Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Downloads
  3. amperometric membraned sensor
Show results for
Products

Companies

Articles
Downloads

amperometric-membraned-sensor Downloads

9 downloads found

Cully - Model Halogen MP5-A i - Panel-Mount Multiparameter Water Quality Analyzer - Brochure

Cully - Model Halogen MP5-A i - Panel-Mount Multiparameter Water Quality Analyzer - Brochure

The Halogen MP5-A is a panel-mount multiparameter water quality analyzer designed for continuous, unattended operation in drinking water treatment and distribution networks. Using amperometric membrane sensor technology, it delivers accurate, stable free chlorine readings without the cost or complexity of reagent-based systems. Alongside free chlorine, the MP5-A simultaneously measures pH, ...
ByCully Automation Ltd.

Q45H/79 Total Chlorine Monitor - L-Q45H-79 Brochure

Q45H/79 Total Chlorine Monitor - L-Q45H-79 Brochure

ATI’s Model Q45H/79 TotalResidual Chlorine Monitor uses this same standardiodometric method, but with a membraned sensorfor measuring the iodine in solution. The systemtakes the reacted sample containing iodine and usesa membraned amperometric sensor rather thanexposed electrodes. The gas permeable membraneallows only iodine to ...
ByAnalytical Technology - a brand by Badger Meter

HaloSense - Chlorine Analyzers for Residual Chlorine Monitoring - Brochure

HaloSense - Chlorine Analyzers for Residual Chlorine Monitoring - Brochure

Free Chlorine and Total Chlorine analyzers and controllers measure the free residual chlorine (OCl– and HOCl), and the total residual chlorine (free chlorine + combined chloramines). The Pi residual chlorine analyzers are amperometric membraned sensors that bring a number of advantages over traditional colorimetric analyzers, in that they are cheaper to own with no reagants and very little ...
ByProcess Instruments (UK) Ltd. (Pi)

Q45H/85 - Peracetic Acid Monitor

Q45H/85 - Peracetic Acid Monitor

The Q45/85 Peracetic Acid Monitor uses a direct sensing polarographic probe mounted in a flowcell to measure PAA residuals in a flowing water stream. A permeable diffusion membrane isolates the sensing electrodes from the measured sample, providing long-term stability without electrode fouling problems. The measurement is selective for PAA, and is not affected by changes in ...
ByAnalytical Technology - a brand by Badger Meter

Data sheet KM 3000

Data sheet KM 3000

: 034327 623-0 Fax : 034327 623-79 Technical Specification KM 3000 Multi-Parameter Controller Power supply 115 / 230 V AC (-15/+10 %); 48…63 Hz, app. 25 VA (special version 24 V DC) Ambient temperature -10…+55 °C Display touch screen display 320x240 pixels, 256 colours, back-lighted Menu languages German, English Data transmission serial interface RS-232 and RS-485, GSM modem can be ...
ByXylem Analytics Germany Sales GmbH & Co. KG, Sensortechnik Meinsberg

Optical Design - Triton DO8 Optical Dissolved Oxygen Sensor Brochure

Optical Design - Triton DO8 Optical Dissolved Oxygen Sensor Brochure

The O2 values and diagnos2c values, including the aging of the sensor cap and any implausibly high or low oxygen values detected by the sensor are monitored by the Triton DO8 sensor and digitally communicated to the C-22 controller. ...
ByElectro-Chemical Devices (ECD)

Triton DO8 Optical Dissolved Oxygen Sensor Brochure

Triton DO8 Optical Dissolved Oxygen Sensor Brochure

lmson the sensor and provide a more representa2vemeasurement of the sample. Unlike amperometric dissolved oxygen sensors, thereare no membranes to replace, electrolytes to ...
ByElectro-Chemical Devices (ECD)

ASTI - Model 1056 - 4-Wire Single, Dual or Triple Channel pH/ORP/ ISE/Conductivity Analyzer & Transmitter -  Brochure

ASTI - Model 1056 - 4-Wire Single, Dual or Triple Channel pH/ORP/ ISE/Conductivity Analyzer & Transmitter - Brochure

TheModel 1056 displays dissolved oxygen in ppm, mg/L,ppb, µg/L, % saturation, % O2 in gas, ppm O2 in gas.The analyzer fully compensates oxygen readings forchanges in membrane permeability caused by tempera-ture changes. An atmospheric pressure sensor isincluded on all dissolved oxygen signal boards to allowautomatic atmospheric pressure determination at thetime ...
ByAdvanced Sensor Technologies, Inc. (ASTI)

ASTI - Model 56 - 4-Wire Transmitter, Controller & Analyzer - Brochure

ASTI - Model 56 - 4-Wire Transmitter, Controller & Analyzer - Brochure

Dual range calibration for chlorine sensors ? Programmable polarizing voltage for amperometric oxygen sensors ? ...
ByAdvanced Sensor Technologies, Inc. (ASTI)
  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT