Refine by
Pcb Sampling Equipment & Supplies
14 equipment items found
Manufactured by:Fluid Management Systems, Inc. (FMS) based inBillerica, MASSACHUSETTS (USA)
Sample cleanup is a very important step because methods often don’t respond to the analyte in its in-situ form, or the results can be distorted by interfering species. Column cleanup is used to eliminate interferences that can occur in the sample matrices. Multi-column cleanup procedures use multiple column chemistries to remove interferences and fractionate analytes of interest from ...
Manufactured by:Fluid Management Systems, Inc. (FMS) based inBillerica, MASSACHUSETTS (USA)
Imagine performing the Sample Cleanup process for POPs analysis in liquids and solids automatically in as little as 30 minutes. Built on 25 years of FMS, Inc. experience and technology that has processed millions of Dioxin samples, FMS introduces a new family of integrated, economical sample cleanup systems that combine manual ...
Manufactured by:Eigenbrodt GmbH & Co. KG based inKönigsmoor, GERMANY
The all new SD-card data logger allows in combination with Eigenbrodt signal PCBs to log the data sets on SD-memory cards. This allows retrieving the data simply by replacing the SD-card. The unit is easy to operate: Just push in the SD-card and the logging file is automatically been created. All data from this point of time will be written to the SD-card. ...
Manufactured by:Sigma-Aldrich based inBellefonte, PENNSYLVANIA (USA)
This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational analyses of PCB-containing samples USP Code: none Phase: • Bonded • Poly(50% n-octyl/50% methyl siloxane) Temp. Limits: • ≤0.32 mm I.D.: -60 °C to 280 °C (isothermal or programmed) • ≥0.53 mm ...
Manufactured by:Sigma-Aldrich based inBellefonte, PENNSYLVANIA (USA)
This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational analyses of PCB-containing samples USP Code: none Phase: • Bonded • Poly(50% n-octyl/50% methyl siloxane) Temp. Limits: • ≤0.32 mm I.D.: -60 °C to 280 °C (isothermal or programmed) • ≥0.53 mm ...
Manufactured by:Dexsil Corporation based inHamden, CONNECTICUT (USA)
The CLOR-N-SOIL field screening kit detects PCB in soil samples. In 10 minutes the test will tell you if your sample contains greater or less than 50 ppm PCB. The kit can test any kind of soil including sand, topsoil, sediment and ...
Manufactured by:Sigma-Aldrich based inBellefonte, PENNSYLVANIA (USA)
This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational analyses of PCB-containing samples USP Code: none Phase: • Bonded • Poly(50% n-octyl/50% methyl siloxane) Temp. Limits: • ≤0.32 mm I.D.: -60 °C to 280 °C (isothermal or programmed) • ≥0.53 mm ...
Manufactured by:Sigma-Aldrich based inBellefonte, PENNSYLVANIA (USA)
This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational analyses of PCB-containing samples USP Code: none Phase: • Bonded • Poly(50% n-octyl/50% methyl siloxane) Temp. Limits: • ≤0.32 mm I.D.: -60 °C to 280 °C (isothermal or programmed) • ≥0.53 mm ...
Manufactured by:Sigma-Aldrich based inBellefonte, PENNSYLVANIA (USA)
This column offers unique selectivity compared to non-polar and intermediate polarity columns, and can be used for confirmational analyses of PCB-containing samples USP Code: none Phase: • Bonded • Poly(50% n-octyl/50% methyl siloxane) Temp. Limits: • ≤0.32 mm I.D.: -60 °C to 280 °C (isothermal or programmed) • ≥0.53 mm ...
Manufactured by:Phenomenex based inTorrance, CALIFORNIA (USA)
Unique low polarity si-arylene column for MS detectors. Provides alternative selectivity to standard 5-type phases. Often used for confirmation of pesticide, PCB, or other environmental sample. Good tool for sample screening to identify unknown ...
Manufactured by:LCTech GmbH based inObertaufkirchen, GERMANY
Automated Sample Clean-up with DEXTech Heat For PCB and Dioxin Samples Hardening at Room Temperature. Samples like PFADs or stearin get solid at room temperature. DEXTech Heat has been developed especially for these ...
Manufactured by:Nordson TEST & INSPECTION based inCarlsbad, CALIFORNIA (USA)
SQ3000+ Multi-Function System with Multi-Reflection Suppression® (MRS®) sensor technology provides the ultimate combination of high resolution, high accuracy and high speed for inspection and metrology. It remains the only system on the market capable of performing AOI, SPI and CMM ...
Manufactured by:LCTech GmbH based inObertaufkirchen, GERMANY
Before or after sample clean-up in PCB and dioxin analysis, it is often necessary to concentrate the samples to a lower ...
Manufactured by:Comde-Derenda GmbH based inStahnsdorf, GERMANY
Sampling inlets for SPM samplers, sampling systems and real-time monitoring devices. All Comde-Derenda sampling inlets, also known as sampling heads, have been designed and tested specifically for use with our sampling and monitoring systems. They are suitable for measuring various substances, including ...
