Refine by
Respirometer Articles & Analysis
44 articles found
Using Anaerobic + OxyShark® High-Purity Oxygen, Fixed-Film Bioreactor. OxyShark® Water Reclamation Solutions was commissioned to accomplish two goals for a landfill gas production ...
Once the results of this type of tests have been obtained, when confirmed the presence of toxicity, we can optionally go to a second step in which we could determine the maximum allowed flow to be treated without any toxicity. 2. Operation modes of a BM respirometer The BM respirometry systems from Surcis, S.L. (www.surcis.com) include three different operational modes, thus ...
Three different operation modes While most of the respirometers on the market offer only one operation mode, the BM respirometers have three different operation modes: OUR mode, Cyclic OUR mode, and R mode. ...
As proof-of-principle, an exemplary system consisting of the second vessel of a hybrid respirometer has been studied. The system has been modeled both using an integrated computational fluid dynamics (CFD)-biokinetic model (assumed to represent the physical system) and a tanks-in-series, completely stirred tank reactor biokinetic model (representing the applied model). ...
However, is also important to stress that the effectiveness of the respirometric tests, results and conclusions will largely depend on the type of respirometry in use, since the respirometer must have the ability to accurately determine the stoichiometric yield coefficient, automatic measurements of the COD biodegradable fractions within relatively short time, as well as the ...
Vanrolleghem. 2002). 2. BM RESPIROMETER The methods and case study described in this paper were carried out with parameters and calculations resulting from a test performed using an advanced respirometer. This respirometer is able to conduct tests within different ranges of temperature, pH and DO. ...
At present SURCIS is manufacturing three new generation BM respirometers: BM‐EVO, BM‐T+ and BM‐Advance 1. Three different operation modes in one analyzer While most of the respirometers in the market offers only one operation mode, the BM respirometers have got three different operation modes: OUR mode, cyclic OUR mode and ...
He also has to know if it is enough or not; and in case of not enough, he has to find out the causes and the possible solutions. For that purpose, a BM respirometer can be the perfect instrument to measure the actual nitrification rate and also to analyze if this has a higher or lower value than it is required in any specific process. By other side, assuming that we cannot ...
It acquires special importance the determination of the non-biodegradable COD and specific Toxicity, because many times they can explain why some processes are unable to sufficiently remove the COD entering in the plant and give a coherent explanation to the water-agencies or official control organisms. BM Respirometers for ASP This is a new concept of laboratory respirometry ...
BM Respirometry makes use of a single reaction vessel, that in certain modes, can replicate the actions that occur at a treatment plant within the conditions set for the test. The BM-respirometers, using powerful software, provide a way to set measurements and calculations for decisive parameters used to manage, design, and research the biological processes of wastewater ...
Respirometer The respirometer utilized in this study corresponds to the BM-Advance model, with the following main features: Compact analyzer, with very low maintenance and user friendly operation Direct oxygen measurements from a maintenance-free oxygen sensor No oxygenation restriction during test performance Full control and results by means a powerful ...
BM Respirometry makes use of a single reaction vessel, that in certain modes, can replicate the actions that occur at a treatment plant within the conditions set for the test. The BM-respirometers, using powerful software, provide a way to set measurements and calculations for decisive parameters used to manage, design, and research the biological processes of wastewater ...
The CHALLENGE AER-200 Respirometer System consists of one or more biological reaction vessels, gas flow measuring cells, and a computer. ...
Rainbow trout (Oncorhynchus mykiss) confined to respirometer‐metabolism chambers were dosed with perfluorooctane sulfonate (PFOS) by intra‐arterial injection and sampled to obtain concentration time‐course data for plasma, and either urine or expired water. ...
This “batch system” respirometer consists of: a single thermostatically controlled vessel, divided into two interconnected compartments with closed recirculation loop between the two. ...
SURCIS, by means of its BM-T respirometer demonstrated however that after some controlled period of adaptation to the activated sludge, the wastewater was not only at all toxic but also presented a high degree of biodegradability. ...
For this protocol here explained we can use any of the BM respirometers, but in case the pH could play a critical role in its performance, it would be recommended the model BM-Advance which includes an automatic pH monitoring and control system. The BM respirometer can be programmed with three different operation modes (OUR, Cyclic OUR and R) and can be set for ...
In this study the effects of the olive oil in the activated sludge process are analyzed by making use of the BM-T multifunction respirometer from SURCIS, S.L. (Spain) and its powerful software to obtain the different COD biodegradable fractions, overlaying Respirograms and determining the actual COD uptake rate. ...
Data for study interest Aeration system: fine bubble diffusers + liquid oxygen injection Ammonium concentration in ASP influent: 42 mg N-NH4/L Ammonium concentration in effluent: 39 mg N-NH4/L SVI: 65 mL/g F/M: 0.078 kg BOD/kg MLVSS*d Dissolved oxygen average in aeration tank: 0.02 mg/L Kg O2/kWh in aeration system: 4 kg O2/kWh Power installed in aeration system: 148 kW (37 kW x 4 ...
The waste is very varied, covering everything from leachates at only 2000ppm COD to industrial waste at up to 500,000ppm COD. The Strathkelvin respirometer forms a central part of the testing procedure that determines how much of any material the Bio-plant can safely ...