sampling-valve Downloads
325 downloads found
Premium
The GO-FLO sampling bottle feature a close-open-close operation. Opens automatically (hydrostatic pressure activated) at approximately 10 meters (33 feet), then flushes until closed by standard GO Devil messenger (model 1000-MG) individually, serially, or sequentially by remote command with a model 1018 or 1015 Rosette multi-bottle array. Inert gas can be injected into bottle to ...
Premium
The GO-FLO sampling bottle feature a close-open-close operation. Opens automatically (hydrostatic pressure activated) at approximately 10 meters (33 feet), then flushes until closed by standard GO Devil messenger (model 1000-MG) individually, serially, or sequentially by remote command with a model 1015 Rosette® multibottle array, or with model AR1015 Acoustic Command ...
Premium
A valve extension cable is available to allow the selection valve(s) to be placed at the sampling point, eliminating the need to run two separate lines to the instrument. For more complex switching applications, multiple 3-way valve units may be connected to switch in tandem with the first valve. This ...
Premium
The GO-FLO sampling bottle feature a close-open-close operation. Opens automatically (hydrostatic pressure activated) at approximately 10 meters (33 feet), then flushes until closed by standard GO Devil messenger (model 1000-MG) individually, serially, or sequentially by remote command with a model 1018 or 1015 Rosette multi-bottle array. Inert gas can be injected into bottle to force retrieved ...
Strahman Drain Valves 3" NB through 12" NB ANSI classes 150, 300,and 600 and 2" NB ANSI classes 300 and 600 comply under Category II liquid service.2Quik™ Sampling ValveThe innovative Quik Sampling Valve (QSV-700) was designedspecifically for industrial applications that require precise sam-pling control and operator safety. ...
Tight-closing cavity-free inline valve designed to sample liquids from flowing media without bypass. Particularly suitable for aggressive media in process plants: Nominal diameters DN 25 to DN 100, nominal pressure PN 10/16 and PN 40, temperatures -20°C to ...
For safe and representative sampling of corrosive, aggressive or even toxic media from pipelines, pressurized or at vacuum conditions – without process interruptions. Sampling Valves ISV Series are available as DIN or ANSI valves, with handwheel as per standard. The valves are distinguished by its dead-space-free design as well as the extremely short outlet way for the representative ...
316L SS construction machined to less than 20 Ra. ...
Premium
Gas analyzers for emissions measurement are often exposed to heavy soot and dust contamination. Therefore it is necessary to filter the sample gas stream. The J.U.M. Engineering PreFilter is an efficient, all heated and low pressure drop sample interface for removing solids from two gaseous sample streams. The Model VE 222 utilizes two independent all stainless steel 2pm mesh filters and two ...
The AKTA pure is however currently limited to a maximum of 14 (2 sample inlet valves, no limit on volume), 24 (10ml samples with Alias autosampler) or 192 (2mL samples with Alias autosampler) samples being analysed per run. ...
Premium
It is built with a heated multiposition valve. The temperature of the valve and of the sampling line can be set at up to 100°C (or more) to decrease the risks of condensation and to decrease the possibility to lose some molecules during the sampling phase (e.g. heavy hydrocarbons, phenol ...
The unit will measure continuously from an off-gas vent or periodically via a gas sample valve to take small 10-15ml samples from the bioreactor headspace via keypad or digital interface ...
316L SS construction machined to less than 20 Ra. Pressure Rating: 300 PSI at 200°F. ...
BASIC KIT DELUXE KIT ULTIMATE KIT BASE KIT Z-Lite IAQ Pump (Includes Integrated combination fl ow meter/regulator valve) Tubing Sampling Stand Bioisolation Filter Toolbox Style Carrying Case Instructional CD-ROM Z-Lite IAQ Pump (Includes Integrated combination fl ow meter/regulator valve) Tubing Sampling Stand Bioisolation ...
A third source of high counts is the sampling procedure itself if the sample line is not flushed adequately, if the sample valve is touched at the wrong time or if contaminated sample bottles are used. ...
In the event of a chemical leak within the chemical particle counter or sample connections, the system will automatically detect the leak, shut off inlet and outlet sample valves, turn off power to the particle sensor, and provide an external alarm ...
