Refine by
Applications
- Steel Thickness Gauges for Marine Applications
- Wastewater Aeration for Sugar Industry
- Wastewater Aeration for Meat and Protein Industry
- Wastewater Aeration for Distilling Industry
- Wastewater Aeration for Contractors
- Industrial
- Membrane Water Treatment and Monitoring Products for Boiler and Cooling
- Water Immunoassay Test Kits for Contaminated Land and Water
- Water Treatment Solution for Industrial Water Treatment and Zero Liquid Discharge (ZLD)
- Water Treatment Solution for Sea Water Desalination
- Water Treatment Solution for Residential – Safe Drinking Water
- Water Treatment Solution for Microbrewery Water Treatment/Reuse
- Wastewater Aeration for Chemical Industry
- Wastewater Aeration for Pulp and Paper Industry
- Wastewater Aeration for Dairy & Cheese Industry
- Wastewater Aeration for Landfills Treating Leachate
- Wastewater Aeration for Petroleum Industry
- Wastewater Aeration for Food Processing Industry
- Wastewater Aeration for Pharmaceutical Industry
- Wastewater Aeration for Beer Industry
- Wastewater Aeration for Wine Industry
Membrane Testing Equipment & Supplies
175 equipment items found
Manufactured by:Sterlitech Corporation based inAuburn, WASHINGTON (USA)
The unique design of the CF042 test cells allows flat sheet membranes to be quickly changed out, thus reducing time between trials. Skids are available in single or multiple cell configurations in both parallel and series modes. The skid system also displays and records the data collected by the integrated sensors in real-time. ...
Manufactured by:Sterlitech Corporation based inAuburn, WASHINGTON (USA)
Refurbished Membrane Test Skid, 3x CF042 in parallel, Digital, VFD, Scale, Chiller, 110V, 60Hz, ...
Manufactured by:Sterlitech Corporation based inAuburn, WASHINGTON (USA)
This system has been specifically configured for use with standard 1812 and 2540 spiral wound elements in parallel with Sterlitech cross flow cells, including Sepa, CF042, and ...
Manufactured by:Guochu Technology (Xiamen) Co., Ltd based inHaicang District, CHINA
Flat membrane test equipment can be widely used in solid-liquid separation, clarification and filtration, sterilization and dehumidification, material concentration and other research. The molecular weight has a range of 1KD-20KD that one can choose from, with 10 times higher in accuracy than regular ceramic membrane filtration. One can choose ...
Manufactured by:Sterlitech Corporation based inAuburn, WASHINGTON (USA)
The unique design of the Sepa test skids allow flat sheet membranes to be quickly changed out, thus reducing time between trials. Skid systems are available in single or multiple cell configurations in both parallel and series modes. The skid system also displays and records the data collected by the integrated sensors in real-time. ...
by:Messinger Engineering based inZürich, SWITZERLAND
Our new ceramic membrane test system CM-1, equipped with ceramic membranes and advanced measurement tech, is a key element in researching and engineering ceramic membrane filtration processes. CM-1 precisely controls and maintains constant experimental parameters such as temperature, pressure, flow rate and calculated ...
by:Messinger Engineering based inZürich, SWITZERLAND
The CT-1 test system for individual ceramic tubular membranes was developed in response to urgent requirements in the industry. Customers seek a user-friendly, easy-to-understand ceramic membrane system for their initial trials. However, the system must also provide reliable results that can be used for scaling up. It must also be possible to ...
by:Messinger Engineering based inZürich, SWITZERLAND
Laboratory plant for membrane filtration / membrane technology. Benchtop system with a single ceramic tubular membrane. The properties of the ceramic, such as high overflow, high temperatures, pH stability, etc., can be fully utilised thanks to the solid, high-quality design and the installed components. ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Uniform Temperature Membrane Test Rig used to test hydrogen permeation in disc or tube (specify) membranes at pressures up to 300 psi and temperatures up to 450 C. Stainless Steel, 1.75" OD with an interior volume 1.4" ID" by 8" or 18" long, sealed by a copper or graphite gasket. A counter flow annulus provides improved ...
Manufactured by:Sterlitech Corporation based inAuburn, WASHINGTON (USA)
Sterlitech 1812 Membrane Test Skids are designed to evaluate the performance of membranes widely used in Reverse Osmosis, Nanofiltration, Ultrafiltration, and Microfiltration applications by simulating the flow dynamics of larger, commercially available membrane systems. This test skid offers experimental control ...
Manufactured by:Sterlitech Corporation based inAuburn, WASHINGTON (USA)
The Sterlitech Forward Osmosis Membrane Test Skid is designed to evaluate the performance of Forward Osmosis membranes under varying conditions. This test skid offers experimental control by allowing adjustment of the flow parameters to accommodate a wide range of operating conditions and applications. ...
Manufactured by:Porometer a Division of Aptco Technologies Nv based inNazareth, BELGIUM
The High Throughput (HT) dead-end filtration module for single feed liquid filtration, SPIDER™is built in stainless steel and it is suitable for both water or solvent based feed solutions. In one single experiment it is possible to carry out either 8 or 16 simultaneous dead-end filtrations (depending on the SPIDER™model), which supposes an extreme gain of time compared to conducting ...
Manufactured by:DeltaE Srl based inQuattromiglia (CS), ITALY
The “Experimental Setup for Flat and Hollow membrane testing” has characteristics of stability and reliability that make it suitable for use in research. This unit is designed for general purpose applications requiring a robust, secure and low-cost ...
Manufactured by:REB Research & Consulting based inOak Park, MICHIGAN (USA)
Higher Pressure Membrane Test Rig, 21" tall by 1.5" outer diameter; 7/8" ID, used to test hydrogen permeation at pressures up to 600 psi and temperatures up to 650 C. Test volume is 18" long, with a counter-flow annulus for improved temperature uniformity. Test volume sealed with a 1" swagelok fitting. ...
Manufactured by:DeltaE Srl based inQuattromiglia (CS), ITALY
Circular stainless steel cell for flat membrane for test with gas. Membrane test distillation, membrane test reverse ...
Manufactured by:DeltaE Srl based inQuattromiglia (CS), ITALY
The “Experimental Setup for Hollow membrane testing” has characteristics of stability and reliability that make it suitable for use in research. This unit is designed for general-purpose applications requiring a robust, secure and low-cost ...
Manufactured by:DeltaE Srl based inQuattromiglia (CS), ITALY
Flat Cell for Polymeric Membrane: Material: steel AISI 316L. N. 2 GAS-IN input for tubing ¼”. N. 2 GAS-OUT input for tubing ¼”. Operative Pressure: Up to ...
Manufactured by:DeltaE Srl based inQuattromiglia (CS), ITALY
This cell is suitable for testing membrane in Ultrafiltration (UF), Microfiltration (MF), Nanofiltration (NF) and Reverse Osmosis ...
by:Pantreon GmbH based inGmunden, AUSTRIA
For lab testing 0,037m² filtration area. Simulation of ZELIX flow technology on a laboratory scale! ...
Manufactured by:PCI Membranes - Filtration Group based inFareham, UNITED KINGDOM
The MIC-RO 240 and 960 are designed for economic, short-term evaluation of membrane processes for separation and concentration at laboratory bench scale. It is a small stainless steel tubular device, 30cm long for the MICRO 240 and 1.2m long for the MICRO960, which accepts two 12.7mm diameter membrane tubes. The module is capable of operating at pressures of up ...