pulse-counter Downloads
83 downloads found
ESMB DI is a compact data readout and transmission controller, which has digital inputs. The controller is used for pulse counting or data collection of various sensors (eg. Optical) and measuring instruments (eg. temperature, pressure). ESMB DI transmits data via 20 mA current loop or RS485 communication interface using Modbus protocol. One of the main advantages of ESMB DI – profiling ...
ESMB DI is a compact data readout and transmission controller, which has digital inputs. The controller is used for pulse counting or data collection of various sensors (eg. Optical) and measuring instruments (eg. temperature, pressure). ESMB DI transmits data via 20 mA current loop or RS485 communication interface using Modbus protocol. One of the main advantages of ESMB DI – profiling ...
Our 3rd generation low-power cellular pulse counter and data logger with a built-in cellular modem for smart water and gas metering. ...
120120RoHSAC/DC12...250 V 30 Hz - 10° + 50° IP65 DIN 48 x 48000000 1 2 3 4 50 0 0 0 00000006 LCDswww.kuebler.com © Fritz Kübler GmbH, subject to errors and changes. 10/2013 Order-No. LCD preset counter 6.901.010.800 1)Delivery specification- Counter 901- 2 lithium batteries- 1 screw terminal- 1 spring clip- 1 operating instructions- 1 front bezel for screw ...
Digital event inputs may be programmed as pulse counters. Analog Event Mode - A change in the reading of an analog channel generates a report for earlier detection of rapidly changing conditions. ...
Accumulator Digital inputs may be programmed as pulse counters. Control Output - (optional) 4 maximum 0.1A current sink per control output, 12 V supply available internally to drive load. ...
The DIN-32 Module is a versatile pulse counter and datalogger with 32 discrete input channels, fully compliant with Modbus TCP and Modbus RTU protocols. It provides real-time data acquisition with each record timestamped using an integrated Real-Time Clock (RTC). Designed for industrial applications, the DIN-32 offers robust communication options and seamless integration with both Advanticsys ...
BEAM-VW-S1 Supports 1 sensor (1 vibrating wire channel, 1 pulse counter, and 1 thermistor channel). BEAM-VW-S8 Supports 8 sensors (8 vibrating wire channels and 8 thermistor ...
ByAckcio
Analogue electromagnetic dosing pump with constant, manually adjustable and proportional dosing by digital signal (e.g. pulse counter). ...
Environmental Measuring Systems Turistická 5, 621 00 BRNO, Czech Republic, phone/fax +420 541 225 344 Main features: •••• low cost •••• compact size •••• low current consumption •••• particularly attended for temperature measurement with thermocouples •••• programmable external switch •••• Manufactured by EMS www.emsbrno.cz Specification: •••• eight voltage inputs in eight ranges up ...
The H2O Degree WM-1000C Cold Water Meter is a flexible axis pulse equipped cold water meter that is compatible with the H2O Degree wireless pulse counter. These quiet and accurate meters fit inside challenging installation locations including between studs, under counters, along pipes and against walls. Regardless of pipe angle, the meters are designed so that the measuring chamber can always be ...
//APPLICATIONS// main featuresBeanDevice® ONE-BN main presentation videofeatured video2-channel digital inputs with noise filtering (software configurable)Watertight IP67 polycarbonate enclosureWeight : 120g, Size (Lxlxh) : 119x35x35mmPrimary cell capacity: 1800 mAh (AA size)Lithium-thionyl chloride technologyWireless PULSE data logger / low cost & small size//Wireless ...
Counter head 1.7.2. NF-Reed-Contacts 1.7.3. NF-NAMUR-Pulse sensors 1.7.4. ...
Aranet Radiation sensor ensures comprehensive ionizing radiation monitoring by measuring both the total dose and dose rate, with an optional instant audial ionizing radiation detection feature (pulse counter ...
Count totals, frequency, periods, pulse widths and elapsed time.? Switch digital channels on alarms? Save data as text, xml, Energy Lens compatible or in aMySQL ...
This damage could cause leaks or failure of the meter.6/ When installing the reed switch (pulsed output wire), the distance from the meter to the control unit/pulse counter is best kept under 20 metres as voltage will drop. The reed switches are normally open, volt free, but operate on the 0-24v DC range when the pulse is made. A ...
Logbooks with more than 200 entries each ? Peak shaving ? 4 pulse counters (e.g. kWh counter) ? communication to www DATA SHEET DELOMATIC 4, DM-4 HYDRO Data sheet DM-4 Hydro DEIF A/S Page 2 of 8 Hardware The DM-4 Hydro delivery from DEIF consists of: - DM-4 Hydro 19” rack - 12” touch screen PC Application The ...
ByDEIF A/S
A specific timing is possible through anexternal signal (totalizer counter with pulse output, external contact). TECHNICAL FEATURES Dimensions: Wall mounting housing, 120 x 80 x 55 mm (Overall system 250 x 220 x 100 mm)Ambient temperature: +5...+50°C% R. ...
Ordering code Model Interface Interface Interface Interface RTC Pulse 702 . 023 . A B C D . E . F 0 – None 1 – RS485 2 – RS232 0 – None 1 – RS232 2 – M-Bus 3 – Data/Req 0 – None 1 – RS232 0 – None 1 – Current loop 0 – None 1 – Real Time Clock (RTC) 2 – Real Time Clock + 32Kb EERAM 0 – None 1 – Pulse ...
Digital inputs 4 inputs, closing contact or logic level (nominal 5V, HCMOS compatible with protection for over-voltage up to +15V). Pulse counter inputs Digital inputs may be independently programmed as pulse counters Digital outputs 4 outputs, open collector to 0V, 20V @ 200mA (500mA peak) rated Analogue inputs 4 inputs, 0 to ...