Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Downloads
  3. pcdds
Show results for
Products
Services
Software
Applications

Companies

News
Articles
Books
Downloads
Videos

pcdds Downloads

25 downloads found

Envea - Model Amesa-M - Mercury Sorbent Trap System - Brochure
Premium

Envea - Model Amesa-M - Mercury Sorbent Trap System - Brochure

More than 20 years experiences of continuous sampling of Dioxins and Furans (PCDD/PCDF) with the AMESA system, MCERTs & TÜV certified, were used to design the AMESA M for continuous sampling of ...
ByENVEA

Envea - Model Amesa-D - Permanent Dioxins and Furans Sampler - Brochure
Premium

Envea - Model Amesa-D - Permanent Dioxins and Furans Sampler - Brochure

TÜV and MCERTs certified, ETV EPA approved The AMESA-D utilizes the water cooled probe method with Isokinetic sampling system coupled with XAD-II adsorbent cartridge for Long-term sampling of dioxins (PCDD), furans (PCDF) and other persistent organic pollutants ...
ByENVEA

TCR Tecora - Model MCS2 - Isokinetic Heated Probe for PCDD/F - Datasheet

TCR Tecora - Model MCS2 - Isokinetic Heated Probe for PCDD/F - Datasheet

Condensing and adsorbing device MCS2 for the determination of PCDD/PCDF in compliance to EN 1948 Method. The EN 1948-1 “Filter condenser” method foresee the isokinetic sampling with a heated probe, filterholder and adsorbing trap XAD2/PUF after the ...
ByTCR-Tecora

TCR Tecora - Model USEPA MCS2 - Condensing and Adsorbing Device - Datasheet

TCR Tecora - Model USEPA MCS2 - Condensing and Adsorbing Device - Datasheet

Condensing and Adsorbing Device EPAMCS2 for the Determination of PCDD/PCDF in Compliance to EPA 23 and EN 1948 Method. The EPA 23 and EN 1948-1 methods foresee the isokinetic sampling line with a heated probe, filterholder and XAD2 adsorbing trap for both gas and ...
ByTCR-Tecora

Dioxin & PCB Analysis Brochure

Dioxin & PCB Analysis Brochure

Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs. Sampling of PCDDs.PCDFsStationary source emissions. Determination of the mass concentration of PCDDs/PCDFs and dioxin-like PCBs. Extraction and clean-upStationary source emissions. ...
BySigma-Aldrich

ISOFROST 3 Closed Circuit Portable Chiller - Datasheet

ISOFROST 3 Closed Circuit Portable Chiller - Datasheet

ISOFROST 3 was born from the development of previous chiller systems ISOFROST and ISOFROST 2. ISOFROST 3 is able to support multiple samplings in extreme environmental conditions (e.g. summer season). A magnetic drive recirculation pump is incorporated in the device and not takes up valuable space in the tub allowing simultaneous sampling of PCDD/F & PCBs and others (e.g heavy metals, ...
ByTCR-Tecora

Minsorb - Mineral Alternative For The Removal of Micro-Pollutants Brochure

Minsorb - Mineral Alternative For The Removal of Micro-Pollutants Brochure

ue gas treatmentMinsorb® is a family of 100% mineral reagents dedicated to the removal of micropollutants:• dioxins/furans (PCDD/PCDF), PCB and PAH• mercury: metallic and ionicEuropean sourced raw materials designed for ? ...
ByLhoist Group

DARCO - Model FGD - Powdered Activated Carbon - Brochure

DARCO - Model FGD - Powdered Activated Carbon - Brochure

It has been proven in numerous full scale operating facilities to be highly effective for the removal of gaseous mercury, dioxins (PCDD) and furans (PCDF). Its open pore structure and fine particle size permit rapid adsorption, which is critical for high performance in flue gas streams where contact times are short.DARCO FGD is a free flowing powdered carbon with minimal caking ...
ByJ Carpenter Environmental LLC (JCE)

TCR Tecora DECS Fixed System for Dioxins Sampling on Stack Emissions - Datasheet

TCR Tecora DECS Fixed System for Dioxins Sampling on Stack Emissions - Datasheet

DECS is an automatic sampling system, realized for permanent installation on stacks, dedicated to “long terms” Dioxins and Furans collection (PCDD/PCDF) and other ...
ByTCR-Tecora

Tecora - Model DECS - Continuous Emission Dioxins Sampler Brochure

Tecora - Model DECS - Continuous Emission Dioxins Sampler Brochure

DECS is the solution offered by CDL-Tecora for the continuous emission sampling of Dioxins, Furans (PCDD/PCDF),PCB and other POPs. According to EN 1948 and USEPA M23 standard, DECS adopts the filter/condenser method with adsorbing trap on wet gas. The system is permanently installed on stack for continuous sampling from 6 hours up to 6 ...
ByTecora

Company Brochure

Company Brochure

PM10, Dust 30 min – 120 min ? PCDD/F 1 hour – 8 hours ? Metals 30 min - 24 hours Sampling in ambient air ? PM10, dust 24 hours ? PCDD/F up to 48 hours ? Metals up to 48 hours Range of application Sampling volume Flue gas velocity Humidity in stack Ambient humidity Acid sack gases ? ...
ByGenius5-Instruments GmbH

TCR Tecora ECHO EMERGENCY HV High Volume Sampler + Real Time PM - Datasheet

TCR Tecora ECHO EMERGENCY HV High Volume Sampler + Real Time PM - Datasheet

ECHO EMERGENCYHV is the new TCR Tecora® high volume sampler for particulate and micropollutants sampling and monitoring in extreme conditions. TCR Tecora® research division highlighted the need to design a sampling system that can offer a viable solution in emergency or remote situations such as fires, high mountain, isolated areas, contaminated environments to allow PTS/PM10/PM2,5/PM1 ...
ByTCR-Tecora

Range of Products Essential Component Parts Brochure

Range of Products Essential Component Parts Brochure

E dry or semi-dry chemisorption of acid crude gases such as HF, HCl, SOx, B2O3 with Ca- or Na-based additive powders?? E adsorption of PCDD / PCDF, as well as Hg and Hg-compounds, by means of activated coal / -coke or other additive qualities with large inner surfaces?? ...
ByLuehr Filter GmbH

Sorption Processes Brochure

Sorption Processes Brochure

E dry or semi-dry chemisorption of acid crude gases such as HF, HCl, SOx, B2O3 with Ca- or Na-based additive powders?? E adsorption of PCDD / PCDF, as well as Hg and Hg-compounds, by means of activated coal / -coke or other additive qualities with large inner surfaces?? ...
ByLuehr Filter GmbH

Luehr Filter GmbH Co-KG Company Brochure

Luehr Filter GmbH Co-KG Company Brochure

E dry or semi-dry chemisorption of crude gases such as HF, HCl, SOX?? E adsorption e.g. of PCDD / PCDF and heavy metals such as Hgif necessary with integration of measures for heat recovery.OUR CORE ACTIVITY ISthe forward-looking and innovative development of our products and procedures for the separation of particulate and gaseous substances from the air and / or process ...
ByLuehr Filter GmbH

Air Pollution Control Brochure

Air Pollution Control Brochure

E dry or semi-dry chemisorption of crude gases such as HF, HCl, SOX?? E adsorption e.g. of PCDD / PCDF and heavy metals such as Hgif necessary with integration of measures for heat recovery.OUR CORE ACTIVITY ISthe forward-looking and innovative development of our products and procedures for the separation of particulate and gaseous substances from the air and / or process ...
ByLuehr Filter GmbH

Flyer Exzess N2 Brochure

Flyer Exzess N2 Brochure

This includes priority substances according to the European Water Framework Directive (EU-WFD), as well as pesticides and their metabolites, pharma-ceuticals and their metabolites, perfluorinated tensides (PFTs), brominated flame retardants, poly-chlorinated dibenzodioxins/dibenzofurans (PCDD/DF), and many more. In addition to groundwater, drinking water, surface water, and ...
ByGesellschaft für Bioanalytik Hamburg mbH(GBA)

Simatek - Pneumatic Conveying System  - Brochure

Simatek - Pneumatic Conveying System - Brochure

Typical Emission Values Flue Gas Inlet Concentrations EU-Directive or 17 BimSchV Achieved Emissions HCl 1.500 mg/Nm3 10 mg/Nm3 <5 mg/Nm3 SO2 800 mg/Nm3 50 mg/Nm3 <10 mg/Nm3 HF 100 mg/Nm3 1 mg/Nm3 <1 mg/Nm3 PCDD/F TEQ 10 ng/Nm3 0.1 ng/Nm3 <0.035 ng/Nm3 Hg 5 mg/Nm3 0.05 mg/Nm3 <0.005 mg/Nm3 Other heavy metals 200 mg/Nm3 0.5 mg/Nm3 0.005 mg/Nm3 Dry Sorption Concept ...
BySimatek A/S

Company Profile Brochure

Company Profile Brochure

13211:2001 ???s ISO 11338-1:2003 PCDDs/PCDFs/PCBs ?? 1948-1:2006 Water vapour / Moisture EN 14790: 2005 Velocity and volume flowrate ISO 10780:1994 TOC EN 12619:1999 EN 13526:2002 ...
ByEnvirometrics Ltd

Instructions for the Supelco Dioxin Prep System: Multi-Layer Silica Gel Column and Dual-Layer Carbon Reversible Column

Instructions for the Supelco Dioxin Prep System: Multi-Layer Silica Gel Column and Dual-Layer Carbon Reversible Column

No. 28408-U) (Figure 2) are avail-able to perform this conditioning quickly and more effectively.The flow after vacuum assisted conditioning will be about 3mL/min.The column is then ready to accept an n-hexane extract of thesample. The analytes (coplanar PCB/PCDD/PCDFs) in theextract will pass through the column with minimal retentionwhile interferences and carry-over ...
BySigma-Aldrich
  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT