Model PI-200 -Online Process Raman System
The PI-200 Raman instrument offers a number of applications in process monitoring, and chemical analysis. The combined use of a Laboratory system for property modeling, in conjunction with an online process monitoring system, will give accurate, realtime measurement of chemical properties within a process. Saving critical time, and in the end, critical cost.
Most popular related searches
fiber optic raman probe
Raman probe
fiber optic probe
process monitoring system
raman
wavelength calibration
process monitoring
fiber optic raman
raman system
digital temperature controller
With the 1200 grooves/mm grating, the spectral coverage is ~ 2100 cm-1 at 785 nm excitation. The grating is adjustable to allow use with excitation from 670 to 860 nm. The spectra can be exported in SPC or ASCII formats.
Excitation Source
- 785 nm Frequency Stabilized, Narrow Linewidth Laser.
- Laser power (adjustable): 450 mW standard.
- Higher power levels available - up to 1,500mW
- Line width ~ 1.0cm-1.
- Wavelength accuracy ± 0.1nm.
- Wavelength repeatability (on/off) -< 0.15 cm-1 .
- Wavelength stability -< 0.3 cm-1drift per week.
- Laser lifetime -1 year warrenty (6 year projected lifetime).
- Patented design - Pat. No. 6,100,975.
Raman Fiber Optic Probe
- Inphotonics Raman Probe standard (other probes types available).
- 200µm diameter excitation fiber, 400µm collection fiber.
- Focal length - 5mm standard, 3 meter fiber optic cable.
- Rayleigh filtering built into probe tip (>8 O.D.).
- System can accommodate most any Raman probe configuration.
- Probes manufactured from 316-SS, carbon steel, alloy-20, hastelloy, etc.
- Ball probes also available.
- Lowest Raman shift that can be measured ~225 cm-1.
- ATEX Zone 0 certified.
CCD Detector
- Andor DU401-FI (standard) Higher performance CCD detectors available.
- TE cooling to < -60° - 82° C for low noise applications.
- Pixel size = 26 µm square and full range area of 128 x 1024 pixels.
- Other CCD configurations available; e.g., 256 x 1024 pixels..
Spectograph
- Spectograph aperture: f/2.0.
- Focal length: 135 mm.
- Patented design: No. 6,028,667.
- Diffraction grating: 1200 grooves/mm, ruled standard (other gratings available upon request).
- Resolution: 4 cm-1with 785 nm excitation.
- Spectral coverage: with 785 nm excitation ~2100 cm-1, with 830 nm excitation the spectral coverage is ~1900 cm-1 .
- Fiber optic coupling: bundle to slit adapter with 100 µm fibers (17 fibers) in a linear input array (3.3 mm high) for coupling to spectrograph.
- Temperature controlled: ~30° C for added stability.
- Image curvature at exit plane: < 0.5 pixel over full height of CCD array.
- User adjustable center wavelength via rotating grating.
- Builtin neon lamp for wavelength calibration.
Packaging
- Online 19" rack mount dimensions (80" x 23" x 40"), weight ~ 430 lbs.
- Online Purged enclosure rack mount (72" tall x ~ 28" wide x ~ 36" deep)
Multiplexing
- Up to 18 channels with fiber switcher (17” x 17” X 10”), weight 55 lbs.
- Insertion loss is less then 1 dB.
- Switching time between channels is ~ 0.5 s.
- Patented design: No. 6,859,581B1.
Online Instrument
- Includes backup laser with an AUTO SWAP feature to automatically switch in the backup laser should the primary laser fail.
- Includes a backup computer with hot swappable ARAID drives that can be quickly used if the primary computer should fail.
- Lasers can be easily switched out with no user optical alignment.
- Software features include automatic X- and Y-axis calibration, real time chemometrics, and continuous laser tracking to ensure stable operation.
- Backup features along with auto calibration ensure that there is minimal downtime (typically < 2 hours/year/channel).
- Includes modeling for 1st year of use, model training at our facility.
- Remote monitoring of system health available.
System Software
- Data collection with real time chemometrics, laser frequency tracking, multipoint neon lamp absolute wavelength calibration, and throughput normalization features for chemometric model transfer capability.
- Auto calibration features available
- Interface with a DCS system, RS485, RS232, or TCP/IP .
- Data files can be exported into ASCII and SPC formats.
System Stability
- Amplitude stability ± 0.2 % over 24 hours after 30 minutes warmup.
- Frequency stability ± 0.1 cm-1 over 24 hours after 30 minutes warmup.
Power Requirements
- 115 to 230 VAC, 47 to 63 Hz, 10A
System Warranty
- Two year on both laser and instrument.