Refine by
Applications
- Electroluminescence and Photoluminescence Spectroscopy of a Phosphorescent Organic Light Emitting Diode (PhOLED)
- Luminescence Thermometry with Upconversion Materials
- Determination of Chromaticity Coordinates and Bandgaps of III-V LEDs Using Electroluminescence Spectroscopy
- Time-Resolved Electroluminescence Spectroscopy of a White Light Emitting Diode
- Observing Phase Transitions in a Halide Perovskite Using Temperature Dependent Photoluminescence Spectroscopy
- Study of Fluorescence Quenching Kinetics Using Stopped-Flow
- Carbonaceous Aerosol Measurement Instruments for Black Carbon Car Emission Factors
- Comparing Hole Extraction Efficiencies in Perovskite Solar Cells using Photoluminescence Quantum Yield
- Energy Transfer in a Liquid Scintillator Investigated using Time-Resolved X-ray Excited Luminescence Spectroscopy
- Emission Tail of Indium Phosphide Quantum Dots Investigated using the FS5 Spectrofluorometer
- Sn to Mn Energy Transfer Revealed using Time-Resolved Emission Spectroscopy (TRES)
- Identifying Thermally Activated Delayed Fluorescence (TADF) using an FS5 Spectrofluorometer
- Fluorescence, Delayed Fluorescence and Phosphorescence Spectra of a TADF Emitter Measured using the FLS1000 with a VPL laser and Gated PMT Detector
- Photoluminescence Spectroscopy of Carbon Dots
- Relative Quantum Yield of 2-Aminopyridine
- Ligand Binding Assays on the Basis of Fluorescence Anisotropy
- Measuring Picosecond Fluorescence Lifetimes Using the FLS1000 Equipped with a Hybrid Photodetector
- Tuning the Photoluminescence of Graphene Oxide
- Photophysical Characterisation of Perovskite Quantum Dots
- Measuring Charge Carrier Lifetime in Perovskite Solar Cell Materials Using Time-Resolved Photoluminescence Spectroscopy
- Red-Edge Excitation Spectroscopy of Proteins with the FS5 Spectrofluorometer
- Molecular Beacon Probe Fluorescent Detection of DNA
- Time-resolved Spectroscopy of Phosphorescent Oxygen Sensors in a Relevant in vitro Environment for Biomedical Applications
- Temperature-Dependent Quantum Yield of Fluorescence from Plant Leaves
- Measuring Charge Carrier Lifetime in Halide Perovskite Using Time-Resolved Photoluminescence Spectroscopy
- Kinetics of Persistent Luminescence Phosphors
- Temperature Dependence of Phosphors via Photo-and Thermo-Luminescence
- Charge Carrier Recombination Dynamics of Semiconductor Photocatalysts
- Water Quality by Monitoring the Natural Organic Matter of Aquatic Systems
- Time Resolved Fluorescence Techniques to FRET Based Immunoassay
- Lipid-Protein Interactions Revealed by Fluorescence Spectroscopy
- Lanthanide-Based Up-Conversion Materials
- Oxygen and carbon dioxide analyzers for miscellaneous industries
- Oxygen and carbon dioxide analyzers for scientific and industrial
- Optical emission spectrometers instruments solutions for chemical & petrochemical industry
- Optical emission spectrometers instruments solutions for environment industry
- Optical emission spectrometers instruments solutions for pharmaceutical industry
- Optical emission spectrometers instruments solutions for clinical industry
- Chemical testing for environmental regulation and compliance
- Chemiluminescense based analyzer for industrial sector
- Data loggers and data acquisition monitoring solutions for the weather sector
Source Sampling Equipment & Supplies In Cuba
140 equipment items found
Manufactured by:Camsco, Inc  based inHouston, TEXAS (USA)
Utilizing the same sorbent tubes used for fenceline monitoring, a personal sampling pump can quickly pull grab samples for an instantaneous measurement. The Active Sampling Kit can be used for collecting ambient samples between the source and the monitoring station. The pump provided allows for larger volumes ...
Premium
Manufactured by:ECO Physics AGÂ Â based inDuernten, SWITZERLAND
The nCLD 822 Mr analyzer is the next generation in high precision two-channel nitrogen oxide measurement. Unique in speed and reliability, the nCLD 822 Mr is modular designed and capable of simultaneously measuring NO, NOx and NO2 from sources with pressure variations. It features a dual inlet option for assessing two different sources at once. The new and intuitive graphical user interface ...
Premium
Manufactured by:J.U.M. Engineering GmbHÂ Â based inKarlsfeld, GERMANY
The Model VE 222 is an efficient, all heated and low pressure drop 2-stream sample sequencer, filter and interface for removing solids from two gaseous sample streams. The Model VE 222 utilizes two independent permanently installed all stainless steel mesh sample filters and two independent all stainless steel sample valves in a thermostatic controlled oven to prevent the loss of high molecular ...
Premium
Manufactured by:Quantek Instruments, Inc.  based inGrafton, MASSACHUSETTS (USA)
O2 and CO2 Analyzer for research processes, gas blending, biotech, and other systems. The Model 902P O2 CO2 analyzer measures 0 to 100% O2 concentrations, and 0-1% to 0-100% CO2 vol/vol full scale, in a variety of process, research, and biotech applications. Options include internal sample pump, battery operation, analog outputs, and complete data collection option (including analysis software ...
Premium
Manufactured by:Chromatotec  based inSaint-André de Cubzac, FRANCE
Methane, Non-Methane Total Hydrocarbons and Total Hydrocarbons with ChromaTHC-OCU. When odor issues occur at an industrial site, rapid diagnosis must be done to define the best source treatment strategy. Manual sampling techniques can lead to problems during sampling and transport to the laboratory for analysis. Therefore, there is a need for ...
Manufactured by:Micro X-Ray  based inSanta Cruz, CALIFORNIA (USA)
The Lightbright is an X-ray tube designed for customers that require maximum flux, short FOD and a wide beam angle. This end window XRF tube enables a tight source/sample/detector geometry to optimize the amount of usable flux, allowing you to obtain high-quality spectra in less time. The Lightbright also include an integrated O-ring groove for compatibility with ...
Manufactured by:Udeyraj Electricals Private Limited  based inMumbai, INDIA
UDEY ‘CTPTA-504 is a comprehensive CT and PT analyzer. It’s constant voltage and current is highly stable. DSP system controls the constant voltage and current source output and amplitude. This source generates AC of 0-125V and or DC of 0-0.5A current to sample CT. The DSP system besides controlling the sources, also ...
Manufactured by:Meyer Burger  based inGwatt (Thun), SWITZERLAND
It can be adapted to RIE, PVD and PECVD and can process different substrate sizes up to 200 mm / 300 mm in diameter. The modular concept of MicroSys 200 / MicroSys 300 allows a customized setup of plasma sources and sample heating or ...
Manufactured by:Vitrocell Systems GmbHÂ Â based inWaldkirch, GERMANY
A sampling bag can be easily and directly connected to the module using the VITROCELL® SPIDER. The bag can be filled from various sources. If samples must be taken from the indoor/outdoor environment, VITROCELL® offers a special vacuum filling system for the sampling bag which is then transferred to the laboratory. ...
Manufactured by:Fusion Genomics Corporation  based inBurnaby, BRITISH COLUMBIA (CANADA)
It contains all the reagents (including QUANTUMProbes) to produce an enriched sequenceable library from a variety of sample sources (blood, nasal wash, NP swab, etc.) within 6 ...
Manufactured by:Hamamatsu Photonics  based inIwata City, JAPAN
Autofluorescence is gaining interest as a method to detect and identify aerosol biological agents because of its potential to minimize the cost of consumables associated with DNA-based detection systems. Instruments that rely on autofluorescence use an ultraviolet light source to excite biological samples, and then determine the size of particles by measuring ...
Manufactured by:Creative Biogene - Microbiotec  based inShirley, NEW YORK (USA)
Device Storage: RNA: Room temperature: 1 month, DNA: Room temperature: 2 years, DNA & RNA: -20?: Indefinitely. Sample Collection: 1 g or 1 mL stool sample. Sample Source: Stool ...
Manufactured by:Shandong Jingfeng Humic Acid Technology Co., Ltd  based inJinan, CHINA
Humic acid is formed by microbial degradation of the dead biological substances. Its specific properties and structure depending on a given sample source from water or soil to extract the specific conditions.Products we have are humic acid powder, granular humic acid and humic acid ...
Distributed by:Conquer Scientific LLCÂ Â based inPoway, CALIFORNIA (USA)
The Agilent 6495 Triple Quadrupole LC/MS achieves sensitivity and resolution specifications with autotune. Includes: Agilent 6495 Triple Quadrupole LC/MS System Jet Stream ESI Source (2) Roughing Pumps Data System Warranty Coverage Options: Additional Sources MS Sample Introduction Mass Spec Workbench Installation & Familiarization Extended ...
Manufactured by:ARCoptix S.A  based inNeuchâtel, NETHERLANDS
Thanks to its permanently aligned interferometer and solid-state reference laser, the FT-NIR Rocket offers excellent stability in both intensity and wavelength scales. The FT-NIR Rocket is compatible with light sources and sampling accessories (like fibers, cuvette folder, ...) typically used with array-detector based NIR ...
Manufactured by:Viola Vitalis ABÂ Â based inSpĂĄnga, SWEDEN
Furthermore, since FTIR spectrometers and chromatography may be combined, researchers can use such equipment to look at the workings of chemical reactions and the detection of unstable chemicals. A source, an interferometer, a sample compartment, a detector, an amplifier, an A/D converter, and a computer make up a typical FTIR spectrometer. Radiation from the ...
Manufactured by:VIG Industries  based inAnaheim, CALIFORNIA (USA)
Model 300/2 is designed to measure a two gasses (or three with oxygen option). The Model 300/2 optical bench consists of the IR source, sample cell, and patent pending detector. The source control circuit provides a controlled current square wave to the infrared source. No mechanical chopper is used so there are no moving parts ...
Manufactured by:Mechatest Sampling Solutions  based inNootdorp, NETHERLANDS
Sample probes are very important and mostly an underestimated part of the sampling system. Probes are designed for extracting a representative portion of the fluid sample source in the pipeline to the sampling system. A sample probe works as a filter, keeping dust, pipe scale and entrained liquid ...
Manufactured by:Bruker Corporation  based inBillerica, MASSACHUSETTS (USA)
The simplicity of using OpenSpot® Cards has driven us to produce the new DART®-OS source. Designed for streamlined sample analysis, DART® users can now just drop the card into the top opening to present the analyte in exactly the right position for successful analysis. After a few seconds the card is removed and discarded, leaving no solvent or vials ...
Manufactured by:Nu Instruments Ltd  based inWrexham, UNITED KINGDOM
Matrix independent calibrations, Lowest detection limits for C, N, O and other non-metallics, Cryo-cooled samples for low melting point difficult analyses. The Astrum is designed to test high purity materials with the best detection limits. The primary application of the Astrum GD-MS is the characterisation of high purity conductive and non-conductive materials. It is capable of ...
