The D-Cant range of clarified liquid decanters typically consist of a submerged bellmouth or rectangular weir that is supported by floats and discharges via a flexible pipe. The weir is designed and installed to remove clarified liquid from the surface of a tank or basin without disturbing deeper layers where solids may be concentrated. ...
The converter is adaptable for many kinds and types of weirs and open channels. The built-in ISO 1438 formulas for flow calculations are preprogrammed with the most common flumes and weirs such as Parshall, Venturi, Palmer-Bowles flumes and V-notch and rectangular weirs. Also to be used with non-standard channels and ...
Hydro Gate® overshot gates are overflow-style adjustable weirs that features a rectangular steel panel hinged at the bottom. The steel panel is raised and lowered using cables attached to the upper corners of the gate. Upstream water levels are controlled by raising or lowering the gate, which can be operated manually or electrically. ...
ApplicationDescriptionThe PGS 300F controller is deployed together with one or twosensors capable of supplying standard 0 or 4-20 mA currentsignals (e.g. submersible transmitters ETG) to offer aversatile, intelligent decentralised control solution designedfor use in all areas of water management where in addition toeasy operation and high levels of operational reliability precisedetermination of ...
They are microprocessor controlled and will monitor liquid flow through any flume or weir. Applications range from monitoring flow rates in sewage works to industrial waste discharges.Precise flow depth measurements are continuously made under processor control. ...
Round Select Round for open pipes and enter the pipe ID (Inside Diameter). Square Select Square for rectangular channels and enter the width of the channel. Egg Select Egg for channels with cross-section dimensioned as shown. ...
Use the versatility of HydroMace XCi to monitor inputs as diverse as: Flumes & weirs, water quality sensors & rainfall gauges, drinking water flows (leak detection) and weather stations. ...
ByMACE
VOLUMETRIC WEIRS For measuring flows in Manholes and Open End Pipes WEIR SET 15” WEIR WITH 18” ADAPTER WEIR WITH BUBBLER TUBE (refer to back page for details) The most practical, economical instrument for testing new sewer lines - night flow studies of existing lines – ...
The large display can be viewed easily from a distance or when process lighting conditions are dim.The USonic-R is preprogrammed with common tank shapes and Open Channel Flume and Weir characterizations. The menu driven software additionally offers a 21-point strapping table for non-linear inputs in level, volume or open channel flumes and weirs. 2-Channel ...
Rectangular suppressed sharp crested weir ? Rectangular contracted sharp crested weir ? Trapezoidal (Cipolletti) sharp crested weir ? V-Notch (Triangular) sharp crested weir ? Parshall Flume ? ...
Premium
Orifice/gate 61 e. Weir 64 f. Flume 67 g. Flow measurement devices 69 h. ...
Premium
Im Taele 2 75031 Eppingen, Germany ® Software Manual NivuSoft Page 4 NivuSoft Manual, Rev. 02 as of 27.01.2014 1 Contents 1.1 Table of Contents 1 Contents ............................................................................................................ 4 1.1 Table of Contents ......................................................................................................... 4 ...
Premium
E-mail: [email protected] of TaskSolution• In order to protocol the hydrology of a dump it is necessary to record the delivery of a groundwater spring emerging within the dump area • Spring water tending to mineral sedimentation• Measuring shall be accurate, long-term stable and as low in maintenance efforts as possible• The measurement had to be implemented within the area ...
Gauger485 is a level sensor solution for applications interfacing external devices such as a radio modem, GPS receiver, multiple relay controller, WiFi converter, computing devices and many more. Gauger485 level sensors can also communicate with each other or with GaugerGSM for applications such as differential level measurement or adjacent multiple tank level measurements. The use of serial ...