Premium
Monitors dissolved chlorides and potassium in groundwater, continuously and automatically. Replaces or supplements periodic groundwater sampling — delivering real-time data on plume stability and remediation performance without repeated field visits. Real time sensor data routinely updates groundwater models for improved risk assessment. ...
ByLiORA
Premium
Monitors dissolved petroleum hydrocarbons and gases in groundwater, continuously and automatically. Replaces or supplements periodic groundwater sampling — delivering real-time data on plume stability and remediation performance without repeated field visits. Real time sensor data routinely updates groundwater models for improved risk assessment. ...
ByLiORA
Premium
Continuous, autonomous in-well sensor for dissolved chloride in groundwater. Replaces or supplements periodic manual sampling, delivering daily data for plume tracking, remediation performance, and groundwater-model updates without repeated field ...
ByLiORA
Portable, electric groundwater sampling ...
These pumpsrepresent the ultimate device for recovering representative groundwater samples to depths of 250’(77 m) without compromising the chemical integrity of the samples. ...
The use of disposable filters: Filtration of groundwater under anaerobe conditions and directly on site is necessary to prepare groundwater samples for later analysis in the lab on (trace) metals. Soil particles (> 0.45 μm) must be removed from the ...
Low-flow purging and sampling (astm standard d67771) is a well-known method of extracting groundwater samples from a well at a very low rate (less than 500 ml/min) in order to minimize contaminant volatilization and the amount of wastewater generated. The in-situ low-flow sampling system and vusitu™ mobile app saves you ...
CityChlor: Validation of EnISSASite description: This report presents the results of the EnISSA MIP-measurements and their comparison with traditional sampling methods within the CityChlor pilot site in the city of Kortrijk, Belgium. The systematic validation of the EnISSA MIP is based on traditional soil samples and groundwater ...
DEDICATED DEDICATED DEDICATED DEDICATED GROUNDWATER SAMPLING PUMP SYSTEM __________________________________ DESCRIPTION Fultz Pumps, Inc.’s dedicated pump system provides for one of the most user friendly installations in the industry. ...
PORTABLE PORTABLE PORTABLE PORTABLE GROUNDWATER SAMPLING PUMP SYSTEM __________________________________ DESCRIPTION Our dedicated freestanding portable pump system is ideal for short term monitoring projects. ...
The Grundfos MP 1 is a 2” environmental pump used for water monitoring. You can collect groundwater samples for analysis from depths down to 90 m to establish the precise type and degree of contamination. The Grundfos MP 1 submersible pump is specially designed for purging and sampling of monitoring wells with a diameter of at least 50 mm ...
QED’s new Power Pro ESPTM low-flow electric sampling pump (patent pending) has an all-in-one design with userfriendly controls built into the reel. You won’t need a heavy AC generator – just run the Power Pro off your vehicle’s battery, or go mobile in the field using a portable 12 VDC battery. The ESP Communications ProtocolSM provides simple pump operation with ...
The Power Pro ESP™ portable electric sampling pump was developed exclusively for low-flow ground water sampling. The heart of the pump is a variable speed, brushless motor combined with a high-efficiency impeller. This unique combination consumes 50-75% less power (based on manufacturers’ published specs), which translates to user benefits of less heat, lighter and more flexible power ...
DISPOSABLE TUBING DISPOSABLE TUBING DISPOSABLE TUBING DISPOSABLE TUBING GROUNDWATER SAMPLING PUMP SYSTEM __________________________________ DESCRIPTION Our portable disposable tubing sampling pump system is designed for reliable and efficient purging and sampling of monitoring wells. ...
Premium
The SingleSample High Capacity Groundwater Capsule (HCGW) is used to filter groundwater sample taken for metals ...
BAT is a registered trademark of BAT Geosystems AB. BAT Groundwater Monitoring System BAT Geosystems AB Phone: +46851170600 P.O. ...
Down well or above ground, QED opens up new possibilities by adding a new high-temperature polymer tubing to the lineup of Nitrile hose and jacketed nylon tubing sets for airpowered pumps. With a maximum working temperature of 250° F (121° C) at 100 PSI, Red-Line Tubing will be a problemsolver at your most challenging job sites. High-temperature tubing sets have the same UV protection as ...
Well Wizard Bladder Pumps: The Original, Low-Flow Sampling Standard. Well Wizard pumps for MicroPurge low-flow groundwater sampling systems come in an unsurpassed range of sizes, materials, and capabilities, including models for deep sampling wells, narrow or obstructed casings, and small-volume pumps for low-yield monitoring wells. Together with MicroPurge controllers, flow cells, and ...
The Sample Pro XD Portable Pump is the first pump developed specifically to bring the advantages of low-flow sampling to sites requiring portable pumps. Pneumatic design can be operated with compressed air or compressed gas cylinder for complete ...
Monitoring Choices—The Snap Sampler The Snap Sampler is a proven and regulatory-accepted passive groundwater sampling approach that seals groundwater samples in situ, and eliminates most of the effort required to collect samples. ...