Refine by
Cod Control Articles & Analysis
436 articles found
This stratification supports stable performance under varying conditions. In high-rate systems, controlled upflow velocities create a fluidized bed that maintains constant contact between wastewater and biomass, while allowing lighter granules to be displaced and retained by the heavier granules. ...
A large-scale dairy farm in West Java, Indonesia, houses approximately 6,000 cows and generates 250-300 m³ of wastewater per day from dairy manure and grass silage. Its wastewater treatment process includes two biogas digesters with a combined volume of 7,000 m³. Despite stable operation, the system experienced limited COD removal efficiency (50-60%) and high hydrogen sulfide (H2S) ...
How our in-house pilot studies replicate field conditions to generate meaningful methane data. In a previous blog we discussed some of the pros and cons of BMP studies on anaerobic digesters. While they’re excellent for showing how much methane can be produced from a food substrate, they have less utility as a representative site study and will only work well in some cases. The best-case ...
COD in wastewater, short for Chemical Oxygen Demand, is one of the most important indicators of organic pollution in both domestic and industrial effluents. But how is this pollution removed efficiently and sustainably? The answer lies in nature’s tiniest engineers: microorganisms. In this article, we’ll explore how microorganisms break down COD, the biochemical steps involved, and ...
ByYASA ET
The maximum temperature of the drying room is set to 110°C, the temperature rises slowly, and the drying time is 6-8 hours to make the green body fully dry and the moisture content is controlled below 1.0%.4. Surface spraying: The dried green body enters the automatic spray drying line to complete the surface spraying. ...
Dairy processors face a significant challenge: treating wastewater efficiently and affordably. This wastewater, a byproduct of processes from cheese making to yogurt production, contains milk, whey, cleaning agents, and more. Effective dairy wastewater treatment plants are essential for water management and minimizing environmental impact. Dairy industry wastewater treatment systems are complex ...
Pitfalls to steer clear of and best practices to follow to avoid costly missteps and regulatory headaches In the realm of waste management and biogas production through anaerobic digestion, understanding the unique characteristics and requirements of each project is crucial. Missteps can lead to inefficiencies, higher costs, and compliance issues. Here we explore common pitfalls and provide ...
This organization is a global, high precision metrology and healthcare technology group. They are located in Pune, India. They design, develop and deliver solutions and systems that provide unparalleled precision, control and reliability. They are also a world leader in the field of additive manufacturing, where they design and produce industrial machines which ‘print' parts from metal ...
The presence of Fats, Oil, and Grease (FOG) in industrial processing wastewater or hotel industries can cause all kinds of problems in biological wastewater treatment systems onsite and in public sewage treatment facilities. It is, therefore, essential to reduce, if not remove FOG completely, in primary treatment then manufacturing industries, hotel industries, and societies have to experience ...
With a presence in 138 countries on six continents, pharma company is now the world’s largest integrated supplier of solid dosage products and services – providing hard-shell capsules, film and foil barrier solutions. Founded in Mumbai, India in 1961,now serves pharmaceutical companies all over the world, touching almost every aspect of solid dosage ...
Understanding Advanced Oxidation Processes The magic of advanced oxidation processes (AOPs) in wastewater treatment lies in their ability to transform harmful substances into harmless ones. Picture them as tiny, diligent workers who scrub your water clean. AOPs employ three superheroes: reactive oxygen (ROS), singlet oxygen and hydroxyl radicals. These created compounds are some of the ...
By operating in a environmental critical Area, the customer asked us to evaluate the ELECTROCOAGULATION SYSTEM for the COD REMOVAL and to propose a total ECO FRIENDLY TREATMENT without use of ...
The customer asked us to evaluate the ELECTROCOAGULATION SYSTEM for the COD and smells removal to be able to drain the treated water into the sewer ...
The benefits of real-time monitoring for aeration in wastewater include; Energy savings by optimizing the aeration rate to current water quality conditions Improved efficiency for organics removal Optimized aeration for the nitrification/denitrification process CONTROLLING AERATION Currently most control mechanisms for aeration systems rely on measuring DO in ...
Electrocoagulation is a cost-effective method to treat and purify many kinds of waters and wastewaters. It can remove up to 95% of pollutants with minimal operational costs. How does an electrocoagulation system work? What are the most typical applications? Continue reading this article to find out. What is Electrocoagulation (EC)? Electrocoagulation (EC) is an electrochemical ...
ByYASA ET
Electrocoagulation Test Equipment Features Two sizes available: 1L and 20L Interchangeable Electrodes: Iron / Aluminium / BDD / Titanium Acrylate tank for more durability and corrosion resistance Discharge valves to control the water flow Recirculating pump for continuous treatment Electrocoagulation Test Equipment Advantages The transparent tank allows the user to clearly ...
ByYASA ET
Ceramic Microfiltration and Reverse Osmosis System Installation The video and images on this page showcase how Kemco Systems and Arrow Linen Supply partnered together to meet new county wastewater discharge compliance requirements. Arrow Linen Supplies Chief Engineer, Bob Boyle, speaks with Kemco’s Regional Sales Manager, Rick Warren, about his projects needs and why they chose Kemco. ...
Using Anaerobic + OxyShark® High-Purity Oxygen, Fixed-Film Bioreactor. OxyShark® Water Reclamation Solutions was commissioned to accomplish two goals for a landfill gas production ...
According to my observation, the return system of the second settling tank is normal, and the sludge sedimentation in the second settling tank is basically returned). The COD of the inlet water is not very high. The COD of the secondary effluent is below 60mg/l (should be very good), and the entire biochemical system is very normal. ...
The aerobic tank is a structure that maintains the dissolved oxygen content suitable for the growth and reproduction of aerobic microorganisms through aeration and other measures to treat pollutants in the water. The function of the aerobic tank is to allow the activated sludge to perform aerobic respiration, further decompose organic matter into inorganic matter, and remove pollutants. ...