As winter melts into spring, environmental field teams gear up for one of the busiest times of the year: the spring sampling season. With snowmelt runoff, rising groundwater levels, and increased mobility in field conditions, spring is a critical window for collecting representative groundwater samples—especially in regions impacted by agricultural runoff or legacy contamination. A recent ...
In today’s world, precision and cleanliness are critical in industries like pharmaceuticals and biotechnology. Among the many tools used to maintain strict cleanliness standards, viable air samplers stand out as a key player. But why are these devices so essential? Let’s dive into the ...
Airborne Particle Counters (APCs) play a critical role in monitoring and maintaining the cleanliness of environments where air purity is essential, such as cleanrooms. There are two fundamental types of APCs: portable and fixed-point remote. Each type has unique features and applications, making them suitable for various scenarios in contamination control. Portable APCs are self-contained units ...
Airborne Particle Counters (APCs) play a critical role in monitoring and maintaining the cleanliness of environments where air purity is essential, such as cleanrooms. There are two fundamental types of APCs: portable and fixed-point remote. Each type has unique features and applications, making them suitable for various scenarios in contamination control. Portable APCs are self-contained units ...
Field Test Study Conducted in Association with The University of ...
By utilising water level monitoring systems, it is much easier to rapidly deploy countermeasures in the event that levels become too high or low. Water level loggers feature highly sensitive pressure sensors which can detect the smallest of changes to water level and can send alerts to preferred contacts alerting them to the situation. ...
This unit combines high sensitivity/selectivity, contactless hot wet measurement with low-cost of ownership, continuous digital sensor status and diagnostic monitoring. The module provides a quantitative and qualitative measurement that requires only rudimentary packaging and sample preparation. Axetris’s LGD module featuring a low-volume, ...
The MVX‐7100 L Workstation when paired with a DS‐5 total consumption nebulizer creates a paradigm shift in ICP‐MS sample introduction. It is a long overdue tool for trace element researchers wanting to measure elements at trace levels in microliter sized samples. ...
Low-flow sampling 2. Low-flow with parameter stabilisation then sampling 3. ...
Geotech low flow groundwater analysis equipment has enabled quick and easy access to samples at 2m intervals down a 28m screen in deep boreholes. ...
This could lead to unrepeatable measurements if these parameters are not controlled, so this method cannot be recommended for long term monitoring of flow rates over the life of the landfill. Suppose now that the flow measurement device incorporates a restriction to gas flow. ...
Being far less accessible to monitor in situ than an estuary, river, reservoir or lake, it is much more difficult to maintain quality assured sample integrity as it is retrieved from boreholes. New technology, techniques, experience pioneered in the U.S. and modern information exchange means low-flow groundwater sampling is ...
The MVX-7100 Workstation when paired with a DS-5 total consumption nebulizer creates a paradigm shift in ICP-MS sample introduction. It is a long overdue tool for trace element researchers wanting to measure elements at trace levels in microliter sized samples. ...
This means faster response, even with flame arresters installed." Fuller goes on, "The flow path through the WDG-V was completely redesigned, so it provides the fastest response of any extractive combustion gas analyzer, and it has the ability to predict a pending sensor failure and monitor flow characteristics to the sample cell." The ...
Measurements with multi-stage cascade impactors are used to determine the size distribution of particles in gas streams. Because they work with low gas flows, the sampling time is unacceptable long. Therefore, the University of Duisburg and the North Rhine Westphalia State Environment Agency developed a three stage impactor (“GMU Johnas ...
Either a multi-point sample assembly with unshrouded sharp-edged nozzles operated isokinetically or a single shrouded probe operated isokinetically or at a constant sample flow rate can be used. ...
The Intellisondes at these sites monitored free chlorine, temperature, pH, conductivity, turbidity and flow, at fifteen minute sampling intervals. The solid-state free chlorine sensor in the Intellisonde employs electrochemical technology to provide accurate data without the need for reagents or other consumables. ...
Quick and easy access in deep wells Geotech low flow groundwater analysis equipment has enabled quick and easy access to samples at 2m intervals down a 28m screen in deep boreholes. ...
This article tells you how to perform low flow groundwater sampling using a portable, surface-mounted pump with no decontamination required before each use and no chance of cross contamination between wells. ...
In each well, after the water samples have been are taken, the pumping tube is stored in the well for use during the next sampling event. ...