Refine by
Applications
- Stack Emission Sampling for Emission Dust Sampling Options
- Stack Emission Sampling for Heavy Metal Sampling System
- Stack Emission Sampling for Mercury Sampling System
- Stack Emission Sampling for Hydrochloride Acid Chimney Sampling
- Stack Emission Sampling for Dioxin Sampling
- On-Line gas, particulate analyzers, flow monitors, data acquisition for combustion
- On-Line gas,particulate analyzers, flow monitors, data acquisition for cement plants
- On-Line gas,particulate analyzers, flow monitors, data acquisition for glass works
- On-Line gas,particulate analyzers, flow monitors, data acquisition for process control
Stack Gas Sampling Equipment & Supplies In Lithuania
20 equipment items found
Premium
Manufactured by:ENVEA based inPoissy, FRANCE
The dry extractive SEC system dries the gas sample at the sampling point, eliminating the necessity of an expensive heated sampling line. It uses an exclusive high performance permeation technique, designed to meet almost all gas sample conditions. Ideal for highly soluble and corrosive gases. Optional built-in temperature & velocity sensors or STACKFLOW 200 flow meter on the same ...
Premium
Manufactured by:ENVEA based inPoissy, FRANCE
Gas Sampling system for use in combination with low concentration analyzers (Ambient Air ...
Manufactured by:AMS Analitica based inPesaro, ITALY
It consists of a probe sampling device with a spout aimed in the opposite direction of the emission exhaust with a heated pre-filter to withhold any particles interfering with the sample (device provided for monitoring of SOx and NOx, SOV without heating). The StackGas 2001 probe is configured to allow the user easy sampling. It is available with two standard suction tube lengths: 350 and 750 mm. ...
by:CMC Solutions, LLC based inFarmington Hills, MICHIGAN (USA)
The SmartCEMS® Sample Interface Panel is a component of a predictive emission monitoring system (PEMS) that provides for continuous stack gas sampling for pollutants and diluents under U.S. EPA 40 CFR Part 60 and/or U.S. EPA 40 CFR Part 75 regulations. The Sample Interface Panel will meet the requirements for ...
by:CMC Solutions, LLC based inFarmington Hills, MICHIGAN (USA)
The SmartCEMS® Probe is a component of a predictive emission monitoring system (PEMS) that provides for continuous stack gas sampling for pollutants and diluents under U.S. EPA 40 CFR Part 60 and/or U.S. EPA 40 CFR Part 75 regulations. The Probe will meet the requirements for sampling during model development and PEMS QA ...
by:CMC Solutions, LLC based inFarmington Hills, MICHIGAN (USA)
The SmartCEMS® Sample Line is a component of a predictive emission monitoring system (PEMS) that provides for continuous stack gas sampling for pollutants and diluents under U.S. EPA 40 CFR Part 60 and/or U.S. EPA 40 CFR Part 75 regulations. The Sample Line will meet the requirements for ...
by:CMC Solutions, LLC based inFarmington Hills, MICHIGAN (USA)
The SmartCEMS Portable Gas Analyzer System is a component of a predictive emission monitoring system (PEMS) that provides for continuous stack gas sampling for pollutants and diluents under U.S. EPA 40 CFR Part 60 and/or U.S. EPA 40 CFR Part 75 regulations. The Portable Gas Analyzer System can test up to 6 gases ...
Manufactured by:Sterlitech Corporation based inAuburn, WASHINGTON (USA)
With its lightweight construction, the Rocker vacuum pump is not only suitable for laboratory liquid vacuum filtration, but is also perfect for stack or ambient gas sampling as ...
Manufactured by:Samplebags.eu based inGroningen, NETHERLANDS
The Tedlar gas sampling bags are made of DuPont’s 2mil Tedlar® PVF film. Tedlar® PVF film is tough, durable, and considered chemically inert to a wide range of compounds. Bags of Tedlar film can be used for indoor air sampling, hazardous waste sites, leaking underground storage tanks, stack ...
Manufactured by:CEL Scientific Corporation based inCerritos, CALIFORNIA (USA)
2-in-1 fittings available in polypropylene (left), stainless steel (middle), and PTFE (right). New design fully automatic vacuum air sampling box is available to order NOW!, CEL Scientific gas sampling bags are made of DuPont's 2mil Tedlar® PVF film. Tedlar® PVF film is tough, durable, and considered chemically inert to a wide range of ...
Manufactured by:CEM Specialties Inc. based inLondon, ONTARIO (CANADA)
Industrial plants requiring approval are subject to strict requirements for compliance of emissions limit values. For monitoring it is only allowed to use measuring devices approved by the Federal Environment Agency. The approval requirements are defined in EN 15267. The number of measured components depends on the plant type, but also on the used ...
Manufactured by:CEM Specialties Inc. based inLondon, ONTARIO (CANADA)
Industrial plants requiring approval are subject to strict requirements for compliance of emissions limit values. For monitoring it is only allowed to use measuring devices approved by the Federal Environment Agency. The approval requirements are defined in EN 15267. The number of measured components depends on the plant type, but also on the used ...
Manufactured by:Flo-Corp based inMedina, OHIO (USA)
The FLO-CORP CalFlo CFAM Thermal Mass Air Flow Meter is well suited for small pipes up to 3/4” in diameter. The ideal solution for gas applications, from vent gas to nitrogen blanket flow. ...
Manufactured by:HiTemp Tech Corporation based inRingoes, NEW JERSEY (USA)
HiTemp Process Furnace Systems are designed and manufactured for low and high BTU solids using a combination of temperature and destructive distillation to breakdown the combustibles. An afterburner system separately controls adding secondary combustion air to raise the temperature of the exhaust gases to the required operating temperature, eliminating any smoke or ...
Manufactured by:Olfasense Group based inKiel, GERMANY
Olfasense is reseller of Kynar PVDF and Tedlar sampling bags made from PVDF, offering sizes from 0.5 L to 1000 ...
Manufactured by:Shinhan Tech based inGeumcheon-Gu, SOUTH KOREA
Sampling Unit. Designed for outdoor mounting. Distance between Sampling and Control Units can be up to 100m. There is no need to put in or out the stack for each sampling. Easy substitution of filter holder cartridge, adsorbing trap and collection ...
Manufactured by:Nutech Instruments Inc. based inPlano, TEXAS (USA)
Tedlar bags are recommended in many US EPA methods including TCLP and methods TO-3 (VOCs), TO-12 (NMOC), TO-14A (VOCs), TO-15 (VOCs), ASTM D-5504 (reduced sulfur compounds) and a variety of atmospheric gas ...
Manufactured by:HORIBA Europe GmbH based inLeichlingen, GERMANY
HORIBA Europe’s NOx Converter Checker CC-100E has been developed to test the e'ciency of NOx to NO converters, which are used in NOx gas analyzers for stack emission measurements or process gas ...
Manufactured by:Westech Scientific Instruments (Westech) based inUpper Stondon, UNITED KINGDOM
The M9096 In-Stack Manual Method Particulate Sampler for ISO9096, EN13284-1, US EPA Method ...
Manufactured by:TCR-Tecora based inCogliate (MB), ITALY
Bravo DUO is a constant flow sampler with 2 diaphragm pumps and double heads! The heart of BRAVO DUO consists of two diaphragm pumps resistant to aggressive gases. Flow control is assured by a microprocessor ...