FCI provides flow transmitters that include a thermowell mounted sensing element and integral or remote electronics that accurately indicate flow rate at the sensing location. The flow element is directly installed into piping or ducting on commercial and military aircraft, spacecraft, vehicles and marine applications. Please complete and submit the attached Application Data Sheet or contact ...
Premium
Ideal for low gas flow application: Gas flow sensor with decoupled heater and temperature elements with flow range from 0 to 100 m/s, -20 °C to +150 °C. Hotmelt housing dimensions and element resistances identical with FS7. Compatible with iST's Flow demo board. Detailed dimensions: Housing: Ø 6.0 (±0.1) mm, LH = 14 (±0.2) mm Sensor elements (outside hotmelt): 4.0 ...
Premium
Gas flow sensor with flow range from 0 to 100 m/s and temperature range from -20 °C to +400 °C. For measuring flow rates using a symmetrical heater design and having an excellent sensitivity and reproducibility. ...
Premium
OSI's patented Optical Flow Sensor (OFS) makes drift-free measurements across the entire stack, duct or pipe diameter and calculates an accurate average flow reading. It is the only flow sensor that gives a true non-contacting cross-stack flow measurement of the process. ...
Premium
OFS 2000 measures optical scintillation across the entire distance between the transmitter and receiver. It is the only flow sensor that gives a true non-contacting complete cross-stack flow measurement. OSI’s patented optical scintillation measurement algorithm uses advanced Digital Signal Processing (DSP) to measure the movement found in ...
Premium
Manufactured by Smart Storm in the UK, the Digison range of Ultrasonic Level Sensors and Ultrasonic Flow Sensors is renowned for high accuracy and low power consumption. Manufactured from HDPE, all sensors have internal electronics with integral temperature sensor to compensate for changes in ultrasonic velocity ...
Premium
Flow range from 0 to 1.5 m/s (full bridge mode), -20 °C to +80 °C, fast response time. MicroFlowSens technology for fast flow measurements. Thermal gas flow sensor with ultra low thermal mass resulting in high sensitivity and fast response time. ...
Premium
Microwave sensor for contactless monitoring of material flow and detection of material blockage. The system operates with no contact in a process in which the material movement is detected by using the Doppler effect. The FlowJam is a process-secure device, since the microwave technology used can penetrate material coating on the sensor and reliably detect the material movement behind it. If ...
ByENVEA
Premium
Gas flow sensor with flow range from 0 to 1.5 m/s (full bridge mode), temperature range from -20 °C to +80 °C, fast response time, mounted on a PCB for easy integration. MicroFlowSens technology for fast flow measurements. Thermal gas flow sensor with ultra low thermal mass resulting in high sensitivity and fast response time. ...
Premium
Gas flow sensor with flow range from 0 to 1.5 m/s (full bridge mode),temperature range from -20 °C to +80 °C, fast response time, mounted on a PCB for easy integration. MicroFlowSens technology for fast flow measurements. Thermal gas flow sensor with ultra low thermal mass resulting in high sensitivity and fast response time. ...
Premium
The FastFlo 620S is an insertion thermal mass air flow sensor designed to give you a highly reliable, responsive and affordable mass flow measurement for light industrial applications where a NEMA 4X (IP65) enclosure is acceptable. ...
Premium
This manual describes the MT100 PROFIBUS PA features, operation and configuration. The MT100 provides 3 different process variables that can drive an output: Flow, Temperature, and Flow Totalizer. The flow output can be selected as a volumetric flow, mass flow or velocity flow, depending on the MT100 configuration. The basic MT100 supports up to eight flow sensors and provides the average flow of ...
Premium
OSi's patented Optical Flow Sensor (OFS) makes drift-free measurements across the entire stack, duct or pipe diameter and calculates a true average flow reading. The OFS 2000-W model is equipped with Automatic Gain Control (AGC) to compensate for variations in opacity caused by particulate matter or moisture carried in the stack ...
Premium
Ultrasonic sensors for flow measurement with very high accuracy in slight to heavily polluted media. ...
Premium
OSi's patented Optical Flow Sensor (OFS) makes drift-free measurements across the entire stack, duct or pipe diameter and calculates an accurate average flow reading. It is the only flow sensor that gives a true non-contacting cross-stack flow measurement of the process. The OFS uses our EPA Method 14 approved optical scintillation technology. The optical scintillation technique relies on ...
Premium
OOFFSS--22000000CCTTMM CCoommbbuussttiioonn AAiirr FFllooww OFS-2000CTM Advantages • Optimized for Primary and Secondary combustion air • Temperature and pressure corrected flow or mass flow output (includes RTD temperature probe) • Cross stack/duct/pipe line measurement for more accurate flow readings. • Non-interfering; nothing in ...
Premium
370 sets new standards of safety, guarantees accurate measurement results, and for the first time, offers an upgrade option to include an autosampler.Advantages Rapid installation on standard lab desks Automatic emptying of sample tube and receiving vessel after distillation and determination Compact stand-alone unit with modern, functional design Leading-edge, high-performance multitasking ...
ByBUCHI
Premium
OFS-TEST-N2 NIST Wind Tunnel Test Calibration Date: April 19-24, 2001 1 REPORT OF SPECIAL TEST Of Optical Flow Sensor (OFS) At National Institute of Standards and Technology (NIST) April 2001 Optical Scientific, Inc. 205 Perry Parkway Gaithersburg, MD 20877 REPORT OF OFS TEST AND CALIBRATION Optical Scientific, Inc. OFS-TEST-N2 NIST ...