Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Applications
  3. respirometer
Show results for
Products
Services
Applications

Companies

News
Articles
Books
Downloads
Videos

Refine by
Locations

  • USA
  • Europe
  • Asia & Middle East
  • Australasia
  • Latin America
  • North America
Industries served

  • Monitoring and Testing
  • Water and Wastewater
  • Pulp & Paper
  • Waste and Recycling
  • Air and Climate
  • Soil and Groundwater
  • Manufacturing, Other

Respirometer Product Applications

28 applications found

Research Respirometer Equipment for Resting the Toxicity of a Cleaning Agent
Premium

Research Respirometer Equipment for Resting the Toxicity of a Cleaning Agent

METHOD: A seed culture from a full-scale anaerobic digester was placed in a number of 200 mL respirometer vessels. A synthetic wastewater having a 20,000 mg COD/L in a nutrient/ mineral/buffer solution was fed daily to each reaction vessel — along with various amounts of the cleaning agent The reactors were operated for a four day test period with measurement of gas production using a CHALLENGE ANR-200 anaerobic ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Respirometry system for aerobic toxicity testing

Respirometry system for aerobic toxicity testing

This example shows the results of respirometer tests in which three concentrations of cyanide were added to a aerobic test culture that received phenol as an organic substrate. ...

ByRespirometer Systems and Applications, LLC (RSA)  based in  Fayetteville, ARKANSAS (USA)


Research respirometer equipment for biochemical oxygen demand measurement sector
Premium

Research respirometer equipment for biochemical oxygen demand measurement sector

Test Setup: A series of dilutions consisting of 50, 75, 100, 125, 150, and 175 mL of test wastewater were added to respective 500 mL respirometer flasks along with nutrients, minerals, and buffers. TCMP was added to eliminate interference from nitrification. Oxygen uptake was measured over a five-day test period using a CHALLENGE AER-200 ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Industrial Waste Treatability Industry
Premium

Research Respirometer Equipment for Industrial Waste Treatability Industry

Test Setup: 40 and 60 mL of wastewater were added to individual respirometer flasks each containing nutrient/mineral/buffer medium to form two different dilutions. ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Oxygen monitoring from aerobic and anaerobic for toxicity test

Oxygen monitoring from aerobic and anaerobic for toxicity test

Toxicity of pure chemicals is assessed using respirometers by adding increasing concentrations to an active culture. The concentration at which oxygen uptake or gas production begins to decrease is known as the “threshold toxicant ...

ByRespirometer Systems and Applications, LLC (RSA)  based in  Fayetteville, ARKANSAS (USA)


Research Respirometer Equipment for Anaerobic Applications Sector
Premium

Research Respirometer Equipment for Anaerobic Applications Sector

The CHALLENGE AER-200 Respirometer System consists of one or more biological reaction vessels, gas flow measuring cells, and a computer. ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Application of respirometry system for nitrification testing

Application of respirometry system for nitrification testing

This case study shows how respirometers can be used to measure the impact of an industrial wastewater on the nitrification reaction in a treatment plant. ...

ByRespirometer Systems and Applications, LLC (RSA)  based in  Fayetteville, ARKANSAS (USA)


Oxygen monitoring from aerobic and anaerobic for biomass activity tests

Oxygen monitoring from aerobic and anaerobic for biomass activity tests

Pulse-Flow respirometers can be used to assess biomass activity for aerobic and anaerobic reactions. ...

ByRespirometer Systems and Applications, LLC (RSA)  based in  Fayetteville, ARKANSAS (USA)


Research Respirometer Equipment for Pharmaceutical Wastewater Industry
Premium

Research Respirometer Equipment for Pharmaceutical Wastewater Industry

A pharmaceutical company was interested in knowing whether a specific component, MCB, inhibited the biodegradation of other wastewater constituents. A series of respirometer tests was set up using identical mixtures of wastewater and return activated sludge (RAS) plus varying amounts of MCB. ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Culture Activity Tests Sector
Premium

Research Respirometer Equipment for Culture Activity Tests Sector

Waste Type:Synthetic (Acetic Acid). Objective: To monitor the gas produced by steady-state cultures receiving acetate as the input substrate. Another objective was to verify the consistency of gas production over a period of time as a means of verifying culture stability and test ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Respirometry system for biomass activity testing sector

Respirometry system for biomass activity testing sector

Pulse-Flow respirometers can be used to assess biomass activity for aerobic and anaerobic reactions. ...

ByRespirometer Systems and Applications, LLC (RSA)  based in  Fayetteville, ARKANSAS (USA)


Research Respirometer Equipment for Modeling of Methane and Hydrogen Production
Premium

Research Respirometer Equipment for Modeling of Methane and Hydrogen Production

Waste Type: Synthetic (Ethanol). Objective: To model the methane produced from acetate and from hydrogen in cultures receiving ethanol as an input substrate. The objective was to verify the accuracy of models developed on the basis of substrate ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research respirometer equipment for biodegratation kinetics of industrial wastes sector
Premium

Research respirometer equipment for biodegratation kinetics of industrial wastes sector

Samples of the industrial wastewater were collected and oxygen uptake for four dilutions was measured using a CHALLENGE AER-200 aerobic/anaerobic respirometer system. Biodegradation kinetic coefficients were determined using the method described by Dang, et. al. ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Pesticide Degradation
Premium

Research Respirometer Equipment for Pesticide Degradation

Measurement of oxygen uptake of the pesticides: carbaryl, carbofuran and aldicarb in samples seeded with microorganisms extracted from ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Testing the Stability of Compost Sector
Premium

Research Respirometer Equipment for Testing the Stability of Compost Sector

The reaction vessels were connected to a Challenge AER-200A respirometer system for measuring the oxygen ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Respirometer Applications

Respirometer Applications

Measurement of the aerobic biodegradability of plastic materials (US Standard ASTM D5338, European Standard ISO ...

ByECHO Instrumenst d.o.o.  based in  Slovenske Konjice, SLOVENIA


Research Respirometer Equipment for Pulp Mill Wastewater Industry
Premium

Research Respirometer Equipment for Pulp Mill Wastewater Industry

A pulp mill was interested in evaluating the impact of increasing organic loading rates on the performance of their activated sludge ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Research Respirometer Equipment for Toxicity Testing
Premium

Research Respirometer Equipment for Toxicity Testing

Waste Type: Complex alcohols. Objective: Certain constituents of the test waste were know to be biodegradable but were suspected of being toxic to aerobic biological processes when present in high concentrations. The objective was then to determine how much waste could be added to an activated sludge process before toxic impacts would be ...

ByChallenge Technology  based in  Springdale, ARKANSAS (USA)


Analytical Instruments for Biodegradability & Compostability

Analytical Instruments for Biodegradability & Compostability

In aerobic environments, the biodegradability is usually determined by measuring oxygen demand in a closed respirometer or the amount of carbon dioxide evolved over time. ...

ByBPC Instruments AB  based in  Lund, SWEDEN


Waste water respirometry solutions for toxicity reduction tests

Waste water respirometry solutions for toxicity reduction tests

Following a period of acclimatisation it is often possible to increase feed rates to the plant and this can again be managed using the Strathtox Respirometer. An alternative approach is to undertake toxicity reduction procedures, such as neutralisation or acid hydrolysis, in pilot-scale laboratory studies. ...

ByStrathkelvin Instruments Limited  based in  North Lanarkshire, UNITED KINGDOM

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT