weir-flow Downloads
84 downloads found
All flow control weir shall be produced from fiberglass reinforced isothalic polyester resins. Weirs may be v-notched, square notched, straight flat edge, or straight beveled edge. V-Notch weirs shall have evenly spaced notches throughout the length of the weir except at the splice ...
skim-pak ®11800-DH Floating Decanter370 GPM / 1.4 m3PM CapacityFlow - Control and Floating Decanter SystemsThe 11800-DH has flow-controlled weirs with adjustable flow rate capabilities. The standard flow rate is 3 cubic meters per minute per meter of weir. The 11800-DH has 0.5 meters of total ...
BySkim-pak
skim-pak ®11820-DH Floating Decanter1580 gal/min / 6 m3min CapacityFlow - Control and Floating Decanter SystemsThe 11820-DH has flow-controlled weirs with adjustable flow rate capabilities. The standard flow rate is 3 cubic meters per minute per meter of weir. The 11820-DH has 2 meters of total ...
BySkim-pak
The perforated plate creates a physical barrier in the path of the flow, retaining gross solids of and above 6mm diameter in 2 dimensions.Operating PrincipleThe Cross Wave Copacurve™ is typically installed horizontally at 90 degrees to the overflow weir, with upward flow through the screen. ...
skim-pak®17500-SH Grinder skimmer90 GPM / 0.3 m3PM CapacityFlow - Control Grinder skimmer.The 17500-SH has flow-controlled weirs with adjustable flow rate capabilities. The flow control weir will automatically adjust to the flow rate being pumped. ...
BySkim-pak
An internal baffle creates an overflow weir, directing flows onto the internal vanes. The vanes are attached to the aperture drum and cause the drum to rotate. The internal baffle extends from the 3 o’clock position to the 12 o’clock position. This only allows flows to enter the drum when water levels are above the 3 o’clock weir ...
VOLUMETRIC WEIRS For measuring flows in Manholes and Open End Pipes WEIR SET 15” WEIR WITH 18” ADAPTER WEIR WITH BUBBLER TUBE (refer to back page for details) The most practical, economical instrument for testing new sewer lines - night ...
skim-pak®11840-DH Floating Decanter2958 gal/min / 11.2 m3min CapacityFlow - Control and Floating Decanter SystemsThe 11840-DH has flow-controlled weirs with adjustable flow rate capabilities. The standard flow rate is 3 cubic meters per minute per meter of weir. The 11840-DH has 4 meters of total ...
BySkim-pak
Vertically and radially floating baffle for use on fixed weir crests and open flow cross-sections to prevent the discharge of floating ...
Vertically floating baffle for use on fixed weir crests and open flow cross-sections to prevent the discharge of floating ...
Each unit is equipped with an internal data loggerthat provides for on-screen display of maximum, minimum and average daily flows. More than 70 standardflow equations for flumes, weirs and open flow nozzles are stored in non-volatile memory. ...
Enhanced Gravity Separation in aCompact ConfigurationHOW IT WORKS Particle settling is accelerated by tangential flow patternforces in a highly circuitous path. Through the use of two independent cylindrical separators and control weirs, low flow is initially directed to the first separator while moderate flow overflows the first ...
skim-pak®8500-SA Smart skimmer100% oil recovery with no layer left on surface.SMART SKIMMER, oil processorThe 8500-SH has a flow-controlled weir with adjustable flow rate capabilities. The skimmer will pull oil and water into the skimmer sump. ...
BySkim-pak
The most common arrangement is the “Flow Control Weir” Flow Control Weir Skim-Pak Flow Control Weir models clean oils, foams and other floating materials from water surface. ...
SGS AquaGate Float for water level control and optimum utilization of the available storage volume! Float-controlled weir gates have been used for more than 30 years to maintain the water level and to make optimal use of the existing storage volume at water overflows of any kind. SGS Aqua Technologies GmbH builds float-controlled weir gates for volume flows of up to 30 m3 /s. The dimensions of ...
The OCF 6.1 uses a non-contacting, ultrasonic sensor mounted over a flume or weir to measure flow, or inside / above a tank to measure level. It is accurate, reliable, and verifiable. The separate, watertight electronics / display enclosure can be mounted within 152.4 m (500 ft) of the sensor. The OCF 6.1 continuously displays, totalizes, transmits, and data logs open channel flow or ...
The Open Channel Flow 6.1 uses a non-contacting ultrasonic sensor mounted over a flume or weir to measure flow, or inside / above a tank to measure level. It is accurate, reliable, and verifiable. The OCF 6.1 continuously displays, totalizes, transmits, and data logs open channel flow or ...
It is compact and provides high throughput.There are headbox options, including deep flat and shallow tapered designs to accommodate solids loading. A swinging baffle across the weir directs the flow for the most efficient screen operation.The Hydroscreen unit’s unique bi-wave wedgewire screen panel, with double downward curves, increases the Coanda effect by ...
The RSPS then col-lects the oil under weir flow conditions. When the RSPS’s slots are rotated backward, the skimming temporarily ceases. ...
This process greatly reduces the amount of “free” or non emulsified water in the recovered oil, and more importantly, pumping from the recovered oil layer occurs independent of skimming different from other skimmers that utilize over flow weirs, adhesive belts, absorbent belts, absorbent ropes, rotating drums and discs, or Archimedes screws. ...