micro-electrode Downloads
15 downloads found
Premium
µStat 4000 with a size of only 22x20x7 cm, includes 4 channels that can act at the same time as 4 independent potentiostats/galvanostats; it also includes one multichannel that can act as a potentiostat where up to 4 working electrodes share an auxiliary and a reference electrode. With µStat 4000 users can perform up to 4 different electrochemical techniques at the same time; or carry ...
Premium
With a size of only 22x20x7 cm, µStat 8000 is an equipment that includes 8 channels that can act at the same time as 8 independent potentiostats/galvanostats; it also includes one multichannel that can act as a potentiostat where up to 8 working electrodes share an auxiliary and a reference electrode. With µStat 8000 users can perform up to 8 different electrochemical techniques at ...
The pHMaster BIO is designed with biological and life science applications in mind and is packaged with a combination electrode specific for TRIS buffer preparation thus overcoming the issues of inaccuracy obtained with general pH probes. There is also an optional micro pH electrode with a 4.5mm diameter for small volume applications in 1.5/2ml ...
15 pairs interdigitated gold electrodes (10/10 µm, electrode/gap) integrated into a 40-µm height SU8 microchannel. Useful for FIA systems enhancing the sensitivity. Compatible with AIO and Multi8x AIO cell with TL add-ons. ...
DescriptionTL 7500 KF 05 285220810Volumetric KF-Titrator, scope of supply: titrator unit, interchangeable module WA 05, TM 235 KF titration stand with integrated stirrer and pump, titration vessel TZ 1770, micro-dual platinum electrode KF 1100 and starter kit, power supply 100-240 VTL 7500 KF 10 285220820Volumetric KF-Titrator, scope of supply: titrator unit, ...
DescriptionTL 7500 KF 05 285220810Volumetric KF-Titrator, scope of supply: titrator unit, interchangeable module WA 05, TM 235 KF titration stand with integrated stirrer and pump, titration vessel TZ 1770, micro-dual platinum electrode KF 1100 and starter kit, power supply 100-240 VTL 7500 KF 10 285220820Volumetric KF-Titrator, scope of supply: titrator unit, ...
Amperometric Designo Externally polarized by the C22o Gold Cathodeo Silver-Silver Halide Anode316 SS Counter Electrodeo 316 SS Counter Electrode? Replaceable Micro Porous Teflon Membrane? Refillable Potassium Iodide Gel Electrolyte? ...
RE: reference electrode. AE: auxiliary electrode. Electrodes are available in different designs and materials: *Customized designs of microfluidic chips and electrodes are available on demand. ...
HORIBA GmbHKaplanstrasse 5A-3430 Tulln, AustriaPhone: 43 (2272) 65225Fax: 43 (2272) 65230HORIBA CZECHIAOrganizachi slozka PrahaPetrohradska 13CZ-101 00 Praha 10, Czech RepublicPhone: 420 (2) 717-464-80Fax: 420 (2) 717-470-64HORIBA SWEDENHertig Carlsv¨ag 55-57S-15138 So¨derta¨ljeSwedenPhone: 46 (8) 550-80701Fax: 46 (8) 550-80567HORIBA ITALYEuropalaceCorso Torino 43/4510043 ...
Alterna-tively, you can use a rod stirrer which enables stirring from “above”.128Washing the electrode and the titration tip To ensure accuracy of the results, the electrodes and the titration tips are rinsed after each titration. ...
Flushing Junction Electrodes 10................................................................... ...
Technical data: Ion concentration mode Calibration automatic, 1-/2-/3-/4-/5 points Concentration units ppm, mg/L, M, % pH mode Calibration automatic, 1, 2 or 3 points, automatic buffer recognition Measuring range -2.000 … 19.000 pH Resolution 0.001/ 0.01 pH Accuracy ± 0.005 pH ± 1 digit mV mode ...
Powered by bench top meters of series HD22… with cable HD22.2.1 (optional) or supplier SWD10 (optional)HD22.3: Laboratory electrode holder with metal basis plate. Flexible electrode holder for free positioning. ...
By cropping the sensor, one achieves faster frame and spectral rates because the temporal resolution will be dictated only by the time it requires to read out the small section of the sensor.312T 320T 334T 340TSensor array size 512 x 512 1024 x 255 1024 x 1024 2048 x 512Pixel size 24 x 24 µm 26 x 26 µm 13 x 13 µm 13.5 x 13.5 µmMax. readout speed 5 MHz 5 MHz 5 MHz 3 MHzCrop mode rates (imaging) ...