Logo XPRT
Companies
Products
Services
Software
Training
Applications
Sign in
List your business

Advertising options
  1. Home
  2. Articles
  3. bod load
Show results for
Products
Services
Applications

Companies

News
Articles
Books
Downloads
Videos

Refine by
Date

  • Older

Bod Load Articles & Analysis

43 articles found

Sugar Factory Wastewater Treatment Plant - Case Study

Sugar Factory Wastewater Treatment Plant - Case Study

A Sugar Factory Wastewater Treatment Plant Experiences a Large Reduction in BOD/COD Levels The Newterra® Aire-O2® Triton Systems provides a reliable, efficient solution in a challenging environment. ...

ByNewterra, Ltd.


Volume 21: Does Your Whale System Make You Bellow?

Volume 21: Does Your Whale System Make You Bellow?

Synopsis: Systems that dilute wastewater before depositing it into the ocean will deposit concentrated wastewater when they fail – violating environmental regulations. Application: The MarineFAST® treats, rather than dilutes, wastewater, and operates without needing to release wastewater into the ...

ByBioMicrobics, Inc


58% Total Solids Reduction in 8MG Lagoon - Case Study

58% Total Solids Reduction in 8MG Lagoon - Case Study

Solids build-up in this open anaerobic lagoon in Tennessee was hampering operations at a large US industrial food waste rendering plant. In just four months, a single application of Bio Dredger biocatalyst broke down solids, with samplings analysis showing 58% Total Solid Reduction (TSR) and 60% Volatile Solid ...

ByBio Dredger - Drylet, Inc.


EcoFarmer Sewage Treatment for Santos Remote Camp - Case Study

EcoFarmer Sewage Treatment for Santos Remote Camp - Case Study

Client: Santos Location: Tarbat, Queensland Technology implemented: EcoFarmer 50 Industry: Energy Background: Due to the ever flocculating camp numbers (as low as 15 to 50 ep), the process of converting the BOD and Nitrogen loadings placed on the plant was a ...

ByEcofarmer Australia


EBS and SENTRY demonstrate real-time monitoring to detect Black Liquor discharge events

EBS and SENTRY demonstrate real-time monitoring to detect Black Liquor discharge events

Black liquor spills from the process can subject a downstream wastewater treatment system to periods of upset conditions and could potentially push the total BOD loading beyond the aeration capacity leading to potential permit violations. While these accidental spills by nature are impossible to predict, being able to immediately identify a change in ...

BySENTRY™ Water Technologies Inc.


Reinbeck, Iowa; SBR - Sequencing Batch Reactor - Case Study

Reinbeck, Iowa; SBR - Sequencing Batch Reactor - Case Study

” His firm had previous experience with SBR at five locations, and sought a manufacturer who could provide for a design dry weather flow of 0.3 MGD; wet weather fow of 0.73 MGD; maximum day of 1.75 MGD, and peak hour of 4.43 MGD. Design loadings were 464 lbs. BOD/day and 70 lbs. TKN/day. Design limits were set at CBOD, 25 mg/L average; TSS, 30 mg/L ...

ByFluidyne Corporation


RUŽOMBEROK Industrial WWTP - Case Study

RUŽOMBEROK Industrial WWTP - Case Study

The local WWTP is built for 600,000 P.E. (BOD load; 700,000 P.E. hydr.). More than 95% of organic load comes from the local paper mill (Mondi SCP, a.s.). ...

ByAquaconsult Anlagenbau GmbH


Improved Treatment in a Facultative Lagoon System - Case Study

Improved Treatment in a Facultative Lagoon System - Case Study

Topics: wastewater, facultative, lagoon, pond, DO distribution, odor mitigation, SolarBee floating wastewater mixers System Overview: Wastewater influent to this system consists of ~50% municipal from the City and ~50% industrial from a local candy manufacturer. This is a 3-cell facultative lagoon system covering a total of 102 surface acres. Water enters the system at Cell 1 then flowing ...

ByIxom Watercare


Project Background & Challenges, Wilmington, Vt Case Study

Project Background & Challenges, Wilmington, Vt Case Study

The WWTP in Wilmington was looking to reduce Total Suspended Solids (TSS) by 60% and Biochemical Oxygen Demand (BOD) by 30% in order to meet incoming water quality regulalations. However, in order to meet these objectives, they faced challenges in terms of both space and budget. The Nexom Answer After exploring options, the engineers in WIlmington turned to EcoBELT™, a ...

ByNexom - Axius Water


Containerized MBR Plant for a motorway station in Austria - Case study

Containerized MBR Plant for a motorway station in Austria - Case study

The key factor in the choosing AQQA® for this project was the fact that the load of BOD, COD and Ammonia is high but nevertheless the membrane filter must perform without maintenance on site. ...

ByWeise Water GmbH


A Return on Investment with Bio-Augmentation

A Return on Investment with Bio-Augmentation

Several years ago we updated our town’s wastewater treatment system to a 100,000 GPD SBR, a nice size plant for our town to grow into. Our average BOD influent load is about 250 to 300 mg/l. Most of our customers are residential, and all of them exhibit the common traits of in-home chefs that we are known for in this part of the country. ...

ByReliant Water Technologies


Organic matter degradation in a greywater recycling system using a multistage moving bed biofilm reactor (MBBR)

Organic matter degradation in a greywater recycling system using a multistage moving bed biofilm reactor (MBBR)

The results also showed that the average loading rate entering the system was 3.7 kg COD/d, while the removal rate was 3.4 kg COD/d in a total bioreactor volume of 11.7 m³. In terms of BOD, the loading rate was 2.8 kg BOD/d and it was almost totally removed. This system requires little space (0.15 m²/person) and maintenance work ...

ByIWA Publishing


Performance evaluation of a large sewage treatment plant in Brazil, consisting of an upflow anaerobic sludge blanket reactor followed by activated sludge

Performance evaluation of a large sewage treatment plant in Brazil, consisting of an upflow anaerobic sludge blanket reactor followed by activated sludge

The results highlight the good overall performance of the system, with high mean removal efficiencies: BOD (biochemical oxygen demand) (94%), COD (91%), ammonia (72%) and total suspended solids (92%). ...

ByIWA Publishing


Good Preparation and Planning Reduces Wastewater Headaches Associated with Production Outages

Good Preparation and Planning Reduces Wastewater Headaches Associated with Production Outages

Staggering machine shutdowns and tank cleaning dramatically control both hydraulic and BOD loading to the wastewater system, avoiding most serious problems during this part of the outage. But even with the best controls, BOD loading nearly always increases and can overload the existing biological population. ...

ByEnvironmental Business Specialists, LLC


TOTALOX Odor Eliminator: The Two Step Treatment in One Package - Case Study

TOTALOX Odor Eliminator: The Two Step Treatment in One Package - Case Study

Collection system conditions are usually perfect for the anaerobic bacteria to produce sulfides: Sufficient organic loading (BOD) Low oxygen levels (DO, ORP) Warm temperatures Unlimited dissolved sulfate Gravity lines can produce sulfides, but pressure mains and surcharged gravity sewers almost always create sulfides because they flow full all of the ...

ByCarus Corporation


Beyond the barriers of water reuse

Beyond the barriers of water reuse

Beyond these main drivers, a sustainable MBR system also leads to the most accurate type of design because it considers various parameters such as flows, biochemical oxygen demand (BOD), total kjeldahl nitrogen (TKN) loads, the relationship among BOD, TKN, and alkalinity, temperature, plus the relationship among various unit processes. ...

ByBioMicrobics, Inc


Huntington wastewater treatment plant case study

Huntington wastewater treatment plant case study

Energy consumption per pound of nitrogen removed is down by 26%. Influent BOD and total suspended solids (TSS) load is down by 27% and 20%, respectively. ...

ByIn-Pipe Technology LLC


Case study - Daphne utilities water reclamation facility

Case study - Daphne utilities water reclamation facility

More than that, loading reductions have cut back aerator maintenance and lowered energy consumption of blowers. ...

BySalsnes Filter


Bioaugmentation In Sewer Network Reduces Sludge Production

Bioaugmentation In Sewer Network Reduces Sludge Production

By increasing rbCOD through hydrolysis of the hydrolysable substrate, it is possible to reduce the influent load (i.e., TSS, COD, BOD, TKN) entering the WWTP through microbial processes. ...

ByIn-Pipe Technology LLC


Nation’s Largest Tank Barge Company case study

Nation’s Largest Tank Barge Company case study

The Problem: The Nation’s largest tank barge company is a centralized treatment facility that receives oily wastewater from barges and ships that transport oil and petroleum products. The wastewater is highly loaded with BOD, COD, TSS and oil and they were seeking a direct discharge permit. ...

ByBioprocessH2O

  • Previous
  • Next
Need help finding the right suppliers?Try XPRT Sourcing. Let the XPRTs do the work for you
Back to top
About XPRT Media

XPRT is a global industry marketplace and information resource. Online product catalogs, news, articles, events, publications & more.


  • FAQs
  • Company sitemap
  • Category sitemap
XPRT is part of XPRT Media All Rights Reserved.
Terms
Privacy
  • XPRT RSS List
Our sites:
Environmental XPRT
Agriculture XPRT
Energy XPRT
Medical XPRT