flame-ionization Downloads
106 downloads found
Premium
Automatic Thermal Desorption-Gas chromatography equipped with flame ionization detector (AUTO-TD-GC-FID) is the standard method for the monitoring of volatile and semi-volatile hydrocarbons. ...
Premium
EXPERTS IN GAS ANALYSIS WWW.CHROMATOTEC.COMTSP C24Chromatotec® is specialised in VOC, Sulfur and permanent gases analysis at trace and ultra trace levels (ppm, ppb, ppt).Please visit our website for more details.CHROMATHCMonitoring and analysis of Methane and Non-Methane Total Hydrocarbons (NMTHC) by flame ionisation detectionGAS ANALYZER GC 866Updated: July 2013Model: ...
Premium
Total Hydrocarbon (NMTHC) analysis by autoGC with Flame Ionisation Detection ...
The Gasmet Flame Ionization Detector (GFID) is designed for continuous total hydrocarbon (THC) measurements. ...
Premium
CHROMA THC Direct Methane and Non-Methane Total Hydrocarbon (NMTHC) analysis by autoGC with Flame Ionisation Detection ...
The flame ionization detector (FID) is a widely used detector in gas chromatography. ...
The Model 112 Analyzers are reliable, flexible and versatile instruments based on photoionization (PID) or flame ionization (FID) detectors for the measurement of volatile organic compounds (VOCs). ...
The FID is a high specification Flame Ionization Detector (FID) based analyzer that provides a robust and high accuracy solution to trace Total Hydrocarbon (THC) measurements, ensuring gas stream inflammibility levels are closely ...
DETECTORSFlame Ionization Detector - FIDThe Flame Ionization Detector responds to any molecule with a carbon-hydrogen bond, but its responseis either poor or nonexistent to compounds such as H2S, CCl4, or NH3. ...
Premium
Application: Cycle duration: 40 minutes in standard Purge support: “Purge” - Extraction of VOC from water with ultra-high purity Nitrogen (Nitroxychrom) - Sample: VOC in water (502.2 standard) - Water sample volume: 5 ml in standard - Sampling duration: 11 minutes airmoVOC C6-C12: “Trap” - Carrier gas: ultra-high purity Hydrogen (Hydroxychrom) - Detector: Flame ...
Fast response time (T90 in less than 2 seconds). High reliability and stability in time. Ex Proof and EN 1539 certifications. Low management costs. Single/multipoint monitoring, heating up to 200°C. Wall or rack mounting and outdoor installation. ...
Peak’s innovative design has also been proven to be more cost effective and user friendly compared to similar instruments. ir Model # 920-226 Flame Ionization Detector (FID) Matrix Gas: Nitrous Oxide Fields of Application: The FID model # 920-226 is the ideal solution for the detection of Methane & Carbon Dioxide compounds. ...
Peak’s innovative design is proven to be more cost-effective and user-friendly compared to similar instruments, making Peak your number one GC choice. ir Model # 920-210 Flame Ionization Detector (FID) Matrix Gas: Inert Fields of Application: The FID model # 920-210 is the ideal solution for the detection of Total Hydrocarbon & Carbon Dioxide compounds. ...
Peak’s innovative design is proven to be more cost-effective and user-friendly compared to similar instruments, making Peak your number one GC choice. ir Model # 920-220 Flame Ionization Detector (FID) Matrix Gas: Oxygen Fields of Application: The FID model # 920-220 is the ideal solution for the detection of Total Hydrocarbon & Carbon Dioxide compounds. ...
SHED-FIDDatasheet HC-AnalysatorMini/Micro-SHEDProduct descriptionThe Flame Ionization Detector 2000MP is analyzing hydrocarbons in SHED-chambers of different dimensions. ...
.¦ BenefitsThe FIDAMAT 6 gas analyzer is distinguished by its wide range of applications:• In the presence of up to 100 % H2O vapor• With high-boiling components (up to 200 °C)• In the presence of corrosive gases (with preliminary filter)The FIDAMAT 6 exhibits:• Extremely low cross-sensitivity to interfering gases• Low consumption of combustion air• Low influence of oxygen on measured valueThe ...
The Model 650 FID is a high-temperature flame ionization sensor that continuously measures total hydrocarbon concentrations. Control Instruments' proprietary FID design assures an accurate and linear response. A carefully metered pilot flame incinerates the sample. The resulting ionized carbon passes through an electrical field, creating a proportional current flow. An electrometer measures the ...
The SERVOPRO FID is a Flame Ionization Detector based analyzer designed to assure safe operation within Cryogenic Air Separation plants by assuring the level of Total Hydrocarbons (THC) is maintained below inflammable limits as well as provide quality control in pure O2, N2, Ar, and Air. ...
Premium
It encompasses a specific trap to concentrate the sample, a column for separation of chemicals and two detectors: a new micro flame ionization detector (FID) and a mass spectrometer for quantification and identification respectively. ...
Designed and manufactured specifically for industrial use, the Model 650 flame ionization detector (FID) is the ideal choice for process and stack monitoring in a wide range of applications. ...