoagulation for the removal of Boron and to be able to drain the treated water into the sewer ...

ByIntecna srl

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap